Product Features

  • Automatically positioned two-position two-way solenoid valve, with fast and sensitive action.
  • Wide operating pressure range, with high-pressure (H) and standard types available for selection.
  • Compact structure, small size, light weight, and easy installation and disassembly.
  • The valve body is made of SUS304 stainless steel, and the electromagnetic coil has a heat resistance classification of Grade H. The seal material is PTFE (Teflon), making it suitable for a variety of working media, especially for high-temperature water and steam.
  • The coil has a protection class of IP65, with electrical connection options of direct lead wire or DIN connector.

Specifications

Model No. Port Size [Note 1] Orifice Dia. (mm) Cv Value Effective Area (mm²) Weight (g) [Note 2] Max. Operating Pressure Max. Proof Pressure
MPa psi MPa psi
2LH030 -06 PT1/8 2.0 0.18 3.0 300 2.0 300 3.0 450
-08 PT1/4 290
2L030 -06 PT1/8 3.0 0.33 6.0 300 1.0 150
-08 PT1/4 290
2LH050 -10 PT3/8 4.0 0.55 10.0 600 2.0 300
-15 PT1/2 590
2L050 -10 PT3/8 5.0 0.83 15.0 600 1.0 150
-15 PT1/2 590
Note 1: G, NPT threads are available.
Note 2: The weight listed is for the DIN connector type. The lead wire type for the 2L030 series is 10g lighter, and for the 2L050 series, it is 20g lighter.

Product Ordering Code

Position Description Options & Values
1 Model Code
  • 2L: 2/2 Way Direct Acting Normally Closed Solenoid Valve
2 Pressure Type
  • H: High-pressure type
  • Blank: Standard type
3 Series Code
  • 030: 030 Series
  • 050: 050 Series
4 Port Size
  • 06: 1/8"
  • 08: 1/4"
  • 10: 3/8"
  • 15: 1/2"
5 Coil Voltage
  • A: AC220V
  • B: DC24V
  • C: AC110V
  • E: AC24V
  • F: DC12V
6 Connection Type
  • Blank: DIN connector type
  • I: Lead wire type [Note 1]
7 Thread Code
  • Blank: PT thread
  • G: G thread
  • T: NPT thread
Note 1: The standard length for the lead wire type is 0.5m.
  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015B Airtac 2L150: 2 Way Solenoid Valve - 2L15015B - 2

    Airtac 2L series: two-way fluid solenoid valve - 2L15015B

    Specifications: 2L15015B is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects PT1/2; voltage code B selects DC24V; electrical entry is terminal connector. The omitted thread suffix selects PT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015B will be supplied as 2LA15015B (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015B in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — PT1/2 Voltage code B — DC24V Electrical-entry code Omitted — terminal Thread code Omitted — PT Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 675 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage DC24V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±10% Supply frequency DC; frequency is not applicable. Power consumption 6.5 W Catalog temperature rise 30°C Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 77 mm AB — body span AB 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P PT1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L030-08: 2 Way Solenoid Valve - 2L03008BT Airtac 2L030-08: 2 Way Solenoid Valve - 2L03008BT - 2

    Airtac 2L series: two-way fluid solenoid valve - 2L03008BT

    Specifications: 2L03008BT is an AirTAC 2L 2/2-way direct acting, normally closed solenoid valve. the omitted pressure code specifies the standard-pressure branch; 030 identifies the size series; port code 08 selects NPT1/4; voltage code B selects DC24V; electrical entry is terminal connector. Thread suffix T selects NPT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L03008BT will be supplied as 2LA03008BT (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L03008BT in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The coil acts directly on the valve mechanism. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way direct acting, normally closed Size code 030 — series size, not an orifice dimension Pressure-condition code Omitted — standard pressure Port-size code 08 — NPT1/4 Voltage code B — DC24V Electrical-entry code Omitted — terminal Thread code T — NPT Technical Specifications Parameter Details Actuation and normal state Direct acting; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 3 mm Flow coefficient Cv 0.33 Effective flow area 6 mm² Operating pressure differential Maximum differential: 1 MPa. The specification table does not separately state a minimum differential. Proof pressure 3 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 290 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage DC24V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±10% Supply frequency DC; frequency is not applicable. Power consumption 6.5 W Catalog temperature rise 30°C Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 2 (printed page 211). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 72.5 mm AB — body span AB 40 mm B — drawing width B 29.5 mm C — drawing height C 71 mm D — drawing dimension D 20 mm E — drawing dimension E 49 mm F — drawing dimension F 43.5 mm G — drawing dimension G 10 mm K — bracket hole diameter K 5.3 mm KA — bracket hole spacing KA 40 mm P — fluid port thread P NPT1/4 PA — drawing dimension PA 10 mm Q — mounting screw thread Q M5 QA — drawing dimension QA 16 mm The drawing marks two Q mounting threads and two ØK bracket holes. The bracket is optional; its illustrated footprint is not the valve-only envelope. Use the selected port thread shown above; PT, G and NPT are different ordering choices. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 3 mm orifice, Cv 0.33 and 6 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” with downstream pressure P2 in MPa, upstream-pressure curves P1, subsonic/sonic regions and a critical-pressure boundary. Its flow axis is labelled kg/h, with separate scales for Ø2, Ø3, Ø4 and Ø5 mm orifices. The water chart plots Q in L/min against ΔP=P1−P2 in MPa, with curves for those four orifices. The water-chart marked scale runs from 0.001 to 0.6 MPa and 0.1 to 40 L/min; the pressure-chart P2 scale runs from 0 to 1.0 MPa. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L030 (terminal). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Airtight ring 3 Spring 4 Spring 5 O-ring 6 Fixed cap 7 Fixed plate 8 Movable core 9 Coil assembly 10 Washer 11 E clip 12 Connector 13 Washer 14 Screw Mounting Accessories and Selection The catalog accessory selection identifies F-2S030LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L030-06: 2 Way Solenoid Valve - 2L03006BT - 5 Airtac 2L030-06: 2 Way Solenoid Valve - 2L03006BT

