306 products

AIRTAC 3V1 Series Solenoid Valve

AIRTAC 3V1 Series Solenoid Valve

  • Product Features
  • Specifications
  • Electrical Specifications
  • Product Ordering Code

Product Features

  • Direct acting normally closed type, with sensitive commutation.
  • No need for lubrication.
  • Can be used with multiple integrated valves (manifold), saving installation space.
  • Equipped with a manual override, convenient for installation and debugging.
  • Multiple standard voltage levels are available for selection.

Specifications

Item 3V1-M5 3V1-06
Working Medium Air (filtered through 40µm filter or finer)
Operation Type Direct Acting
Port Size [Note 1] M5 PT1/8
Positions Three-way Two-position
Lubrication No need
Operating Pressure Range 0~0.8MPa (0~114psi)
Proof Pressure 1.2MPa (175psi)
Working Temperature -20~70°C
Effective Orifice Φ1.2mm
Body Material Aluminum Alloy
[Note 1] G thread and NPT thread are optional for port thread type.

Electrical Specifications

Item AC220V AC110V AC24V DC24V DC12V
Standard Voltage AC220V AC110V AC24V DC24V DC12V
Operating Voltage Range AC: ±15% DC: ±10%
Power Consumption 4.5VA 4.5VA 5.0VA 3.0W 2.5W
Protection Degree IP65 (DIN40050)
Insulation Class B Class
Wiring Form DIN Socket Type, Lead Wire Type
Excitation Time Below 0.05 seconds
Maximum Operating Frequency [Note 1] 10 times/second
[Note 1] The maximum operating frequency is for the air condition.

Product Ordering Code

Example Code: 3V 1 06 A    3F   

1. Model Code 2. Series Code 3. Port Size 4. Standard Voltage 5. Wiring Form 6. Connection Quantity 7. Thread Type Code
3V: Three-way Two-position Solenoid Valve 1: 1 Series M5: M5 A: AC220V Blank: DIN Socket Type 1F: 1 Connection No Code (for M5 port)
06: 1/8" B: DC24V I: Lead Wire Type [Note] 2F: 2 Connections Blank: PT Thread
C: AC110V 3F: 3 Connections G: G Thread
E: AC24V ... T: NPT Thread
F: DC12V 20F: 20 Connections
Note: The standard wire length for the lead-wire type is 0.5m.
  • Airtac P-200: Air Valve Manifold Blank Plate - P-200M-R2 Airtac P-200: Air Valve Manifold Blank Plate - P-200M-R2 - 2

    Airtac P-200M series: manifold blanking plate kit - P-200M-R2

    Specifications Specifications: P-200M-R2 is the AirTAC blank-plate kit for the 200M manifold size. It closes an unused valve mounting station on that manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model P Accessory kit 200M 200 series manifold R2 Blank plate for manifold Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Blank-plate accessory kit Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C Construction and Kit Contents Blank-plate kits list a blank plate and screws. The catalog lists a blank plate and screws for this accessory kit, but does not specify the screw quantity or provide a separate dimension table for the loose plate. R2 identifies the blank-plate accessory type, not a quantity of two. The blank-plate kit has a separate ordering code from the manifold. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 44 + 23 x (station count − 1) mm KA 34 + 23 x (station count − 1) mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 44 + 23 x (station count − 1) mm KA 34 + 23 x (station count − 1) mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. A and KA depend on the chosen 200M manifold station count, from 1 to 16. The formulas shown are the progression of the published station table, not dimensions assigned to the loose blank plate. The reviewed catalog does not give a separate dimension table for the blank plate itself. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 20 g. The mass reference is the DOLD listing for P-200M-R2, which lists an item weight of 20 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The mass reference is for the independently listed accessory, not for its valve or manifold. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions The base options below match this 200M blanking plate; their thread codes describe common supply/exhaust ports, not a thread on the plate. Order the base and valves separately. Base kits contain the manifold, sealing gasket and screws; component quantities are not specified. Use the matching size-family drawing and sealing surfaces. Item Complete codes and use Matching 200M base, PT 200M with PT 1/4 common supply/exhaust ports; select 1–16 stations within this same size family.200M1F,200M2F,200M3F,200M4F,200M5F,200M6F,200M7F,200M8F,200M9F,200M10F,200M11F,200M12F,200M13F,200M14F,200M15F,200M16F Matching 200M base, G 200M with G 1/4 common supply/exhaust ports; select 1–16 stations within this same size family.200M1FG,200M2FG,200M3FG,200M4FG,200M5FG,200M6FG,200M7FG,200M8FG,200M9FG,200M10FG,200M11FG,200M12FG,200M13FG,200M14FG,200M15FG,200M16FG Matching 200M base, NPT 200M with NPT 1/4 common supply/exhaust ports; select 1–16 stations within this same size family.200M1FT,200M2FT,200M3FT,200M4FT,200M5FT,200M6FT,200M7FT,200M8FT,200M9FT,200M10FT,200M11FT,200M12FT,200M13FT,200M14FT,200M15FT,200M16FT

