500 products

2LA / 2KLA Series Stainless Steel Solenoid Valve

  • Product Features
  • Specifications (Valve)
  • Specifications (Coil)
  • Ordering Codes

Product Features

  • Diverse Functions:
    • 2LA Series: 2/2 Way Normally Closed (NC). Available in Direct Acting and Pilot Operated types.
    • 2KLA Series: 2/2 Way Normally Open (NO). Direct Acting type.
  • Material: Body made of SUS304 Stainless Steel, suitable for corrosive environments.
  • High Performance: Uses H-grade heat-resistant coil and PTFE (Teflon) seals.
  • Wide Application: Ideal for high temperature fluids, hot water, steam, and oil.
  • Protection: Coil protection class IP65.

Valve Mechanical Specifications

1. Direct Acting Type (2LA - NC / 2KLA - NO)

Function Model Port Size Orifice (mm) Cv Area (mm²) Weight (g) Max Op. Diff. Pressure Max Proof Pressure
MPa psi MPa psi
NC
(2LA)
2LAH030 1/8", 1/4" 2.0 0.18 3.0 244.5 2.0 300 3.0 450
2LA030 3.0 0.33 6.0 244.5 1.0 150
2LAH050 3/8", 1/2" 4.0 0.55 10.0 529 2.0 300
2LA050 5.0 0.83 15.0 529 1.0 150
NO
(2KLA)
2KLAH030 1/8", 1/4" 2.0 0.18 3.0 243.5 1.5 220
2KLA030 3.0 0.33 6.0 243.5 0.7 100
2KLAH050 3/8", 1/2" 4.0 0.55 10.0 528 1.5 220
2KLA050 5.0 0.83 15.0 528 0.7 100

2. Pilot Operated Type (2LA Only)

Model Port Size Orifice (mm) Cv Weight (g) Op. Pressure (MPa) Proof Pressure (MPa)
2LA150-15 1/2" 15.0 5.50 570 Max: 0.7
Min: 0.05
1.5
2LA200-20 3/4" 20.0 9.50 723
2LA250-25 1" 25.0 12.50 1027
2LA320-32 1-1/4" 35.0 23.00 2262
2LA400-40 1-1/2" 40.0 31.00 2642
2LA500-50 2" 50.0 49.00 3509
Fluid: Air, Water, Steam, Oil.
Viscosity Limit: Below 20CST (Direct Acting: 50CST).
Fluid Temp: Oil -10~150°C | Hot Water 1~150°C | Steam < 183°C.

Coil & Electrical Specifications

1. Coil Parameters (Power & Temp Rise)

Coil Series Power Type Voltage (V) Freq (Hz) Voltage Tolerance Power (VA/W) Temp Rise (°C)
Start Hold
110 Series
(For 030 Valves)
AC 220, 110, 24 50 ±15% 10.0 VA 15.0 VA 50
60 8.0 VA 11.0 VA 45
24 50/60 (Refer to above) 50/45
DC 24, 12 - ±10% 6.5 W 50
160 Series
(For 050/150+ Valves)
AC 220, 110, 24 50 ±15% 25.0 VA 35.0 VA 65
60 22.0 VA 30.0 VA 60
24 50/60 (Refer to above) 65/60
DC 24, 12 - ±10% 12.0 W 50

2. Coil Selection Guide

Valve Model Coil Series
2LA□030 / 2KLA□030 110 Series (ID Φ10.0mm)
2LA□050 / 2KLA□050
2LA150 ~ 2LA500
160 Series (ID Φ16.0mm)

Ordering Codes

1. Direct Acting Valve (2LA / 2KLA)

Example: 2KLA H 030 08 A G

Code Item Options
2LA / 2KLA Model 2LA: NC (Normally Closed)
2KLA: NO (Normally Open)
H Pressure Type H: High Pressure
Blank: Standard Pressure
030 Orifice 030: Φ3.0/2.0mm
050: Φ5.0/4.0mm
08 Port Size 06: 1/8", 08: 1/4" (For 030)
10: 3/8", 15: 1/2" (For 050)
A Voltage A: AC220V   B: DC24V
C: AC110V   E: AC24V
Blank Connection Blank: DIN Terminal
I: Grommet (Lead Wire)
Blank Thread Blank: PT   G: G   T: NPT