    Airtac 2L series: two-way fluid solenoid valve - 2L03006BT

    Specifications: 2L03006BT is an AirTAC 2L 2/2-way direct acting, normally closed solenoid valve. the omitted pressure code specifies the standard-pressure branch; 030 identifies the size series; port code 06 selects NPT1/8; voltage code B selects DC24V; electrical entry is terminal connector. Thread suffix T selects NPT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L03006BT will be supplied as 2LA03006BT (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L03006BT in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The coil acts directly on the valve mechanism. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way direct acting, normally closed Size code 030 — series size, not an orifice dimension Pressure-condition code Omitted — standard pressure Port-size code 06 — NPT1/8 Voltage code B — DC24V Electrical-entry code Omitted — terminal Thread code T — NPT Technical Specifications Parameter Details Actuation and normal state Direct acting; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 3 mm Flow coefficient Cv 0.33 Effective flow area 6 mm² Operating pressure differential Maximum differential: 1 MPa. The specification table does not separately state a minimum differential. Proof pressure 3 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 300 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage DC24V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±10% Supply frequency DC; frequency is not applicable. Power consumption 6.5 W Catalog temperature rise 30°C Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 2 (printed page 211). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 72.5 mm AB — body span AB 40 mm B — drawing width B 29.5 mm C — drawing height C 71 mm D — drawing dimension D 20 mm E — drawing dimension E 49 mm F — drawing dimension F 43.5 mm G — drawing dimension G 10 mm K — bracket hole diameter K 5.3 mm KA — bracket hole spacing KA 40 mm P — fluid port thread P NPT1/8 PA — drawing dimension PA 10 mm Q — mounting screw thread Q M5 QA — drawing dimension QA 16 mm The drawing marks two Q mounting threads and two ØK bracket holes. The bracket is optional; its illustrated footprint is not the valve-only envelope. Use the selected port thread shown above; PT, G and NPT are different ordering choices. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 3 mm orifice, Cv 0.33 and 6 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” with downstream pressure P2 in MPa, upstream-pressure curves P1, subsonic/sonic regions and a critical-pressure boundary. Its flow axis is labelled kg/h, with separate scales for Ø2, Ø3, Ø4 and Ø5 mm orifices. The water chart plots Q in L/min against ΔP=P1−P2 in MPa, with curves for those four orifices. The water-chart marked scale runs from 0.001 to 0.6 MPa and 0.1 to 40 L/min; the pressure-chart P2 scale runs from 0 to 1.0 MPa. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L030 (terminal). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Airtight ring 3 Spring 4 Spring 5 O-ring 6 Fixed cap 7 Fixed plate 8 Movable core 9 Coil assembly 10 Washer 11 E clip 12 Connector 13 Washer 14 Screw Mounting Accessories and Selection The catalog accessory selection identifies F-2S030LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L030-08: 2 Way Solenoid Valve - 2L03008E Airtac 2L030-08: 2 Way Solenoid Valve - 2L03008E - 2

    Airtac 2L series: two-way fluid solenoid valve - 2L03008E

    Specifications: 2L03008E is an AirTAC 2L 2/2-way direct acting, normally closed solenoid valve. the omitted pressure code specifies the standard-pressure branch; 030 identifies the size series; port code 08 selects PT1/4; voltage code E selects AC24V; electrical entry is terminal connector. The omitted thread suffix selects PT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L03008E will be supplied as 2LA03008E (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L03008E in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The coil acts directly on the valve mechanism. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way direct acting, normally closed Size code 030 — series size, not an orifice dimension Pressure-condition code Omitted — standard pressure Port-size code 08 — PT1/4 Voltage code E — AC24V Electrical-entry code Omitted — terminal Thread code Omitted — PT Technical Specifications Parameter Details Actuation and normal state Direct acting; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 3 mm Flow coefficient Cv 0.33 Effective flow area 6 mm² Operating pressure differential Maximum differential: 1 MPa. The specification table does not separately state a minimum differential. Proof pressure 3 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 290 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC24V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 10 VA at 50 Hz; 8 VA at 60 Hz Catalog temperature rise 35°C at 50 Hz; 30°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 2 (printed page 211). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 72.5 mm AB — body span AB 40 mm B — drawing width B 29.5 mm C — drawing height C 71 mm D — drawing dimension D 20 mm E — drawing dimension E 49 mm F — drawing dimension F 43.5 mm G — drawing dimension G 10 mm K — bracket hole diameter K 5.3 mm KA — bracket hole spacing KA 40 mm P — fluid port thread P PT1/4 PA — drawing dimension PA 10 mm Q — mounting screw thread Q M5 QA — drawing dimension QA 16 mm The drawing marks two Q mounting threads and two ØK bracket holes. The bracket is optional; its illustrated footprint is not the valve-only envelope. Use the selected port thread shown above; PT, G and NPT are different ordering choices. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 3 mm orifice, Cv 0.33 and 6 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” with downstream pressure P2 in MPa, upstream-pressure curves P1, subsonic/sonic regions and a critical-pressure boundary. Its flow axis is labelled kg/h, with separate scales for Ø2, Ø3, Ø4 and Ø5 mm orifices. The water chart plots Q in L/min against ΔP=P1−P2 in MPa, with curves for those four orifices. The water-chart marked scale runs from 0.001 to 0.6 MPa and 0.1 to 40 L/min; the pressure-chart P2 scale runs from 0 to 1.0 MPa. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L030 (terminal). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Airtight ring 3 Spring 4 Spring 5 O-ring 6 Fixed cap 7 Fixed plate 8 Movable core 9 Coil assembly 10 Washer 11 E clip 12 Connector 13 Washer 14 Screw Mounting Accessories and Selection The catalog accessory selection identifies F-2S030LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L series: two-way fluid solenoid valve - 2L25025B Airtac 2L series: two-way fluid solenoid valve - 2L25025B - 2

    Airtac 2L series: two-way fluid solenoid valve - 2L25025B

    Specifications: 2L25025B is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 250 identifies the orifice-size branch; port code 25 selects PT1; voltage code B selects DC24V; electrical entry is terminal connector. The omitted thread suffix selects PT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L25025B will be supplied as 2LA25025B (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L25025B in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 250 — 25 mm orifice Port-size code 25 — PT1 Voltage code B — DC24V Electrical-entry code Omitted — terminal Thread code Omitted — PT Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 25 mm Flow coefficient Cv 12.50 Effective flow area 220 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 1120 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage DC24V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±10% Supply frequency DC; frequency is not applicable. Power consumption 6.5 W Catalog temperature rise 30°C Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 81 mm AB — body span AB 92 mm B — drawing width B 59 mm BA — port-side span BA 40.5 mm C — drawing height C 124 mm D — drawing dimension D 95 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 80 mm EC — drawing dimension EC 44.5 mm F — drawing dimension F 36 mm P — fluid port thread P PT1 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. Drawing check required: the source table lists A=81 mm and AB=92 mm for this terminal version. These values are reproduced exactly, although the drawing makes their relationship unclear. Confirm the approved drawing before using this combination for installation or interchangeability. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 25 mm orifice, Cv 12.50 and 220 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S250LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