  • P-300M-R2 Airtac P-300: Air Valve Manifold Blank Plate - P-300M-R2

    Airtac P-300M series: manifold blanking plate kit - P-300M-R2

    Specifications Specifications: P-300M-R2 is the AirTAC blank-plate kit for the 300M manifold size. It closes an unused valve mounting station on that manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model P Accessory kit 300M 300 series manifold R2 Blank plate for manifold Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V300 series 300M; explicit application table in 2022 printed page 82 5V300 series 300M; explicit application table in 2022 printed page 82 4A300 series 300M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Blank-plate accessory kit Matching manifold 300M Published station range 1–12 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C Construction and Kit Contents Blank-plate kits list a blank plate and screws. The catalog lists a blank plate and screws for this accessory kit, but does not specify the screw quantity or provide a separate dimension table for the loose plate. R2 identifies the blank-plate accessory type, not a quantity of two. The blank-plate kit has a separate ordering code from the manifold. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A300 Parameter Details A 52 + 28 x (station count − 1) mm KA 42 + 28 x (station count − 1) mm B 130 mm BA 111 mm BC 95.5 mm BD 40 mm C 68 mm CA 28 mm CB 40 mm D 75 mm E 64 mm F 28 mm G 26 mm H 54 mm K 4.5 mm KB 5 mm KC 26 mm P 3/8 in PA 13.5 mm PB 53 mm Assembly Drawing Reference — 4V300 Parameter Details A 52 + 28 x (station count − 1) mm KA 42 + 28 x (station count − 1) mm B 208 mm BA 190 mm BC 135 mm BD 40 mm C 97 mm CA 28 mm CB 40 mm D 75 mm E 64 mm F 28 mm G 26 mm H 54 mm K 4.5 mm KB 5 mm KC 26 mm P 3/8 in PA 13.5 mm PB 53 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. A and KA depend on the chosen 300M manifold station count, from 1 to 12. The formulas shown are the progression of the published station table, not dimensions assigned to the loose blank plate. The reviewed catalog does not give a separate dimension table for the blank plate itself. Ordering Notes The matching blank-plate kit is P-300M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 30 g. The mass reference is the DOLD listing for P-300M-R2, which lists an item weight of 30 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The mass reference is for the independently listed accessory, not for its valve or manifold. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions The base options below match this 300M blanking plate; their thread codes describe common supply/exhaust ports, not a thread on the plate. Order the base and valves separately. Base kits contain the manifold, sealing gasket and screws; component quantities are not specified. Use the matching size-family drawing and sealing surfaces. Item Complete codes and use Matching 300M base, PT 300M with PT 3/8 common supply/exhaust ports; select 1–12 stations within this same size family.300M1F,300M2F,300M3F,300M4F,300M5F,300M6F,300M7F,300M8F,300M9F,300M10F,300M11F,300M12F Matching 300M base, G 300M with G 3/8 common supply/exhaust ports; select 1–12 stations within this same size family.300M1FG,300M2FG,300M3FG,300M4FG,300M5FG,300M6FG,300M7FG,300M8FG,300M9FG,300M10FG,300M11FG,300M12FG Matching 300M base, NPT 300M with NPT 3/8 common supply/exhaust ports; select 1–12 stations within this same size family.300M1FT,300M2FT,300M3FT,300M4FT,300M5FT,300M6FT,300M7FT,300M8FT,300M9FT,300M10FT,300M11FT,300M12FT

  • Airtac 200M series: pneumatic valve manifold base - 200M3F Airtac 200M series: pneumatic valve manifold base - 200M3F

    Airtac 200M series: pneumatic valve manifold base - 200M3F

    Specifications Specifications: 200M3F is an AirTAC 200M manifold with 3 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 3F 3 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 3 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 90 mm KA 80 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 90 mm KA 80 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 3F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 349.92 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 200M4FG