2. Pilot Operated Valve (2LA)

Example: 2LA 150 15 A G

Code Item Options
2LA Model 2LA Pilot Operated NC
150 Orifice 150: Φ15mm ... 500: Φ50mm
15 Port Size 15: 1/2" ... 50: 2"
A Voltage A, B, C, E, F
Blank Connection DIN Terminal / Grommet
Blank Thread PT, G, NPT

3. Coil & Connector Ordering

Item Ordering Example Description
Coil CD A 110 A H CD/CL: DIN/Lead Wire
110/160: Spec (ID 10mm/16mm)
A/B..: Voltage
H: Heat Class (Must specify H for 2LA/2KLA)
Connector F-2WA030LBF Connector with light (Universal AC/DC)
  • Airtac CDA110 series: replacement solenoid coil - CDA110FH Airtac CDA110 series: replacement solenoid coil - CDA110FH

    Airtac CDA110 series: replacement solenoid coil - CDA110FH

    Specifications: CDA110FH is an AirTAC 110-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A110 identifies a 10.0 mm coil bore; F selects DC12V; H selects Class H. The omitted valve-type code selects a normally-closed valve application. This exact order is listed for 2LA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CDA110FH: 2LA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, terminal / DIN entry, DC12V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2LA — normally closed (NC) 2LA030, 2LA150, 2LA200, 2LA250 model groups. The valve-type position in this coil ordering code is blank, selecting normally-closed (NC) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2LA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CDA110FH for the listed valve groups when DC12V, terminal / DIN entry, a 10.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses a terminal connection. The new shared coil page does not assign a PL2925 or PL3030 connector code to the 110/160 family; connector compatibility must not be copied from the older 116/170 coils. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CDA110FH Coil-bore code A110 — 10.0 mm bore Electrical entry CD — terminal / DIN Voltage F — DC12V Valve-type position normally closed (omitted valve-type code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order H Application selected by code Normally closed Power consumption — general Class F reference 6.5 W Temperature rise — general Class F reference 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 100 g. The mass reference is the DOLD listing for CDA110FH, which lists an item weight of 100 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The selected complete SKU matches the supplier record. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA110KAH

    Airtac CLA110 series: replacement solenoid coil - CLA110KAH

    Specifications: CLA110KAH is an AirTAC 110-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A110 identifies a 10.0 mm coil bore; A selects AC220V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA110KAH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, grommet / flying-lead entry, AC220V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA030, 2KLA150, 2KLA200, 2KLA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA110KAH for the listed valve groups when AC220V, grommet / flying-lead entry, a 10.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA110KAH Coil-bore code A110 — 10.0 mm bore Electrical entry CL — grommet / flying lead Voltage A — AC220V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 15 VA at 50 Hz; 11 VA at 60 Hz Temperature rise — general Class F reference 50°C at 50 Hz; 45°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 110 g. The mass reference is the DOLD listing for CLA110AH, which lists an item weight of 110 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA160KBH

    Airtac CLA160 series: replacement solenoid coil - CLA160KBH

    Specifications: CLA160KBH is an AirTAC 160-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A160 identifies a 16.0 mm coil bore; B selects DC24V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA160KBH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, grommet / flying-lead entry, DC24V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA050, 2KLA320, 2KLA400, 2KLA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA160KBH for the listed valve groups when DC24V, grommet / flying-lead entry, a 16.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA160KBH Coil-bore code A160 — 16.0 mm bore Electrical entry CL — grommet / flying lead Voltage B — DC24V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 12 W Temperature rise — general Class F reference 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 260 g. The mass reference is the DOLD listing for CLA160BH, which lists an item weight of 260 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA160KCH

    Airtac CLA160 series: replacement solenoid coil - CLA160KCH

    Specifications: CLA160KCH is an AirTAC 160-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A160 identifies a 16.0 mm coil bore; C selects AC110V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA160KCH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, grommet / flying-lead entry, AC110V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA050, 2KLA320, 2KLA400, 2KLA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA160KCH for the listed valve groups when AC110V, grommet / flying-lead entry, a 16.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA160KCH Coil-bore code A160 — 16.0 mm bore Electrical entry CL — grommet / flying lead Voltage C — AC110V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 35 VA at 50 Hz; 30 VA at 60 Hz Temperature rise — general Class F reference 65°C at 50 Hz; 60°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 260 g. The mass reference is the DOLD listing for CLA160CH, which lists an item weight of 260 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA110KFH