    $154.40

  • Airtac 2L320-32: 2 Way Solenoid Valve - 2L32032AG Airtac 2L320-32: 2 Way Solenoid Valve - 2L32032BG - 2

    Airtac 2L series: two-way fluid solenoid valve - 2L32032BG

    Specifications: 2L32032BG is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 320 identifies the orifice-size branch; port code 32 selects G1 1/4; voltage code B selects DC24V; electrical entry is terminal connector. Thread suffix G selects G threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L32032BG will be supplied as 2LA32032BG (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L32032BG in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 320 — 35 mm orifice Port-size code 32 — G1 1/4 Voltage code B — DC24V Electrical-entry code Omitted — terminal Thread code G — G Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 35 mm Flow coefficient Cv 23.00 Effective flow area 420 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 2700 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage DC24V Electrical entry terminal connector Coil family listed for this valve CDA170 Supply tolerance ±10% Supply frequency DC; frequency is not applicable. Power consumption 12 W Catalog temperature rise 40°C Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 125 mm AB — body span AB — B — drawing width B 80 mm BA — port-side span BA 52 mm C — drawing height C 154.5 mm D — drawing dimension D — E — drawing dimension E — EA — drawing dimension EA — EB — drawing dimension EB — EC — drawing dimension EC — F — drawing dimension F — P — fluid port thread P G1 1/4 The catalog states that the 320, 400 and 500 series have no mounting accessories. D, E, EA, EB, EC and F are therefore not listed for this branch. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 35 mm orifice, Cv 23.00 and 420 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog states that the 320, 400 and 500 series have no mounting accessories. Do not assume that a bracket shown for a smaller body is supplied or compatible. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

    $321.68

  • Airtac 2L030-06: 2 Way Solenoid Valve - 2L03006B Airtac 2L030-06: 2 Way Solenoid Valve - 2L03006B - 2

    Airtac 2L series: two-way fluid solenoid valve - 2L03006B

    Specifications: 2L03006B is an AirTAC 2L 2/2-way direct acting, normally closed solenoid valve. the omitted pressure code specifies the standard-pressure branch; 030 identifies the size series; port code 06 selects PT1/8; voltage code B selects DC24V; electrical entry is terminal connector. The omitted thread suffix selects PT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L03006B will be supplied as 2LA03006B (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L03006B in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The coil acts directly on the valve mechanism. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way direct acting, normally closed Size code 030 — series size, not an orifice dimension Pressure-condition code Omitted — standard pressure Port-size code 06 — PT1/8 Voltage code B — DC24V Electrical-entry code Omitted — terminal Thread code Omitted — PT Technical Specifications Parameter Details Actuation and normal state Direct acting; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 3 mm Flow coefficient Cv 0.33 Effective flow area 6 mm² Operating pressure differential Maximum differential: 1 MPa. The specification table does not separately state a minimum differential. Proof pressure 3 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 300 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage DC24V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±10% Supply frequency DC; frequency is not applicable. Power consumption 6.5 W Catalog temperature rise 30°C Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 2 (printed page 211). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 72.5 mm AB — body span AB 40 mm B — drawing width B 29.5 mm C — drawing height C 71 mm D — drawing dimension D 20 mm E — drawing dimension E 49 mm F — drawing dimension F 43.5 mm G — drawing dimension G 10 mm K — bracket hole diameter K 5.3 mm KA — bracket hole spacing KA 40 mm P — fluid port thread P PT1/8 PA — drawing dimension PA 10 mm Q — mounting screw thread Q M5 QA — drawing dimension QA 16 mm The drawing marks two Q mounting threads and two ØK bracket holes. The bracket is optional; its illustrated footprint is not the valve-only envelope. Use the selected port thread shown above; PT, G and NPT are different ordering choices. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 3 mm orifice, Cv 0.33 and 6 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” with downstream pressure P2 in MPa, upstream-pressure curves P1, subsonic/sonic regions and a critical-pressure boundary. Its flow axis is labelled kg/h, with separate scales for Ø2, Ø3, Ø4 and Ø5 mm orifices. The water chart plots Q in L/min against ΔP=P1−P2 in MPa, with curves for those four orifices. The water-chart marked scale runs from 0.001 to 0.6 MPa and 0.1 to 40 L/min; the pressure-chart P2 scale runs from 0 to 1.0 MPa. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L030 (terminal). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Airtight ring 3 Spring 4 Spring 5 O-ring 6 Fixed cap 7 Fixed plate 8 Movable core 9 Coil assembly 10 Washer 11 E clip 12 Connector 13 Washer 14 Screw Mounting Accessories and Selection The catalog accessory selection identifies F-2S030LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2LH030-08: 2 Way Solenoid Valve - 2LH03008BI

