306 products

AIRTAC 3V1 Series Solenoid Valve

AIRTAC 3V1 Series Solenoid Valve

  • Product Features
  • Specifications
  • Electrical Specifications
  • Product Ordering Code

Product Features

  • Direct acting normally closed type, with sensitive commutation.
  • No need for lubrication.
  • Can be used with multiple integrated valves (manifold), saving installation space.
  • Equipped with a manual override, convenient for installation and debugging.
  • Multiple standard voltage levels are available for selection.

Specifications

Item 3V1-M5 3V1-06
Working Medium Air (filtered through 40µm filter or finer)
Operation Type Direct Acting
Port Size [Note 1] M5 PT1/8
Positions Three-way Two-position
Lubrication No need
Operating Pressure Range 0~0.8MPa (0~114psi)
Proof Pressure 1.2MPa (175psi)
Working Temperature -20~70°C
Effective Orifice Φ1.2mm
Body Material Aluminum Alloy
[Note 1] G thread and NPT thread are optional for port thread type.

Electrical Specifications

Item AC220V AC110V AC24V DC24V DC12V
Standard Voltage AC220V AC110V AC24V DC24V DC12V
Operating Voltage Range AC: ±15% DC: ±10%
Power Consumption 4.5VA 4.5VA 5.0VA 3.0W 2.5W
Protection Degree IP65 (DIN40050)
Insulation Class B Class
Wiring Form DIN Socket Type, Lead Wire Type
Excitation Time Below 0.05 seconds
Maximum Operating Frequency [Note 1] 10 times/second
[Note 1] The maximum operating frequency is for the air condition.

Product Ordering Code

Example Code: 3V 1 06 A    3F   

1. Model Code 2. Series Code 3. Port Size 4. Standard Voltage 5. Wiring Form 6. Connection Quantity 7. Thread Type Code
3V: Three-way Two-position Solenoid Valve 1: 1 Series M5: M5 A: AC220V Blank: DIN Socket Type 1F: 1 Connection No Code (for M5 port)
06: 1/8" B: DC24V I: Lead Wire Type [Note] 2F: 2 Connections Blank: PT Thread
C: AC110V 3F: 3 Connections G: G Thread
E: AC24V ... T: NPT Thread
F: DC12V 20F: 20 Connections
Note: The standard wire length for the lead-wire type is 0.5m.
  • 300M10F