    Airtac CLA110 series: replacement solenoid coil - CLA110KFH

    Specifications: CLA110KFH is an AirTAC 110-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A110 identifies a 10.0 mm coil bore; F selects DC12V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA110KFH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, grommet / flying-lead entry, DC12V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA030, 2KLA150, 2KLA200, 2KLA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA110KFH for the listed valve groups when DC12V, grommet / flying-lead entry, a 10.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA110KFH Coil-bore code A110 — 10.0 mm bore Electrical entry CL — grommet / flying lead Voltage F — DC12V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 6.5 W Temperature rise — general Class F reference 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 110 g. The mass reference is the DOLD listing for CLA110FH, which lists an item weight of 110 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA160KA

    Airtac CLA160 series: replacement solenoid coil - CLA160KA

    Specifications: CLA160KA is an AirTAC 160-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A160 identifies a 16.0 mm coil bore; A selects AC220V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA160KA: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, grommet / flying-lead entry, AC220V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA050 model groups. 2KSA — normally open (NO) 2KSA050, 2KSA320, 2KSA400, 2KSA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA160KA for the listed valve groups when AC220V, grommet / flying-lead entry, a 16.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA160KA Coil-bore code A160 — 16.0 mm bore Electrical entry CL — grommet / flying lead Voltage A — AC220V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order F Application selected by code Normally open Power consumption 35 VA at 50 Hz; 30 VA at 60 Hz Catalog temperature rise 65°C at 50 Hz; 60°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 260 g. The mass reference is the DOLD listing for CLA160A, which lists an item weight of 260 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA110KEH

    Airtac CLA110 series: replacement solenoid coil - CLA110KEH

    Specifications: CLA110KEH is an AirTAC 110-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A110 identifies a 10.0 mm coil bore; E selects AC24V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA110KEH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, grommet / flying-lead entry, AC24V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA030, 2KLA150, 2KLA200, 2KLA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA110KEH for the listed valve groups when AC24V, grommet / flying-lead entry, a 10.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA110KEH Coil-bore code A110 — 10.0 mm bore Electrical entry CL — grommet / flying lead Voltage E — AC24V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 15 VA at 50 Hz; 11 VA at 60 Hz Temperature rise — general Class F reference 50°C at 50 Hz; 45°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 110 g. The mass reference is the DOLD listing for CLA110EH, which lists an item weight of 110 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA160KF

    Airtac CLA160 series: replacement solenoid coil - CLA160KF

    Specifications: CLA160KF is an AirTAC 160-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A160 identifies a 16.0 mm coil bore; F selects DC12V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA160KF: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, grommet / flying-lead entry, DC12V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA050 model groups. 2KSA — normally open (NO) 2KSA050, 2KSA320, 2KSA400, 2KSA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA160KF for the listed valve groups when DC12V, grommet / flying-lead entry, a 16.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA160KF Coil-bore code A160 — 16.0 mm bore Electrical entry CL — grommet / flying lead Voltage F — DC12V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order F Application selected by code Normally open Power consumption 12 W Catalog temperature rise 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 260 g. The mass reference is the DOLD listing for CLA160F, which lists an item weight of 260 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA160KFH

    Airtac CLA160 series: replacement solenoid coil - CLA160KFH

    Specifications: CLA160KFH is an AirTAC 160-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A160 identifies a 16.0 mm coil bore; F selects DC12V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA160KFH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, grommet / flying-lead entry, DC12V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA050, 2KLA320, 2KLA400, 2KLA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA160KFH for the listed valve groups when DC12V, grommet / flying-lead entry, a 16.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA160KFH Coil-bore code A160 — 16.0 mm bore Electrical entry CL — grommet / flying lead Voltage F — DC12V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 12 W Temperature rise — general Class F reference 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 260 g. The mass reference is the DOLD listing for CLA160FH, which lists an item weight of 260 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA110KC