    Airtac 2L series: two-way fluid solenoid valve - 2LH03008BI

    Specifications: 2LH03008BI is an AirTAC 2L 2/2-way direct acting, normally closed solenoid valve. H specifies the high-pressure branch; 030 identifies the size series; port code 08 selects PT1/4; voltage code B selects DC24V; electrical entry is grommet / flying lead with a 0.5 m lead. The omitted thread suffix selects PT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2LH03008BI will be supplied as 2LAH03008BI (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2LH03008BI in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The coil acts directly on the valve mechanism. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way direct acting, normally closed Size code 030 — series size, not an orifice dimension Pressure-condition code H — high pressure Port-size code 08 — PT1/4 Voltage code B — DC24V Electrical-entry code I — grommet / flying lead, 0.5 m Thread code Omitted — PT Technical Specifications Parameter Details Actuation and normal state Direct acting; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 2 mm Flow coefficient Cv 0.18 Effective flow area 3 mm² Operating pressure differential Maximum differential: 2 MPa. The specification table does not separately state a minimum differential. Proof pressure 3 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 280 g = 290 g terminal value − 10 g grommet reduction. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage DC24V Electrical entry grommet / flying lead with a 0.5 m lead Coil family listed for this valve CLA116 Supply tolerance ±10% Supply frequency DC; frequency is not applicable. Power consumption 6.5 W Catalog temperature rise 30°C Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L grommet / flying-lead drawing, PDF page 2 (printed page 211). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 41 mm AB — body span AB 40 mm B — drawing width B 29.5 mm C — drawing height C 71 mm D — drawing dimension D 20 mm E — drawing dimension E 49 mm G — drawing dimension G 10 mm K — bracket hole diameter K 5.3 mm KA — bracket hole spacing KA 40 mm P — fluid port thread P PT1/4 PA — drawing dimension PA 10 mm Q — mounting screw thread Q M5 QA — drawing dimension QA 16 mm The drawing marks two Q mounting threads and two ØK bracket holes. The bracket is optional; its illustrated footprint is not the valve-only envelope. Use the selected port thread shown above; PT, G and NPT are different ordering choices. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 2 mm orifice, Cv 0.18 and 3 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” with downstream pressure P2 in MPa, upstream-pressure curves P1, subsonic/sonic regions and a critical-pressure boundary. Its flow axis is labelled kg/h, with separate scales for Ø2, Ø3, Ø4 and Ø5 mm orifices. The water chart plots Q in L/min against ΔP=P1−P2 in MPa, with curves for those four orifices. The water-chart marked scale runs from 0.001 to 0.6 MPa and 0.1 to 40 L/min; the pressure-chart P2 scale runs from 0 to 1.0 MPa. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L030 (terminal). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Airtight ring 3 Spring 4 Spring 5 O-ring 6 Fixed cap 7 Fixed plate 8 Movable core 9 Coil assembly 10 Washer 11 E clip 12 Connector 13 Washer 14 Screw Mounting Accessories and Selection The catalog accessory selection identifies F-2S030LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L050-15: 2 Way Solenoid Valve - 2L05015CIG

    Airtac 2L series: two-way fluid solenoid valve - 2L05015CIG

    Specifications: 2L05015CIG is an AirTAC 2L 2/2-way direct acting, normally closed solenoid valve. the omitted pressure code specifies the standard-pressure branch; 050 identifies the size series; port code 15 selects G1/2; voltage code C selects AC110V; electrical entry is grommet / flying lead with a 0.5 m lead. Thread suffix G selects G threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L05015CIG will be supplied as 2LA05015CIG (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L05015CIG in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The coil acts directly on the valve mechanism. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way direct acting, normally closed Size code 050 — series size, not an orifice dimension Pressure-condition code Omitted — standard pressure Port-size code 15 — G1/2 Voltage code C — AC110V Electrical-entry code I — grommet / flying lead, 0.5 m Thread code G — G Technical Specifications Parameter Details Actuation and normal state Direct acting; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 5 mm Flow coefficient Cv 0.83 Effective flow area 15 mm² Operating pressure differential Maximum differential: 1 MPa. The specification table does not separately state a minimum differential. Proof pressure 3 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 570 g = 590 g terminal value − 20 g grommet reduction. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC110V Electrical entry grommet / flying lead with a 0.5 m lead Coil family listed for this valve CLA170 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 25 VA at 50 Hz; 22 VA at 60 Hz Catalog temperature rise 60°C at 50 Hz; 55°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L grommet / flying-lead drawing, PDF page 2 (printed page 211). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 60 mm AB — body span AB 52 mm B — drawing width B 39 mm C — drawing height C 87 mm D — drawing dimension D 26 mm E — drawing dimension E 56 mm G — drawing dimension G 10 mm K — bracket hole diameter K 5.3 mm KA — bracket hole spacing KA 48 mm P — fluid port thread P G1/2 PA — drawing dimension PA 13 mm Q — mounting screw thread Q M5 QA — drawing dimension QA 23 mm The drawing marks two Q mounting threads and two ØK bracket holes. The bracket is optional; its illustrated footprint is not the valve-only envelope. Use the selected port thread shown above; PT, G and NPT are different ordering choices. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 5 mm orifice, Cv 0.83 and 15 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” with downstream pressure P2 in MPa, upstream-pressure curves P1, subsonic/sonic regions and a critical-pressure boundary. Its flow axis is labelled kg/h, with separate scales for Ø2, Ø3, Ø4 and Ø5 mm orifices. The water chart plots Q in L/min against ΔP=P1−P2 in MPa, with curves for those four orifices. The water-chart marked scale runs from 0.001 to 0.6 MPa and 0.1 to 40 L/min; the pressure-chart P2 scale runs from 0 to 1.0 MPa. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L030 (terminal). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Airtight ring 3 Spring 4 Spring 5 O-ring 6 Fixed cap 7 Fixed plate 8 Movable core 9 Coil assembly 10 Washer 11 E clip 12 Connector 13 Washer 14 Screw Mounting Accessories and Selection The catalog accessory selection identifies F-2S050LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2LH050-10: 2 Way Solenoid Valve - 2LH05010AG Airtac 2LH050-10: 2 Way Solenoid Valve - 2LH05010BG - 2