    Airtac 200M series: pneumatic valve manifold base - 200M4FG

    Specifications Specifications: 200M4FG is an AirTAC 200M manifold with 4 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 4F 4 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 4 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 113 mm KA 103 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 113 mm KA 103 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 4F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 439.34 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • Airtac 3V200M: Air Valve Manifold - 3V200M6F Airtac 3V200M: Air Valve Manifold - 3V200M6F - 2

    Airtac 3V200M series: pneumatic valve manifold base - 3V200M6F

    Specifications Specifications: 3V200M6F is an AirTAC 3V200M manifold with 6 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 3V200M 200 series manifold 6F 6 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 3V200 series 3V200M; explicit application table in the linked PDF and 2022 printed page 81 3A200 series 3V200M; explicit application table in 2022 printed page 122 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 3V200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 6 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 3V200 Parameter Details A 161 mm KA 149 mm B 162.5 mm BA 109 mm BC 27.7 mm C 92.5 mm CA 26 mm CB 35 mm D 45 mm E 40 mm F 23 mm G 23 mm H 35 mm K 4.5 mm KB 6 mm P 1/4 in PA 11.5 mm PB 25 mm Assembly Drawing Reference — 3A200 Parameter Details A 161 mm KA 149 mm B 84 mm BA 69.7 mm BC 27.7 mm C 61 mm CA 26 mm CB 35 mm D 45 mm E 40 mm F 23 mm G 23 mm H 35 mm K 4.5 mm KB 6 mm P 1/4 in PA 11.5 mm PB 25 mm The A and KA values shown are the printed 6F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-3V200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 508.6 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-3V200M-R2 closes an unused valve mounting station on 3V200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • P-100M-R2

    Airtac P-100M series: manifold blanking plate kit - P-100M-R2

    Specifications Specifications: P-100M-R2 is the AirTAC blank-plate kit for the 100M manifold size. It closes an unused valve mounting station on that manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model P Accessory kit 100M 100 series manifold R2 Blank plate for manifold Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Blank-plate accessory kit Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C Construction and Kit Contents Blank-plate kits list a blank plate and screws. The catalog lists a blank plate and screws for this accessory kit, but does not specify the screw quantity or provide a separate dimension table for the loose plate. R2 identifies the blank-plate accessory type, not a quantity of two. The blank-plate kit has a separate ordering code from the manifold. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 38 + 19 x (station count − 1) mm KA 28 + 19 x (station count − 1) mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 38 + 19 x (station count − 1) mm KA 28 + 19 x (station count − 1) mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. A and KA depend on the chosen 100M manifold station count, from 1 to 16. The formulas shown are the progression of the published station table, not dimensions assigned to the loose blank plate. The reviewed catalog does not give a separate dimension table for the blank plate itself. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 10 g. The mass reference is the DOLD listing for P-100M-R2, which lists an item weight of 10 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The mass reference is for the independently listed accessory, not for its valve or manifold. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions The base options below match this 100M blanking plate; their thread codes describe common supply/exhaust ports, not a thread on the plate. Order the base and valves separately. Base kits contain the manifold, sealing gasket and screws; component quantities are not specified. Use the matching size-family drawing and sealing surfaces. Item Complete codes and use Matching 100M base, PT 100M with PT 1/4 common supply/exhaust ports; select 1–16 stations within this same size family.100M1F,100M2F,100M3F,100M4F,100M5F,100M6F,100M7F,100M8F,100M9F,100M10F,100M11F,100M12F,100M13F,100M14F,100M15F,100M16F Matching 100M base, G 100M with G 1/4 common supply/exhaust ports; select 1–16 stations within this same size family.100M1FG,100M2FG,100M3FG,100M4FG,100M5FG,100M6FG,100M7FG,100M8FG,100M9FG,100M10FG,100M11FG,100M12FG,100M13FG,100M14FG,100M15FG,100M16FG Matching 100M base, NPT 100M with NPT 1/4 common supply/exhaust ports; select 1–16 stations within this same size family.100M1FT,100M2FT,100M3FT,100M4FT,100M5FT,100M6FT,100M7FT,100M8FT,100M9FT,100M10FT,100M11FT,100M12FT,100M13FT,100M14FT,100M15FT,100M16FT

  • Airtac 200M: Air Valve Manifold - 200M5FT Airtac 200M: Air Valve Manifold - 200M5FT - 2

    Airtac 200M series: pneumatic valve manifold base - 200M5FT

    Specifications Specifications: 200M5FT is an AirTAC 200M manifold with 5 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 5F 5 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 5 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 136 mm KA 126 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 136 mm KA 126 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 5F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 528.77 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • 200M4FT Airtac 200M: Air Valve Manifold - 200M4FT