    Airtac CLA110 series: replacement solenoid coil - CLA110KC

    Specifications: CLA110KC is an AirTAC 110-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A110 identifies a 10.0 mm coil bore; C selects AC110V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA110KC: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, grommet / flying-lead entry, AC110V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA030, 2KWA150, 2KWA200, 2KWA250 model groups. 2KSA — normally open (NO) 2KSA030, 2KSA150, 2KSA200, 2KSA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA110KC for the listed valve groups when AC110V, grommet / flying-lead entry, a 10.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA110KC Coil-bore code A110 — 10.0 mm bore Electrical entry CL — grommet / flying lead Voltage C — AC110V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order F Application selected by code Normally open Power consumption 15 VA at 50 Hz; 11 VA at 60 Hz Catalog temperature rise 50°C at 50 Hz; 45°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 110 g. The mass reference is the DOLD listing for CLA110C, which lists an item weight of 110 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA160KB

    Airtac CLA160 series: replacement solenoid coil - CLA160KB

    Specifications: CLA160KB is an AirTAC 160-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A160 identifies a 16.0 mm coil bore; B selects DC24V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA160KB: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, grommet / flying-lead entry, DC24V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA050 model groups. 2KSA — normally open (NO) 2KSA050, 2KSA320, 2KSA400, 2KSA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA160KB for the listed valve groups when DC24V, grommet / flying-lead entry, a 16.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA160KB Coil-bore code A160 — 16.0 mm bore Electrical entry CL — grommet / flying lead Voltage B — DC24V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order F Application selected by code Normally open Power consumption 12 W Catalog temperature rise 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 260 g. The mass reference is the DOLD listing for CLA160B, which lists an item weight of 260 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CDA110KCH

    Airtac CDA110 series: replacement solenoid coil - CDA110KCH

    Specifications: CDA110KCH is an AirTAC 110-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A110 identifies a 10.0 mm coil bore; C selects AC110V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CDA110KCH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, terminal / DIN entry, AC110V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA030, 2KLA150, 2KLA200, 2KLA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CDA110KCH for the listed valve groups when AC110V, terminal / DIN entry, a 10.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses a terminal connection. The new shared coil page does not assign a PL2925 or PL3030 connector code to the 110/160 family; connector compatibility must not be copied from the older 116/170 coils. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CDA110KCH Coil-bore code A110 — 10.0 mm bore Electrical entry CD — terminal / DIN Voltage C — AC110V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 15 VA at 50 Hz; 11 VA at 60 Hz Temperature rise — general Class F reference 50°C at 50 Hz; 45°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 100 g. The mass reference is the DOLD listing for CDA110CH, which lists an item weight of 100 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA110KA

    Airtac CLA110 series: replacement solenoid coil - CLA110KA

    Specifications: CLA110KA is an AirTAC 110-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A110 identifies a 10.0 mm coil bore; A selects AC220V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA110KA: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, grommet / flying-lead entry, AC220V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA030, 2KWA150, 2KWA200, 2KWA250 model groups. 2KSA — normally open (NO) 2KSA030, 2KSA150, 2KSA200, 2KSA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA110KA for the listed valve groups when AC220V, grommet / flying-lead entry, a 10.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA110KA Coil-bore code A110 — 10.0 mm bore Electrical entry CL — grommet / flying lead Voltage A — AC220V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order F Application selected by code Normally open Power consumption 15 VA at 50 Hz; 11 VA at 60 Hz Catalog temperature rise 50°C at 50 Hz; 45°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 110 g. The mass reference is the DOLD listing for CLA110A, which lists an item weight of 110 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA160KAH

    Airtac CLA160 series: replacement solenoid coil - CLA160KAH

    Specifications: CLA160KAH is an AirTAC 160-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A160 identifies a 16.0 mm coil bore; A selects AC220V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA160KAH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, grommet / flying-lead entry, AC220V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA050, 2KLA320, 2KLA400, 2KLA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA160KAH for the listed valve groups when AC220V, grommet / flying-lead entry, a 16.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA160KAH Coil-bore code A160 — 16.0 mm bore Electrical entry CL — grommet / flying lead Voltage A — AC220V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 35 VA at 50 Hz; 30 VA at 60 Hz Temperature rise — general Class F reference 65°C at 50 Hz; 60°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 260 g. The mass reference is the DOLD listing for CLA160AH, which lists an item weight of 260 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CDA110KFH