    Airtac 2L series: two-way fluid solenoid valve - 2LH05010BG

    Specifications: 2LH05010BG is an AirTAC 2L 2/2-way direct acting, normally closed solenoid valve. H specifies the high-pressure branch; 050 identifies the size series; port code 10 selects G3/8; voltage code B selects DC24V; electrical entry is terminal connector. Thread suffix G selects G threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2LH05010BG will be supplied as 2LAH05010BG (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2LH05010BG in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The coil acts directly on the valve mechanism. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way direct acting, normally closed Size code 050 — series size, not an orifice dimension Pressure-condition code H — high pressure Port-size code 10 — G3/8 Voltage code B — DC24V Electrical-entry code Omitted — terminal Thread code G — G Technical Specifications Parameter Details Actuation and normal state Direct acting; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 4 mm Flow coefficient Cv 0.55 Effective flow area 10 mm² Operating pressure differential Maximum differential: 2 MPa. The specification table does not separately state a minimum differential. Proof pressure 3 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 600 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage DC24V Electrical entry terminal connector Coil family listed for this valve CDA170 Supply tolerance ±10% Supply frequency DC; frequency is not applicable. Power consumption 12 W Catalog temperature rise 40°C Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 2 (printed page 211). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 89.5 mm AB — body span AB 52 mm B — drawing width B 39 mm C — drawing height C 87 mm D — drawing dimension D 26 mm E — drawing dimension E 56 mm F — drawing dimension F 51 mm G — drawing dimension G 10 mm K — bracket hole diameter K 5.3 mm KA — bracket hole spacing KA 48 mm P — fluid port thread P G3/8 PA — drawing dimension PA 13 mm Q — mounting screw thread Q M5 QA — drawing dimension QA 23 mm The drawing marks two Q mounting threads and two ØK bracket holes. The bracket is optional; its illustrated footprint is not the valve-only envelope. Use the selected port thread shown above; PT, G and NPT are different ordering choices. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 4 mm orifice, Cv 0.55 and 10 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” with downstream pressure P2 in MPa, upstream-pressure curves P1, subsonic/sonic regions and a critical-pressure boundary. Its flow axis is labelled kg/h, with separate scales for Ø2, Ø3, Ø4 and Ø5 mm orifices. The water chart plots Q in L/min against ΔP=P1−P2 in MPa, with curves for those four orifices. The water-chart marked scale runs from 0.001 to 0.6 MPa and 0.1 to 40 L/min; the pressure-chart P2 scale runs from 0 to 1.0 MPa. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L030 (terminal). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Airtight ring 3 Spring 4 Spring 5 O-ring 6 Fixed cap 7 Fixed plate 8 Movable core 9 Coil assembly 10 Washer 11 E clip 12 Connector 13 Washer 14 Screw Mounting Accessories and Selection The catalog accessory selection identifies F-2S050LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015AG Airtac 2L150: 2 Way Solenoid Valve - 2L15015BG - 2

    Airtac 2L series: two-way fluid solenoid valve - 2L15015BG

    Specifications: 2L15015BG is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects G1/2; voltage code B selects DC24V; electrical entry is terminal connector. Thread suffix G selects G threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015BG will be supplied as 2LA15015BG (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015BG in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — G1/2 Voltage code B — DC24V Electrical-entry code Omitted — terminal Thread code G — G Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 675 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage DC24V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±10% Supply frequency DC; frequency is not applicable. Power consumption 6.5 W Catalog temperature rise 30°C Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 77 mm AB — body span AB 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P G1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015C Airtac 2L150: 2 Way Solenoid Valve - 2L15015C - 2

    Airtac 2L series: two-way fluid solenoid valve - 2L15015C

    Specifications: 2L15015C is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects PT1/2; voltage code C selects AC110V; electrical entry is terminal connector. The omitted thread suffix selects PT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015C will be supplied as 2LA15015C (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015C in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — PT1/2 Voltage code C — AC110V Electrical-entry code Omitted — terminal Thread code Omitted — PT Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 675 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC110V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 10 VA at 50 Hz; 8 VA at 60 Hz Catalog temperature rise 35°C at 50 Hz; 30°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 77 mm AB — body span AB 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P PT1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac Mounting Accessory - F-2L250LB

    Airtac F-2L series: valve mounting bracket - F-2L250LB

    Specifications: F-2L250LB is the existing listing identifier for an LB-type mounting accessory associated with the 250 body-size branch. It is a mounting component, not an electrically operated valve. The supplied manufacturer catalog lists F-2S250LB for the corresponding legacy valve group; it does not list F-2L250LB as an official ordering code. Product Catalogs and Comparison Guide Download Airtac Coil and Accessories Catalog (PDF) Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Ordering-Code Verification Confirm the exact bracket before ordering. The existing listing code is retained, but its correspondence to the catalog bracket requires confirmation. The valve series update does not prove that this legacy bracket is replaced by an A-suffixed version. Parameter Details Existing listing identifier F-2L250LB Catalog legacy bracket code F-2S250LB Legacy chart application 2W / 2KW, 2S / 2KS and 2L / 2KL, corresponding 250 size branch New-generation chart code F-2WA250LB New chart application Corresponding 2LA / 2KLA 250 branch, as shown on the new accessory selection page Current status Listing-code match and supplied component require confirmation; no SKU has been renamed Function and Catalog Scope The LB accessory mounts the valve body using the optional bracket arrangement illustrated in the valve catalog. Bracket-related dimensions in those illustrations refer to the assembled installation and must not be relabelled as a fully dimensioned loose-part drawing. The source selection table lists brackets for the 030, 050, 150, 200 and 250 branches. The 320, 400 and 500 branches are shown without mounting accessories. Packing, Dimensions and Weight Parameter Details Packing components and quantity Not specified in the supplied bracket selection table Standalone bracket dimensions Not provided; confirm the matching bracket drawing Bracket material Not stated in the supplied selection table Bracket weight Not stated; no valve weight is substituted Electrical and fluid specifications Not applicable to this mounting component For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Reference Weight Estimated reference weight: 60 g. The mass reference is the DOLD listing for F-2WA250LB, which lists an item weight of 60 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. A later 2WA mounting bracket for the same nominal valve size is used only as a mass analogy; old/new bracket dimensions and interchangeability are not asserted. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac Mounting Accessory - F-2L200LB