    Airtac 200M series: pneumatic valve manifold base - 200M4FT

    Specifications Specifications: 200M4FT is an AirTAC 200M manifold with 4 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 4F 4 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 4 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 113 mm KA 103 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 113 mm KA 103 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 4F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 439.34 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • Airtac 100M: Air Valve Manifold - 100M3FT Airtac 100M: Air Valve Manifold - 100M3FT - 2

    Airtac 100M series: pneumatic valve manifold base - 100M3FT

    Specifications Specifications: 100M3FT is an AirTAC 100M manifold with 3 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 3F 3 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 3 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 76 mm KA 66 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 76 mm KA 66 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 3F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 259.58 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • 200M10FG

    Airtac 200M series: pneumatic valve manifold base - 200M10FG

    Specifications Specifications: 200M10FG is an AirTAC 200M manifold with 10 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 10F 10 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 10 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 251 mm KA 241 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 251 mm KA 241 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 10F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 975.89 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • Airtac 200M: Air Valve Manifold - 200M12FT Airtac 200M: Air Valve Manifold - 200M12FT - 2

    Airtac 200M series: pneumatic valve manifold base - 200M12FT

    Specifications Specifications: 200M12FT is an AirTAC 200M manifold with 12 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 12F 12 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 12 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 297 mm KA 287 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 297 mm KA 287 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 12F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1154.74 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • 200M13F Airtac 200M: Air Valve Manifold - 200M16F

    Airtac 200M series: pneumatic valve manifold base - 200M16F

    Specifications Specifications: 200M16F is an AirTAC 200M manifold with 16 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 16F 16 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 16 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 389 mm KA 379 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 389 mm KA 379 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 16F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1512.43 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • Airtac 200M series: pneumatic valve manifold base - 200M6FG Airtac 200M series: pneumatic valve manifold base - 200M6FG

    Airtac 200M series: pneumatic valve manifold base - 200M6FG

    Specifications Specifications: 200M6FG is an AirTAC 200M manifold with 6 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 6F 6 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 6 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 159 mm KA 149 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 159 mm KA 149 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 6F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 618.19 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 200M8FG

    Airtac 200M series: pneumatic valve manifold base - 200M8FG

    Specifications Specifications: 200M8FG is an AirTAC 200M manifold with 8 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 8F 8 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 8 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 205 mm KA 195 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 205 mm KA 195 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 8F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 797.04 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 200M9FG

    Airtac 200M series: pneumatic valve manifold base - 200M9FG

    Specifications Specifications: 200M9FG is an AirTAC 200M manifold with 9 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 9F 9 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 9 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 228 mm KA 218 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 228 mm KA 218 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 9F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 886.46 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 200M9FT

    Airtac 200M series: pneumatic valve manifold base - 200M9FT

    Specifications Specifications: 200M9FT is an AirTAC 200M manifold with 9 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 9F 9 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 9 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 228 mm KA 218 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 228 mm KA 218 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 9F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 886.46 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • Airtac 3V100M: Air Valve Manifold - 3V100M5F Airtac 3V100M: Air Valve Manifold - 3V100M5F - 2

    Airtac 3V100M series: pneumatic valve manifold base - 3V100M5F

    Specifications Specifications: 3V100M5F is an AirTAC 3V100M manifold with 5 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 3V100M 100 series manifold 5F 5 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 3V100 series 3V100M; explicit application table in the linked PDF and 2022 printed page 81 3A100 series 3V100M; explicit application table in 2022 printed page 122 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 3V100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 5 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 3V100 Parameter Details A 114 mm KA 104 mm B 131.5 mm BA 88.5 mm BC 22.7 mm C 81 mm CA 26 mm CB 27 mm D 39 mm E 32 mm F 19 mm G 19 mm H 30 mm K 4.5 mm KB 5 mm P 1/4 in PA 11.5 mm PB 22 mm Assembly Drawing Reference — 3A100 Parameter Details A 114 mm KA 104 mm B 70 mm BA 57.7 mm BC 22.7 mm C 53 mm CA 26 mm CB 27 mm D 39 mm E 32 mm F 19 mm G 19 mm H 30 mm K 4.5 mm KB 5 mm P 1/4 in PA 11.5 mm PB 22 mm The A and KA values shown are the printed 5F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-3V100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 312.11 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-3V100M-R2 closes an unused valve mounting station on 3V100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • Airtac 3V200M: Air Valve Manifold - 3V200M3FG Airtac 3V200M: Air Valve Manifold - 3V200M3FG - 2