    Airtac CDA110 series: replacement solenoid coil - CDA110KFH

    Specifications: CDA110KFH is an AirTAC 110-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A110 identifies a 10.0 mm coil bore; F selects DC12V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CDA110KFH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, terminal / DIN entry, DC12V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA030, 2KLA150, 2KLA200, 2KLA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CDA110KFH for the listed valve groups when DC12V, terminal / DIN entry, a 10.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses a terminal connection. The new shared coil page does not assign a PL2925 or PL3030 connector code to the 110/160 family; connector compatibility must not be copied from the older 116/170 coils. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CDA110KFH Coil-bore code A110 — 10.0 mm bore Electrical entry CD — terminal / DIN Voltage F — DC12V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 6.5 W Temperature rise — general Class F reference 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 100 g. The mass reference is the DOLD listing for CDA110FH, which lists an item weight of 100 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CDA160KE

    Airtac CDA160 series: replacement solenoid coil - CDA160KE

    Specifications: CDA160KE is an AirTAC 160-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A160 identifies a 16.0 mm coil bore; E selects AC24V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CDA160KE: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, terminal / DIN entry, AC24V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA050 model groups. 2KSA — normally open (NO) 2KSA050, 2KSA320, 2KSA400, 2KSA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CDA160KE for the listed valve groups when AC24V, terminal / DIN entry, a 16.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses a terminal connection. The new shared coil page does not assign a PL2925 or PL3030 connector code to the 110/160 family; connector compatibility must not be copied from the older 116/170 coils. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CDA160KE Coil-bore code A160 — 16.0 mm bore Electrical entry CD — terminal / DIN Voltage E — AC24V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order F Application selected by code Normally open Power consumption 35 VA at 50 Hz; 30 VA at 60 Hz Catalog temperature rise 65°C at 50 Hz; 60°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 250 g. The mass reference is the DOLD listing for CDA160E, which lists an item weight of 250 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA110KB

    Airtac CLA110 series: replacement solenoid coil - CLA110KB

    Specifications: CLA110KB is an AirTAC 110-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A110 identifies a 10.0 mm coil bore; B selects DC24V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA110KB: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, grommet / flying-lead entry, DC24V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA030, 2KWA150, 2KWA200, 2KWA250 model groups. 2KSA — normally open (NO) 2KSA030, 2KSA150, 2KSA200, 2KSA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA110KB for the listed valve groups when DC24V, grommet / flying-lead entry, a 10.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA110KB Coil-bore code A110 — 10.0 mm bore Electrical entry CL — grommet / flying lead Voltage B — DC24V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order F Application selected by code Normally open Power consumption 6.5 W Catalog temperature rise 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 110 g. The mass reference is the DOLD listing for CLA110B, which lists an item weight of 110 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA160KE

    Airtac CLA160 series: replacement solenoid coil - CLA160KE

    Specifications: CLA160KE is an AirTAC 160-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A160 identifies a 16.0 mm coil bore; E selects AC24V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA160KE: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, grommet / flying-lead entry, AC24V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA050 model groups. 2KSA — normally open (NO) 2KSA050, 2KSA320, 2KSA400, 2KSA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA160KE for the listed valve groups when AC24V, grommet / flying-lead entry, a 16.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA160KE Coil-bore code A160 — 16.0 mm bore Electrical entry CL — grommet / flying lead Voltage E — AC24V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order F Application selected by code Normally open Power consumption 35 VA at 50 Hz; 30 VA at 60 Hz Catalog temperature rise 65°C at 50 Hz; 60°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 260 g. The mass reference is the DOLD listing for CLA160E, which lists an item weight of 260 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CDA160KC

    Airtac CDA160 series: replacement solenoid coil - CDA160KC

    Specifications: CDA160KC is an AirTAC 160-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A160 identifies a 16.0 mm coil bore; C selects AC110V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CDA160KC: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, terminal / DIN entry, AC110V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA050 model groups. 2KSA — normally open (NO) 2KSA050, 2KSA320, 2KSA400, 2KSA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CDA160KC for the listed valve groups when AC110V, terminal / DIN entry, a 16.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses a terminal connection. The new shared coil page does not assign a PL2925 or PL3030 connector code to the 110/160 family; connector compatibility must not be copied from the older 116/170 coils. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CDA160KC Coil-bore code A160 — 16.0 mm bore Electrical entry CD — terminal / DIN Voltage C — AC110V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order F Application selected by code Normally open Power consumption 35 VA at 50 Hz; 30 VA at 60 Hz Catalog temperature rise 65°C at 50 Hz; 60°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 250 g. The mass reference is the DOLD listing for CDA160C, which lists an item weight of 250 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CDA160KFH