    Airtac 300M series: pneumatic valve manifold base - 300M10F

    Specifications Specifications: 300M10F is an AirTAC 300M manifold with 10 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 300M 300 series manifold 10F 10 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V300 series 300M; explicit application table in 2022 printed page 82 5V300 series 300M; explicit application table in 2022 printed page 82 4A300 series 300M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 300M Published station range 1–12 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 10 Common port nominal size 3/8 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A300 Parameter Details A 304 mm KA 294 mm B 130 mm BA 111 mm BC 95.5 mm BD 40 mm C 68 mm CA 28 mm CB 40 mm D 75 mm E 64 mm F 28 mm G 26 mm H 54 mm K 4.5 mm KB 5 mm KC 26 mm P 3/8 in PA 13.5 mm PB 53 mm Assembly Drawing Reference — 4V300 Parameter Details A 304 mm KA 294 mm B 208 mm BA 190 mm BC 135 mm BD 40 mm C 97 mm CA 28 mm CB 40 mm D 75 mm E 64 mm F 28 mm G 26 mm H 54 mm K 4.5 mm KB 5 mm KC 26 mm P 3/8 in PA 13.5 mm PB 53 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 10F station-count entries. Station counts above 12 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-300M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1723.68 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-300M-R2 closes an unused valve mounting station on 300M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT3/8). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC30010,GAFR30010S,GAFR40010S BP,BR male PT3/8 ↔ male PT1/8: BB0103,BB0103-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT3/8 ↔ male PT3/8: BB0303,BB0303-Smale PT1/2 ↔ male PT3/8: BB0304,BB0304-Smale PT3/8 ↔ female PT1/8: BD0103,BD0103-Smale PT3/8 ↔ female PT1/4: BD0203,BD0203-S6 × 4: BKC0604-03,BKC0604-03-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-03,BKC0805-03-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-03,BKC0806-03-S10 × 6.5: BKC1065-03,BKC1065-03-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-03,BKC1075-03-S12 × 8: BKC1208-03,BKC1208-03-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-03,BKC1209-03-S10: BPC1003,BPOC1003,GPSA10,GPSA10D,PC1003,PC1003-S,PC1003D,PC1003D-S,PEB1003,PEB1003-S,PEB1003D,PEB1003D-S,PED1003,PED1003-S,PED1003D,PED1003D-S,PH1003,PH1003-S,PH1003D,PH1003D-S,PHF1003,PHF1003-S,PHF1003D,PHF1003D-S,PHW1003,PHW1003-S,PHW1003D,PHW1003D-S,PL1003,PL1003-S,PL1003D,PL1003D-S,PLL1003,PLL1003-S,PLL1003D,PLL1003D-S,POC1003,POC1003-S,POC1003D,POC1003D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1003A,PSL1003A-S,PSL1003AD,PSL1003AD-S,PSL1003B,PSL1003B-S,PSL1003BD,PSL1003BD-S,PSS1003A,PSS1003A-S,PSS1003AD,PSS1003AD-S,PSS1003B,PSS1003B-S,PSS1003BD,PSS1003BD-S,PTL1003A,PTL1003AD,PTL1003B,PTL1003BD,PYB1003,PYB1003-S,PYB1003D,PYB1003D-S,PZB1003,PZB1003-S,PZB1003D,PZB1003D-S12: BPC1203,BPOC1203,GPSA12,GPSA12D,PC1203,PC1203-S,PC1203D,PC1203D-S,PEB1203,PEB1203-S,PEB1203D,PEB1203D-S,PED1203,PED1203-S,PED1203D,PED1203D-S,PH1203,PH1203-S,PH1203D,PH1203D-S,PHF1203,PHF1203-S,PHF1203D,PHF1203D-S,PHW1203,PHW1203-S,PHW1203D,PHW1203D-S,PL1203,PL1203-S,PL1203D,PL1203D-S,PLL1203,PLL1203-S,PLL1203D,PLL1203D-S,POC1203,POC1203-S,POC1203D,POC1203D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PSL1203A,PSL1203A-S,PSL1203AD,PSL1203AD-S,PSL1203B,PSL1203B-S,PSL1203BD,PSL1203BD-S,PSS1203A,PSS1203A-S,PSS1203AD,PSS1203AD-S,PSS1203B,PSS1203B-S,PSS1203BD,PSS1203BD-S,PTL1203A,PTL1203AD,PTL1203B,PTL1203BD,PYB1203,PYB1203-S,PYB1203D,PYB1203D-S,PZB1203,PZB1203-S,PZB1203D,PZB1203D-S6: BPC603,GPSA6,GPSA6D,PC603,PC603-S,PC603D,PC603D-S,PEB603,PEB603-S,PEB603D,PEB603D-S,PED603,PED603-S,PED603D,PED603D-S,PH603,PH603-S,PH603D,PH603D-S,PHF603,PHF603-S,PHF603D,PHF603D-S,PHW603,PHW603-S,PHW603D,PHW603D-S,PL603,PL603-S,PL603D,PL603D-S,PLL603,PLL603-S,PLL603D,PLL603D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL603A,PSL603A-S,PSL603AD,PSL603AD-S,PSL603B,PSL603B-S,PSL603BD,PSL603BD-S,PTL603A,PTL603AD,PTL603B,PTL603BD,PYB603,PYB603-S,PYB603D,PYB603D-S,PZB603,PZB603-S,PZB603D,PZB603D-S8: BPC803,GPSA8,GPSA8D,PC803,PC803-S,PC803D,PC803D-S,PEB803,PEB803-S,PEB803D,PEB803D-S,PED803,PED803-S,PED803D,PED803D-S,PH803,PH803-S,PH803D,PH803D-S,PHF803,PHF803-S,PHF803D,PHF803D-S,PHW803,PHW803-S,PHW803D,PHW803D-S,PL803,PL803-S,PL803D,PL803D-S,PLL803,PLL803-S,PLL803D,PLL803D-S,POC803,POC803-S,POC803D,POC803D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL803A,PSL803A-S,PSL803AD,PSL803AD-S,PSL803B,PSL803B-S,PSL803BD,PSL803BD-S,PTL803A,PTL803AD,PTL803B,PTL803BD,PYB803,PYB803-S,PYB803D,PYB803D-S,PZB803,PZB803-S,PZB803D,PZB803D-Smain 10 / branch 8: PKD10-803,PKD10-803-S,PKD10-803D,PKD10-803D-S BR BESL03,BESL03-S,BSL03,BSL03-S,BSLM03,BSLM03-S,PAL03,PAL03D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT3/8 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 3/8: 0.24 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 200M13F