    Airtac 3V200M series: pneumatic valve manifold base - 3V200M3FG

    Specifications Specifications: 3V200M3FG is an AirTAC 3V200M manifold with 3 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 3V200M 200 series manifold 3F 3 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 3V200 series 3V200M; explicit application table in the linked PDF and 2022 printed page 81 3A200 series 3V200M; explicit application table in 2022 printed page 122 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 3V200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 3 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 3V200 Parameter Details A 92 mm KA 80 mm B 162.5 mm BA 109 mm BC 27.7 mm C 92.5 mm CA 26 mm CB 35 mm D 45 mm E 40 mm F 23 mm G 23 mm H 35 mm K 4.5 mm KB 6 mm P 1/4 in PA 11.5 mm PB 25 mm Assembly Drawing Reference — 3A200 Parameter Details A 92 mm KA 80 mm B 84 mm BA 69.7 mm BC 27.7 mm C 61 mm CA 26 mm CB 35 mm D 45 mm E 40 mm F 23 mm G 23 mm H 35 mm K 4.5 mm KB 6 mm P 1/4 in PA 11.5 mm PB 25 mm The A and KA values shown are the printed 3F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-3V200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 290.63 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-3V200M-R2 closes an unused valve mounting station on 3V200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • Airtac 3V300M: Air Valve Manifold - 3V300M5FG Airtac 3V300M: Air Valve Manifold - 3V300M5FG - 2

    Airtac 3V300M series: pneumatic valve manifold base - 3V300M5FG

    Specifications Specifications: 3V300M5FG is an AirTAC 3V300M manifold with 5 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 3V300M 300 series manifold 5F 5 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 3V300 series 3V300M; explicit application table in the linked PDF and 2022 printed page 81 3A300 series 3V300M; explicit application table in 2022 printed page 122 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 3V300M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 5 Common port nominal size 3/8 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 3V300 Parameter Details A 166 mm KA 154 mm B 175 mm BA 120 mm BC 32.5 mm C 99 mm CA 30 mm CB 40 mm D 52 mm E 47 mm F 28 mm G 27 mm H 42 mm K 4.5 mm KB 6 mm P 3/8 in PA 13.5 mm PB 28 mm Assembly Drawing Reference — 3A300 Parameter Details A 166 mm KA 154 mm B 96 mm BA 80.5 mm BC 32.5 mm C 70 mm CA 30 mm CB 40 mm D 52 mm E 47 mm F 28 mm G 27 mm H 42 mm K 4.5 mm KB 6 mm P 3/8 in PA 13.5 mm PB 28 mm The A and KA values shown are the printed 5F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-3V300M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 699.19 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-3V300M-R2 closes an unused valve mounting station on 3V300M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G3/8). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC30010G,GAFR30010SG,GAFR40010SG BP,BR male G3/8 ↔ male G1/8: GBB0103male G3/8 ↔ male G1/4: GBB0203male G3/8 ↔ male G3/8: GBB0303male G1/2 ↔ male G3/8: GBB0304male G3/8 ↔ female G1/8: GBD0103male G3/8 ↔ female G1/4: GBD02036 × 4: GBKC0604-03,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-03,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0310 × 6.5: GBKC1065-03,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0312 × 8: GBKC1208-03,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0310: GBPC1003,GPC1003,GPC1003D,GPEB1003,GPEB1003D,GPED1003,GPED1003D,GPH1003,GPH1003D,GPHF1003,GPHF1003D,GPHW1003,GPHW1003D,GPL1003,GPL1003D,GPLL1003,GPLL1003D,GPSA10,GPSA10D,GPSS1003A,GPSS1003AD,GPSS1003B,GPSS1003BD,GPTL1003A,GPTL1003AD,GPTL1003B,GPTL1003BD,GPYB1003,GPYB1003D,GPZB1003,GPZB1003D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1203,GPC1203,GPC1203D,GPEB1203,GPEB1203D,GPED1203,GPED1203D,GPH1203,GPH1203D,GPHF1203,GPHF1203D,GPHW1203,GPHW1203D,GPL1203,GPL1203D,GPLL1203,GPLL1203D,GPSA12,GPSA12D,GPSS1203A,GPSS1203AD,GPSS1203B,GPSS1203BD,GPTL1203A,GPTL1203AD,GPTL1203B,GPTL1203BD,GPYB1203,GPYB1203D,GPZB1203,GPZB1203D,PSA12,PSA12-S,PSA12D,PSA12D-S6: GBPC603,GPC603,GPC603D,GPEB603,GPEB603D,GPED603,GPED603D,GPH603,GPH603D,GPHF603,GPHF603D,GPHW603,GPHW603D,GPL603,GPL603D,GPLL603,GPLL603D,GPSA6,GPSA6D,GPTL603A,GPTL603AD,GPTL603B,GPTL603BD,GPYB603,GPYB603D,GPZB603,GPZB603D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC803,GPC803,GPC803D,GPEB803,GPEB803D,GPED803,GPED803D,GPH803,GPH803D,GPHF803,GPHF803D,GPHW803,GPHW803D,GPL803,GPL803D,GPLL803,GPLL803D,GPSA8,GPSA8D,GPTL803A,GPTL803AD,GPTL803B,GPTL803BD,GPYB803,GPYB803D,GPZB803,GPZB803D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 10 / branch 8: GPKD10-803,GPKD10-803D BR GBESL03,GBSL03,GBSLM0310: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G3/8 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 3/8: 0.24 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • P-400M-R2