    Airtac CDA160 series: replacement solenoid coil - CDA160KFH

    Specifications: CDA160KFH is an AirTAC 160-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A160 identifies a 16.0 mm coil bore; F selects DC12V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CDA160KFH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, terminal / DIN entry, DC12V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA050, 2KLA320, 2KLA400, 2KLA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CDA160KFH for the listed valve groups when DC12V, terminal / DIN entry, a 16.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses a terminal connection. The new shared coil page does not assign a PL2925 or PL3030 connector code to the 110/160 family; connector compatibility must not be copied from the older 116/170 coils. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CDA160KFH Coil-bore code A160 — 16.0 mm bore Electrical entry CD — terminal / DIN Voltage F — DC12V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 12 W Temperature rise — general Class F reference 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 250 g. The mass reference is the DOLD listing for CDA160FH, which lists an item weight of 250 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CDA110KE

    Airtac CDA110 series: replacement solenoid coil - CDA110KE

    Specifications: CDA110KE is an AirTAC 110-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A110 identifies a 10.0 mm coil bore; E selects AC24V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CDA110KE: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, terminal / DIN entry, AC24V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA030, 2KWA150, 2KWA200, 2KWA250 model groups. 2KSA — normally open (NO) 2KSA030, 2KSA150, 2KSA200, 2KSA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CDA110KE for the listed valve groups when AC24V, terminal / DIN entry, a 10.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses a terminal connection. The new shared coil page does not assign a PL2925 or PL3030 connector code to the 110/160 family; connector compatibility must not be copied from the older 116/170 coils. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CDA110KE Coil-bore code A110 — 10.0 mm bore Electrical entry CD — terminal / DIN Voltage E — AC24V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order F Application selected by code Normally open Power consumption 15 VA at 50 Hz; 11 VA at 60 Hz Catalog temperature rise 50°C at 50 Hz; 45°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 100 g. The mass reference is the DOLD listing for CDA110E, which lists an item weight of 100 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CDA110KBH

    Airtac CDA110 series: replacement solenoid coil - CDA110KBH

    Specifications: CDA110KBH is an AirTAC 110-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A110 identifies a 10.0 mm coil bore; B selects DC24V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CDA110KBH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, terminal / DIN entry, DC24V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA030, 2KLA150, 2KLA200, 2KLA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CDA110KBH for the listed valve groups when DC24V, terminal / DIN entry, a 10.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses a terminal connection. The new shared coil page does not assign a PL2925 or PL3030 connector code to the 110/160 family; connector compatibility must not be copied from the older 116/170 coils. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CDA110KBH Coil-bore code A110 — 10.0 mm bore Electrical entry CD — terminal / DIN Voltage B — DC24V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 6.5 W Temperature rise — general Class F reference 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 100 g. The mass reference is the DOLD listing for CDA110BH, which lists an item weight of 100 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CDA160KAH

    Airtac CDA160 series: replacement solenoid coil - CDA160KAH

    Specifications: CDA160KAH is an AirTAC 160-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A160 identifies a 16.0 mm coil bore; A selects AC220V; H selects Class H. K selects a normally-open valve application. This exact order is listed for 2KLA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CDA160KAH: 2KLA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 16.0 mm bore, terminal / DIN entry, AC220V supply and Class H insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KLA — normally open (NO) 2KLA050, 2KLA320, 2KLA400, 2KLA500 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The final H selects Class H, which the shared selection chart assigns to 2KLA. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 050 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CDA160KAH for the listed valve groups when AC220V, terminal / DIN entry, a 16.0 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses a terminal connection. The new shared coil page does not assign a PL2925 or PL3030 connector code to the 110/160 family; connector compatibility must not be copied from the older 116/170 coils. A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CDA160KAH Coil-bore code A160 — 16.0 mm bore Electrical entry CD — terminal / DIN Voltage A — AC220V Valve-type position normally open (K code) Insulation suffix H — Class H Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Class H data scope: the ordering and selection charts identify this H-class coil for the valve series listed above. The shared numerical electrical matrix is labeled Class F and does not separately certify power consumption or temperature rise for this H-class order. The numerical entries below are that general catalog reference; confirm the exact H-coil nameplate and the relevant valve-specific data. Parameter Details Voltage tolerance ±15% Frequency 50 or 60 Hz Insulation class for this order H Application selected by code Normally open Power consumption — general Class F reference 35 VA at 50 Hz; 30 VA at 60 Hz Temperature rise — general Class F reference 65°C at 50 Hz; 60°C at 60 Hz These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities. Dimensions and Weight Parameter Details Bore diameter 16.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 250 g. The mass reference is the DOLD listing for CDA160AH, which lists an item weight of 250 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