    Airtac F-2L series: valve mounting bracket - F-2L200LB

    Specifications: F-2L200LB is the existing listing identifier for an LB-type mounting accessory associated with the 200 body-size branch. It is a mounting component, not an electrically operated valve. The supplied manufacturer catalog lists F-2S200LB for the corresponding legacy valve group; it does not list F-2L200LB as an official ordering code. Product Catalogs and Comparison Guide Download Airtac Coil and Accessories Catalog (PDF) Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Ordering-Code Verification Confirm the exact bracket before ordering. The existing listing code is retained, but its correspondence to the catalog bracket requires confirmation. The valve series update does not prove that this legacy bracket is replaced by an A-suffixed version. Parameter Details Existing listing identifier F-2L200LB Catalog legacy bracket code F-2S200LB Legacy chart application 2W / 2KW, 2S / 2KS and 2L / 2KL, corresponding 200 size branch New-generation chart code F-2WA200LB New chart application Corresponding 2LA / 2KLA 200 branch, as shown on the new accessory selection page Current status Listing-code match and supplied component require confirmation; no SKU has been renamed Function and Catalog Scope The LB accessory mounts the valve body using the optional bracket arrangement illustrated in the valve catalog. Bracket-related dimensions in those illustrations refer to the assembled installation and must not be relabelled as a fully dimensioned loose-part drawing. The source selection table lists brackets for the 030, 050, 150, 200 and 250 branches. The 320, 400 and 500 branches are shown without mounting accessories. Packing, Dimensions and Weight Parameter Details Packing components and quantity Not specified in the supplied bracket selection table Standalone bracket dimensions Not provided; confirm the matching bracket drawing Bracket material Not stated in the supplied selection table Bracket weight Not stated; no valve weight is substituted Electrical and fluid specifications Not applicable to this mounting component For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Reference Weight Estimated reference weight: 60 g. The mass reference is the DOLD listing for F-2S200LB, which lists an item weight of 60 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The catalog-shared mounting-bracket family and nominal valve size identify the mass reference. The current listing code is preserved; this mass reference does not certify an unlisted accessory code or broaden catalog fitment. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac Mounting Accessory - F-2L150LB

    Airtac F-2L series: valve mounting bracket - F-2L150LB

    Specifications: F-2L150LB is the existing listing identifier for an LB-type mounting accessory associated with the 150 body-size branch. It is a mounting component, not an electrically operated valve. The supplied manufacturer catalog lists F-2S150LB for the corresponding legacy valve group; it does not list F-2L150LB as an official ordering code. Product Catalogs and Comparison Guide Download Airtac Coil and Accessories Catalog (PDF) Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Ordering-Code Verification Confirm the exact bracket before ordering. The existing listing code is retained, but its correspondence to the catalog bracket requires confirmation. The valve series update does not prove that this legacy bracket is replaced by an A-suffixed version. Parameter Details Existing listing identifier F-2L150LB Catalog legacy bracket code F-2S150LB Legacy chart application 2W / 2KW, 2S / 2KS and 2L / 2KL, corresponding 150 size branch New-generation chart code F-2WA150LB New chart application Corresponding 2LA / 2KLA 150 branch, as shown on the new accessory selection page Current status Listing-code match and supplied component require confirmation; no SKU has been renamed Function and Catalog Scope The LB accessory mounts the valve body using the optional bracket arrangement illustrated in the valve catalog. Bracket-related dimensions in those illustrations refer to the assembled installation and must not be relabelled as a fully dimensioned loose-part drawing. The source selection table lists brackets for the 030, 050, 150, 200 and 250 branches. The 320, 400 and 500 branches are shown without mounting accessories. Packing, Dimensions and Weight Parameter Details Packing components and quantity Not specified in the supplied bracket selection table Standalone bracket dimensions Not provided; confirm the matching bracket drawing Bracket material Not stated in the supplied selection table Bracket weight Not stated; no valve weight is substituted Electrical and fluid specifications Not applicable to this mounting component For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Reference Weight Estimated reference weight: 50 g. The mass reference is the DOLD listing for F-2S150LB, which lists an item weight of 50 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The catalog-shared mounting-bracket family and nominal valve size identify the mass reference. The current listing code is preserved; this mass reference does not certify an unlisted accessory code or broaden catalog fitment. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac Mounting Accessory - F-2L050LB

    Airtac F-2L series: valve mounting bracket - F-2L050LB

    Specifications: F-2L050LB is the existing listing identifier for an LB-type mounting accessory associated with the 050 body-size branch. It is a mounting component, not an electrically operated valve. The supplied manufacturer catalog lists F-2S050LB for the corresponding legacy valve group; it does not list F-2L050LB as an official ordering code. Product Catalogs and Comparison Guide Download Airtac Coil and Accessories Catalog (PDF) Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Ordering-Code Verification Confirm the exact bracket before ordering. The existing listing code is retained, but its correspondence to the catalog bracket requires confirmation. The valve series update does not prove that this legacy bracket is replaced by an A-suffixed version. Parameter Details Existing listing identifier F-2L050LB Catalog legacy bracket code F-2S050LB Legacy chart application 2W / 2KW, 2S / 2KS and 2L / 2KL, corresponding 050 size branch New-generation chart code F-2WA050LB New chart application Corresponding 2LA / 2KLA 050 branch, as shown on the new accessory selection page Current status Listing-code match and supplied component require confirmation; no SKU has been renamed Function and Catalog Scope The LB accessory mounts the valve body using the optional bracket arrangement illustrated in the valve catalog. Bracket-related dimensions in those illustrations refer to the assembled installation and must not be relabelled as a fully dimensioned loose-part drawing. The source selection table lists brackets for the 030, 050, 150, 200 and 250 branches. The 320, 400 and 500 branches are shown without mounting accessories. Packing, Dimensions and Weight Parameter Details Packing components and quantity Not specified in the supplied bracket selection table Standalone bracket dimensions Not provided; confirm the matching bracket drawing Bracket material Not stated in the supplied selection table Bracket weight Not stated; no valve weight is substituted Electrical and fluid specifications Not applicable to this mounting component For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Reference Weight Estimated reference weight: 20 g. The mass reference is the DOLD listing for F-2S050LB, which lists an item weight of 20 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The catalog-shared mounting-bracket family and nominal valve size identify the mass reference. The current listing code is preserved; this mass reference does not certify an unlisted accessory code or broaden catalog fitment. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac Mounting Accessory - F-2L030LB