    Airtac P-400M series: manifold blanking plate kit - P-400M-R2

    Specifications Specifications: P-400M-R2 is the AirTAC blank-plate kit for the 400M manifold size. It closes an unused valve mounting station on that manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model P Accessory kit 400M 400 series manifold R2 Blank plate for manifold Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V400 series 400M; explicit application table in 2022 printed page 82 5V400 series 400M; explicit application table in 2022 printed page 82 4A400 series 400M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Blank-plate accessory kit Matching manifold 400M Published station range 1–8 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C Construction and Kit Contents Blank-plate kits list a blank plate and screws. The catalog lists a blank plate and screws for this accessory kit, but does not specify the screw quantity or provide a separate dimension table for the loose plate. R2 identifies the blank-plate accessory type, not a quantity of two. The blank-plate kit has a separate ordering code from the manifold. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A400 Parameter Details A 61 + 35 x (station count − 1) mm KA 49 + 35 x (station count − 1) mm B 163 mm BA 142 mm BC 128 mm BD 57 mm C 83 mm CA 33 mm CB 50 mm D 100 mm E 94 mm F 35 mm G 30.5 mm H 75 mm K 5.5 mm KB 6 mm KC 32 mm P 1/2 in PA 15 mm PB 68 mm Assembly Drawing Reference — 4V400 Parameter Details A 61 + 35 x (station count − 1) mm KA 49 + 35 x (station count − 1) mm B 243 mm BA 223 mm BC 168.5 mm BD 57 mm C 107 mm CA 33 mm CB 50 mm D 100 mm E 94 mm F 35 mm G 30.5 mm H 75 mm K 5.5 mm KB 6 mm KC 32 mm P 1/2 in PA 15 mm PB 68 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. A and KA depend on the chosen 400M manifold station count, from 1 to 8. The formulas shown are the progression of the published station table, not dimensions assigned to the loose blank plate. The reviewed catalog does not give a separate dimension table for the blank plate itself. Ordering Notes The matching blank-plate kit is P-400M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 20 g. The mass reference is the DOLD listing for P-400M-R2, which lists an item weight of 20 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The mass reference is for the independently listed accessory, not for its valve or manifold. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions The base options below match this 400M blanking plate; their thread codes describe common supply/exhaust ports, not a thread on the plate. Order the base and valves separately. Base kits contain the manifold, sealing gasket and screws; component quantities are not specified. Use the matching size-family drawing and sealing surfaces. Item Complete codes and use Matching 400M base, PT 400M with PT 1/2 common supply/exhaust ports; select 1–8 stations within this same size family.400M1F,400M2F,400M3F,400M4F,400M5F,400M6F,400M7F,400M8F Matching 400M base, G 400M with G 1/2 common supply/exhaust ports; select 1–8 stations within this same size family.400M1FG,400M2FG,400M3FG,400M4FG,400M5FG,400M6FG,400M7FG,400M8FG Matching 400M base, NPT 400M with NPT 1/2 common supply/exhaust ports; select 1–8 stations within this same size family.400M1FT,400M2FT,400M3FT,400M4FT,400M5FT,400M6FT,400M7FT,400M8FT

  • 100M2F Airtac 100M: Air Valve Manifold - 100M2F

    Airtac 100M series: pneumatic valve manifold base - 100M2F

    Specifications Specifications: 100M2F is an AirTAC 100M manifold with 2 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 2F 2 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 2 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 57 mm KA 47 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 57 mm KA 47 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 2F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 194.68 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 300M3FT Airtac 300M: Air Valve Manifold - 300M3FT