  • Airtac  Fluid Control Valves-Coils & Accessories  - CLA110KF

    Airtac CLA110 series: replacement solenoid coil - CLA110KF

    Specifications: CLA110KF is an AirTAC 110-series solenoid coil, not a complete valve. CL specifies grommet / flying-lead connection; A110 identifies a 10.0 mm coil bore; F selects DC12V; the omitted heat-class suffix selects Class F. K selects a normally-open valve application. This exact order is listed for 2KWA, 2KSA; applicable size groups and connection conditions are listed below. Product Catalogs and Comparison Guide Download Airtac 2KL Product Catalog (PDF) Download Airtac 2KLA Product Catalog (PDF) Legacy coil and mounting-accessory selection: catalog page 205 (PDF) Download Original Product Reference (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement. Applicable Valve Series and Ordering Check Applicable valve series for CLA110KF: 2KWA, 2KSA. Only the model groups in the table below are listed for this exact coil selection. The coil has a 10.0 mm bore, grommet / flying-lead entry, DC12V supply and Class F insulation. Match all four conditions to the valve and existing coil. Valve series and normal state Applicable valve model groups 2KWA — normally open (NO) 2KWA030, 2KWA150, 2KWA200, 2KWA250 model groups. 2KSA — normally open (NO) 2KSA030, 2KSA150, 2KSA200, 2KSA250 model groups. The K in this coil ordering code selects normally-open (NO) service. The table above has already been restricted to that normal state and this order's insulation class. Do not treat the combined NC/NO columns in the general selection chart as an interchangeable coil list. The omitted final insulation suffix selects Class F. The reference is the shared "Coil and accessories" page in the supplied 2KLA catalog, PDF page 5, printed page 196; that page explicitly covers multiple valve series. These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range. Ordering check: order CLA110KF for the listed valve groups when DC12V, grommet / flying-lead entry, a 10.0 mm bore and Class F are required. Confirm the complete valve code, installed coil marking and normal state before replacement. This order uses flying leads (grommet entry). The PL2925/PL3030 terminal-connector assignments are not the wiring arrangement for this CLA coil. A Class F coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution. Component Identity and Ordering Parameter Details Product type Separately ordered solenoid coil Current ordering code CLA110KF Coil-bore code A110 — 10.0 mm bore Electrical entry CL — grommet / flying lead Voltage F — DC12V Valve-type position normally open (K code) Insulation suffix Omitted — Class F Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class. Coil Electrical Data Parameter Details Voltage tolerance ±10% Frequency DC; not applicable Insulation class for this order F Application selected by code Normally open Power consumption 6.5 W Catalog temperature rise 50°C These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed. The general coil specification table is headed Class F, while its ordering and selection tables also offer Class H. It does not provide a separate complete power/temperature-rise matrix for H variants. The 2KLA valve-specific pages additionally differ from the general normally-open power table. Confirm the nameplate of the exact coil before substituting it into a valve. Connection and Components The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram. This is the grommet / flying-lead entry. The independent coil page does not separately specify its loose-coil lead length; do not automatically transfer a complete-valve cable specification. Dimensions and Weight Parameter Details Bore diameter 10.0 mm Separate coil envelope dimensions Not listed in this supplied coil page Separate coil weight Not listed; no complete-valve mass is substituted For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Coil Ordering Options Parameter Details Connection CD = terminal; CL = grommet Bore family A110 = Ø10.0 mm; A160 = Ø16.0 mm Valve-type code Omitted = normally closed; K = normally open Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V Heat-class code Omitted = Class F; H = Class H Reference Weight Estimated reference weight: 110 g. The mass reference is the DOLD listing for CLA110F, which lists an item weight of 110 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The listed normally closed coil with the same size, entry, voltage and insulation selection is used for this K normally open variant; any K-specific construction mass difference is not corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.


You have seen 24 out of 500 products

Footer image

© 2026 Airtac, Powered by Shopify

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • Amazon
  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • USDC
  • Visa