    Airtac F-2L series: valve mounting bracket - F-2L030LB

    Specifications: F-2L030LB is the existing listing identifier for an LB-type mounting accessory associated with the 030 body-size branch. It is a mounting component, not an electrically operated valve. The supplied manufacturer catalog lists F-2S030LB for the corresponding legacy valve group; it does not list F-2L030LB as an official ordering code. Product Catalogs and Comparison Guide Download Airtac Coil and Accessories Catalog (PDF) Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Ordering-Code Verification Confirm the exact bracket before ordering. The existing listing code is retained, but its correspondence to the catalog bracket requires confirmation. The valve series update does not prove that this legacy bracket is replaced by an A-suffixed version. Parameter Details Existing listing identifier F-2L030LB Catalog legacy bracket code F-2S030LB Legacy chart application 2W / 2KW, 2S / 2KS and 2L / 2KL, corresponding 030 size branch New-generation chart code F-2WA030LB New chart application Corresponding 2LA / 2KLA 030 branch, as shown on the new accessory selection page Current status Listing-code match and supplied component require confirmation; no SKU has been renamed Function and Catalog Scope The LB accessory mounts the valve body using the optional bracket arrangement illustrated in the valve catalog. Bracket-related dimensions in those illustrations refer to the assembled installation and must not be relabelled as a fully dimensioned loose-part drawing. The source selection table lists brackets for the 030, 050, 150, 200 and 250 branches. The 320, 400 and 500 branches are shown without mounting accessories. Packing, Dimensions and Weight Parameter Details Packing components and quantity Not specified in the supplied bracket selection table Standalone bracket dimensions Not provided; confirm the matching bracket drawing Bracket material Not stated in the supplied selection table Bracket weight Not stated; no valve weight is substituted Electrical and fluid specifications Not applicable to this mounting component For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Reference Weight Estimated reference weight: 20 g. The mass reference is the DOLD listing for F-2S030LB, which lists an item weight of 20 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The catalog-shared mounting-bracket family and nominal valve size identify the mass reference. The current listing code is preserved; this mass reference does not certify an unlisted accessory code or broaden catalog fitment. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015CIG

    Airtac 2L series: two-way fluid solenoid valve - 2L15015CIG

    Specifications: 2L15015CIG is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects G1/2; voltage code C selects AC110V; electrical entry is grommet / flying lead with a 0.5 m lead. Thread suffix G selects G threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015CIG will be supplied as 2LA15015CIG (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015CIG in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — G1/2 Voltage code C — AC110V Electrical-entry code I — grommet / flying lead, 0.5 m Thread code G — G Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 665 g = 675 g terminal value − 10 g grommet reduction. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC110V Electrical entry grommet / flying lead with a 0.5 m lead Coil family listed for this valve CLA116 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 10 VA at 50 Hz; 8 VA at 60 Hz Catalog temperature rise 35°C at 50 Hz; 30°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L grommet / flying-lead drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P G1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015CIT

    Airtac 2L series: two-way fluid solenoid valve - 2L15015CIT

    Specifications: 2L15015CIT is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects NPT1/2; voltage code C selects AC110V; electrical entry is grommet / flying lead with a 0.5 m lead. Thread suffix T selects NPT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015CIT will be supplied as 2LA15015CIT (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015CIT in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — NPT1/2 Voltage code C — AC110V Electrical-entry code I — grommet / flying lead, 0.5 m Thread code T — NPT Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 665 g = 675 g terminal value − 10 g grommet reduction. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC110V Electrical entry grommet / flying lead with a 0.5 m lead Coil family listed for this valve CLA116 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 10 VA at 50 Hz; 8 VA at 60 Hz Catalog temperature rise 35°C at 50 Hz; 30°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L grommet / flying-lead drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P NPT1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015CT

    Airtac 2L series: two-way fluid solenoid valve - 2L15015CT

    Specifications: 2L15015CT is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects NPT1/2; voltage code C selects AC110V; electrical entry is terminal connector. Thread suffix T selects NPT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015CT will be supplied as 2LA15015CT (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015CT in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — NPT1/2 Voltage code C — AC110V Electrical-entry code Omitted — terminal Thread code T — NPT Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 675 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC110V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 10 VA at 50 Hz; 8 VA at 60 Hz Catalog temperature rise 35°C at 50 Hz; 30°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 77 mm AB — body span AB 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P NPT1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015E

    Airtac 2L series: two-way fluid solenoid valve - 2L15015E

    Specifications: 2L15015E is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects PT1/2; voltage code E selects AC24V; electrical entry is terminal connector. The omitted thread suffix selects PT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015E will be supplied as 2LA15015E (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015E in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — PT1/2 Voltage code E — AC24V Electrical-entry code Omitted — terminal Thread code Omitted — PT Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 675 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC24V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 10 VA at 50 Hz; 8 VA at 60 Hz Catalog temperature rise 35°C at 50 Hz; 30°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 77 mm AB — body span AB 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P PT1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015EG

    Airtac 2L series: two-way fluid solenoid valve - 2L15015EG

    Specifications: 2L15015EG is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects G1/2; voltage code E selects AC24V; electrical entry is terminal connector. Thread suffix G selects G threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015EG will be supplied as 2LA15015EG (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015EG in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — G1/2 Voltage code E — AC24V Electrical-entry code Omitted — terminal Thread code G — G Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 675 g; terminal version. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC24V Electrical entry terminal connector Coil family listed for this valve CDA116 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 10 VA at 50 Hz; 8 VA at 60 Hz Catalog temperature rise 35°C at 50 Hz; 30°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L terminal drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 77 mm AB — body span AB 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P G1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015EI

    Airtac 2L series: two-way fluid solenoid valve - 2L15015EI

    Specifications: 2L15015EI is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects PT1/2; voltage code E selects AC24V; electrical entry is grommet / flying lead with a 0.5 m lead. The omitted thread suffix selects PT threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015EI will be supplied as 2LA15015EI (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015EI in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — PT1/2 Voltage code E — AC24V Electrical-entry code I — grommet / flying lead, 0.5 m Thread code Omitted — PT Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 665 g = 675 g terminal value − 10 g grommet reduction. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC24V Electrical entry grommet / flying lead with a 0.5 m lead Coil family listed for this valve CLA116 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 10 VA at 50 Hz; 8 VA at 60 Hz Catalog temperature rise 35°C at 50 Hz; 30°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L grommet / flying-lead drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P PT1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.