    Airtac 300M series: pneumatic valve manifold base - 300M3FT

    Specifications Specifications: 300M3FT is an AirTAC 300M manifold with 3 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 300M 300 series manifold 3F 3 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V300 series 300M; explicit application table in 2022 printed page 82 5V300 series 300M; explicit application table in 2022 printed page 82 4A300 series 300M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 300M Published station range 1–12 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 3 Common port nominal size 3/8 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A300 Parameter Details A 108 mm KA 98 mm B 130 mm BA 111 mm BC 95.5 mm BD 40 mm C 68 mm CA 28 mm CB 40 mm D 75 mm E 64 mm F 28 mm G 26 mm H 54 mm K 4.5 mm KB 5 mm KC 26 mm P 3/8 in PA 13.5 mm PB 53 mm Assembly Drawing Reference — 4V300 Parameter Details A 108 mm KA 98 mm B 208 mm BA 190 mm BC 135 mm BD 40 mm C 97 mm CA 28 mm CB 40 mm D 75 mm E 64 mm F 28 mm G 26 mm H 54 mm K 4.5 mm KB 5 mm KC 26 mm P 3/8 in PA 13.5 mm PB 53 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 3F station-count entries. Station counts above 12 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-300M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 612.36 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-300M-R2 closes an unused valve mounting station on 300M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT3/8). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC30010T,GAFR30010ST,GAFR40010ST BP,BR (discontinued) male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT3/8 ↔ male NPT1/8: NBB1/8-3/8male NPT1/2 ↔ male NPT3/8: NBB3/8-1/2male NPT3/8 ↔ male NPT3/8: NBB3/8-3/8male NPT3/8 ↔ female NPT1/4: NBD1/4-3/8male NPT3/8 ↔ female NPT1/8: NBD1/8-3/81/2 × 1/3 in: NBKC1/2-1/3-3/81/4 × 5/32 in: NBKC1/4-5/32-3/83/8 × 1/4 in: NBKC3/8-1/4-3/85/16 × 1/5 in: NBKC5/16-1/5-3/81/2 in: NBPC1/2-3/8,NPH1/2-3/8,NPHF1/2-3/8,NPHW1/2-3/8,NPLL1/2-3/8,NPSS1/2-3/8A,NPSS1/2-3/8B,NPZB1/2-3/81/4 in: NBPC1/4-3/8,NPH1/4-3/8,NPHF1/4-3/8,NPHW1/4-3/8,NPLL1/4-3/8,NPZB1/4-3/83/8 in: NBPC3/8-3/8,NPH3/8-3/8,NPHF3/8-3/8,NPHW3/8-3/8,NPLL3/8-3/8,NPSS3/8-3/8A,NPSS3/8-3/8B,NPZB3/8-3/85/16 in: NBPC5/16-3/8,NPH5/16-3/8,NPHF5/16-3/8,NPHW5/16-3/8,NPLL5/16-3/8,NPZB5/16-3/8main 3/8 / branch 5/16 in: NPKD3/8-5/16-3/8 BR (discontinued) NBESL3/8 BR NBSL3/8,NBSLM3/8 BP,BR 1/2 in: NPC1/2-3/8,NPEB1/2-3/8,NPED1/2-3/8,NPL1/2-3/8,NPSA1/2,NPTL1/2-3/8A,NPTL1/2-3/8B,NPYB1/2-3/81/4 in: NPC1/4-3/8,NPEB1/4-3/8,NPED1/4-3/8,NPL1/4-3/8,NPSA1/4,NPTL1/4-3/8A,NPTL1/4-3/8B,NPYB1/4-3/83/8 in: NPC3/8-3/8,NPEB3/8-3/8,NPED3/8-3/8,NPL3/8-3/8,NPSA3/8,NPTL3/8-3/8A,NPTL3/8-3/8B,NPYB3/8-3/85/16 in: NPC5/16-3/8,NPEB5/16-3/8,NPED5/16-3/8,NPL5/16-3/8,NPSA5/16,NPTL5/16-3/8A,NPTL5/16-3/8B,NPYB5/16-3/8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT3/8 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 3/8: 0.24 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • Airtac 3V300M: Air Valve Manifold - 3V300M2FT Airtac 3V300M: Air Valve Manifold - 3V300M2FT - 2

    Airtac 3V300M series: pneumatic valve manifold base - 3V300M2FT

    Specifications Specifications: 3V300M2FT is an AirTAC 3V300M manifold with 2 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 3V300M 300 series manifold 2F 2 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 3V300 series 3V300M; explicit application table in the linked PDF and 2022 printed page 81 3A300 series 3V300M; explicit application table in 2022 printed page 122 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 3V300M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 2 Common port nominal size 3/8 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 3V300 Parameter Details A 82 mm KA 70 mm B 175 mm BA 120 mm BC 32.5 mm C 99 mm CA 30 mm CB 40 mm D 52 mm E 47 mm F 28 mm G 27 mm H 42 mm K 4.5 mm KB 6 mm P 3/8 in PA 13.5 mm PB 28 mm Assembly Drawing Reference — 3A300 Parameter Details A 82 mm KA 70 mm B 96 mm BA 80.5 mm BC 32.5 mm C 70 mm CA 30 mm CB 40 mm D 52 mm E 47 mm F 28 mm G 27 mm H 42 mm K 4.5 mm KB 6 mm P 3/8 in PA 13.5 mm PB 28 mm The A and KA values shown are the printed 2F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-3V300M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 345.38 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-3V300M-R2 closes an unused valve mounting station on 3V300M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT3/8). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC30010T,GAFR30010ST,GAFR40010ST BP,BR (discontinued) male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT3/8 ↔ male NPT1/8: NBB1/8-3/8male NPT1/2 ↔ male NPT3/8: NBB3/8-1/2male NPT3/8 ↔ male NPT3/8: NBB3/8-3/8male NPT3/8 ↔ female NPT1/4: NBD1/4-3/8male NPT3/8 ↔ female NPT1/8: NBD1/8-3/81/2 × 1/3 in: NBKC1/2-1/3-3/81/4 × 5/32 in: NBKC1/4-5/32-3/83/8 × 1/4 in: NBKC3/8-1/4-3/85/16 × 1/5 in: NBKC5/16-1/5-3/81/2 in: NBPC1/2-3/8,NPH1/2-3/8,NPHF1/2-3/8,NPHW1/2-3/8,NPLL1/2-3/8,NPSS1/2-3/8A,NPSS1/2-3/8B,NPZB1/2-3/81/4 in: NBPC1/4-3/8,NPH1/4-3/8,NPHF1/4-3/8,NPHW1/4-3/8,NPLL1/4-3/8,NPZB1/4-3/83/8 in: NBPC3/8-3/8,NPH3/8-3/8,NPHF3/8-3/8,NPHW3/8-3/8,NPLL3/8-3/8,NPSS3/8-3/8A,NPSS3/8-3/8B,NPZB3/8-3/85/16 in: NBPC5/16-3/8,NPH5/16-3/8,NPHF5/16-3/8,NPHW5/16-3/8,NPLL5/16-3/8,NPZB5/16-3/8main 3/8 / branch 5/16 in: NPKD3/8-5/16-3/8 BR (discontinued) NBESL3/8 BR NBSL3/8,NBSLM3/8 BP,BR 1/2 in: NPC1/2-3/8,NPEB1/2-3/8,NPED1/2-3/8,NPL1/2-3/8,NPSA1/2,NPTL1/2-3/8A,NPTL1/2-3/8B,NPYB1/2-3/81/4 in: NPC1/4-3/8,NPEB1/4-3/8,NPED1/4-3/8,NPL1/4-3/8,NPSA1/4,NPTL1/4-3/8A,NPTL1/4-3/8B,NPYB1/4-3/83/8 in: NPC3/8-3/8,NPEB3/8-3/8,NPED3/8-3/8,NPL3/8-3/8,NPSA3/8,NPTL3/8-3/8A,NPTL3/8-3/8B,NPYB3/8-3/85/16 in: NPC5/16-3/8,NPEB5/16-3/8,NPED5/16-3/8,NPL5/16-3/8,NPSA5/16,NPTL5/16-3/8A,NPTL5/16-3/8B,NPYB5/16-3/8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT3/8 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 3/8: 0.24 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • 100M4FT

    Airtac 100M series: pneumatic valve manifold base - 100M4FT

    Specifications Specifications: 100M4FT is an AirTAC 100M manifold with 4 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 4F 4 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 4 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 95 mm KA 85 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 95 mm KA 85 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 4F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 324.47 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.


You have seen 24 out of 306 products

Footer image

© 2026 Airtac, Powered by Shopify

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • Amazon
  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • USDC
  • Visa