  • Airtac 2L150: 2 Way Solenoid Valve - 2L15015EIG

    Airtac 2L series: two-way fluid solenoid valve - 2L15015EIG

    Specifications: 2L15015EIG is an AirTAC 2L 2/2-way internally piloted, normally closed solenoid valve. 150 identifies the orifice-size branch; port code 15 selects G1/2; voltage code E selects AC24V; electrical entry is grommet / flying lead with a 0.5 m lead. Thread suffix G selects G threads. Product Catalogs and Comparison Guide Download Airtac 2L Product Catalog (PDF) Download Airtac 2LA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) New shared coil and mounting-accessory selection: 2KLA PDF page 5 (printed page 196) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2L vs 2LA: Dimensions and Replacement Guide Ordering and Delivery Orders for 2L15015EIG will be supplied as 2LA15015EIG (2LA). This is our ordering and delivery policy. It does not mean that the old and new dimensions, mounting details or electrical data are identical. The technical information below describes 2L15015EIG in the 2L catalog. For the supplied replacement, check the new catalog and comparison guide before installation. Operation and Construction This two-port, two-position valve is normally closed in its unenergized state. The valve uses internal pilot operation and requires the stated pressure differential to operate. The catalog specifies a SUS304 stainless-steel body, a PTFE (Teflon) standard seal, Class H coil insulation and IP65 coil protection. The compact construction is intended to make installation and removal convenient. Model Code Explained Code position Meaning for this model Family 2L — 2/2-way internally piloted, normally closed Size code 150 — 15 mm orifice Port-size code 15 — G1/2 Voltage code E — AC24V Electrical-entry code I — grommet / flying lead, 0.5 m Thread code G — G Technical Specifications Parameter Details Actuation and normal state Internally piloted; normally closed Suitable fluids Steam, high-temperature water and oil Orifice diameter 15 mm Flow coefficient Cv 5.50 Effective flow area 100 mm² Operating pressure differential 0.05–1 MPa differential (inlet pressure minus outlet pressure). Proof pressure 1.5 MPa Body material SUS304 stainless steel Standard seal PTFE (Teflon) Viscosity limit Under 20 cSt in the general specification; see the separate low-oil-temperature footnote below. Oil temperature −10 to 150°C; the −10°C entry carries a footnote stating 50 cSt or less. Water temperature 1 to 150°C Steam temperature Maximum 183°C; the minimum is not stated. Ambient temperature −20 to 100°C Catalog reference weight 665 g = 675 g terminal value − 10 g grommet reduction. Operating differential is the pressure difference across the valve, not an independent flow rating. The general viscosity limit and the oil-temperature footnote are both retained from the source; they must be checked together for the intended fluid. Catalog weight is a reference value; the actual product prevails. Electrical Specifications Parameter Details Rated voltage AC24V Electrical entry grommet / flying lead with a 0.5 m lead Coil family listed for this valve CLA116 Supply tolerance ±15% Supply frequency 50 or 60 Hz; consumption differs with frequency. Power consumption 10 VA at 50 Hz; 8 VA at 60 Hz Catalog temperature rise 35°C at 50 Hz; 30°C at 60 Hz Coil insulation Class H Coil protection IP65 External and Mounting Dimensions The following values are from the 2L grommet / flying-lead drawing, PDF page 4 (printed page 213). Each letter refers to its own dimension line. Values are in millimetres except threads; “—” means that the source does not list a value. Drawing reference Current configuration A — drawing length A 70 mm B — drawing width B 46 mm BA — port-side span BA 27.5 mm C — drawing height C 107 mm D — drawing dimension D 80 mm E — drawing dimension E 6.4 mm EA — drawing dimension EA 8 mm EB — drawing dimension EB 65 mm EC — drawing dimension EC 36.5 mm F — drawing dimension F 30.5 mm P — fluid port thread P G1/2 The drawing labels the mounting bracket as optional. D, E, EA, EB, EC and F are separate installation references; do not combine dimension lines into an invented overall measurement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Flow and Performance Charts This configuration has a 15 mm orifice, Cv 5.50 and 100 mm² effective area. The catalog provides a chart labelled “Fluid: Vacuum” showing P2, upstream-pressure curves P1, a minimum-working-pressure boundary, subsonic/sonic regions and a critical-pressure boundary. Its Q axis is labelled L/min (ANR), with separate scales for Ø15, Ø20, Ø25, Ø35, Ø40 and Ø50 mm. The P2 chart reaches 1.0 MPa. The water chart plots Q in L/min against ΔP=P1−P2 in MPa; marked scales run from 0.02 to 0.5 MPa and 30 to 900 L/min. Its large intermediate curve is labelled Ø32, while the 320 ordering/specification table states a Ø35 mm orifice; retain this source distinction when reading the graph. Read the actual curve for the operating condition in the PDF. Axis maxima, plotted endpoints and other bore-size curves are not guaranteed flow ratings for this model; no interpolated flow claim is added here. Internal Structure Reference The catalog cross-section is labelled 2L150 (grommet). The numbered names below identify that reference drawing; they are not a packing list, individual ordering codes, quantities or a claim that every branch has an identical construction. Drawing item Component name 1 Body 2 Fixed ring 3 Airtight gasket 4 O-ring 5 Wear ring 6 Gasket 7 Screw 8 Spring 9 Cover 10 Spring 11 Screw 12 Spring 13 Spring washer 14 Coil assembly 15 Washer 16 E clip 17 Movable core 18 Fixed plate 19 O-ring 20 Fixed cap 21 Airtight ring 22 Plug 23 Spring 24 Piston 25 Spacer 26 O-ring Mounting Accessories and Selection The catalog accessory selection identifies F-2S150LB as the optional LB mounting bracket for this size branch. The valve drawing shows an optional bracket; the catalog does not identify it as included with the valve or list its packing quantity. Order the bracket separately when required, after confirming the mounting arrangement. Match the full voltage, electrical entry, thread and normal-state configuration. A valve series update does not establish that its old coil, connector or mounting bracket fits the new generation. Follow the flow direction shown on the body and check the exact catalog drawing before installation. Series Ordering Options The following are available choices within 2L. The current model uses only the configuration decoded above; H applies to the direct-acting 030/050 branches. Ordering position Permitted catalog choices Direct-acting branches 030: port codes 06 (1/8) or 08 (1/4); 050: 10 (3/8) or 15 (1/2). Pressure code omitted = standard; H = high pressure. Internally piloted branches 150/15 = Ø15 mm, 1/2; 200/20 = Ø20 mm, 3/4; 250/25 = Ø25 mm, 1; 320/32 = Ø35 mm, 1 1/4; 400/40 = Ø40 mm, 1 1/2; 500/50 = Ø50 mm, 2. Voltage codes A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V. Electrical-entry choices Omitted = terminal; I = grommet / flying lead, length 0.5 m. Thread choices Omitted = PT; G = G thread; T = NPT. These are alternatives, not simultaneous features.