    Airtac 200M series: pneumatic valve manifold base - 200M13F

    Specifications Specifications: 200M13F is an AirTAC 200M manifold with 13 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 13F 13 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 13 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 320 mm KA 310 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 320 mm KA 310 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 13F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1244.16 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 200M10F

    Airtac 200M series: pneumatic valve manifold base - 200M10F

    Specifications Specifications: 200M10F is an AirTAC 200M manifold with 10 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 200M 200 series manifold 10F 10 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V200 series 200M; explicit application table in 2022 printed page 82 5V200 series 200M; explicit application table in 2022 printed page 82 4A200 series 200M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 10 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A200 Parameter Details A 251 mm KA 241 mm B 111 mm BA 92 mm BC 77.7 mm BD 31.7 mm C 59 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm Assembly Drawing Reference — 4V200 Parameter Details A 251 mm KA 241 mm B 189 mm BA 171 mm BC 117 mm BD 31.7 mm C 91 mm CA 24 mm CB 35 mm D 60 mm E 52 mm F 23 mm G 22 mm H 38 mm K 4.5 mm KB 5 mm KC 21 mm P 1/4 in PA 10 mm PB 42 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 10F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 975.89 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-200M-R2 closes an unused valve mounting station on 200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • Airtac 3V300M: Air Valve Manifold - 3V300M10F

    Airtac 3V300M series: pneumatic valve manifold base - 3V300M10F

    Specifications Specifications: 3V300M10F is an AirTAC 3V300M manifold with 10 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 3V300M 300 series manifold 10F 10 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 3V300 series 3V300M; explicit application table in the linked PDF and 2022 printed page 81 3A300 series 3V300M; explicit application table in 2022 printed page 122 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 3V300M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 10 Common port nominal size 3/8 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 3V300 Parameter Details A 306 mm KA 294 mm B 175 mm BA 120 mm BC 32.5 mm C 99 mm CA 30 mm CB 40 mm D 52 mm E 47 mm F 28 mm G 27 mm H 42 mm K 4.5 mm KB 6 mm P 3/8 in PA 13.5 mm PB 28 mm Assembly Drawing Reference — 3A300 Parameter Details A 306 mm KA 294 mm B 96 mm BA 80.5 mm BC 32.5 mm C 70 mm CA 30 mm CB 40 mm D 52 mm E 47 mm F 28 mm G 27 mm H 42 mm K 4.5 mm KB 6 mm P 3/8 in PA 13.5 mm PB 28 mm The A and KA values shown are the printed 10F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-3V300M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1288.87 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-3V300M-R2 closes an unused valve mounting station on 3V300M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT3/8). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC30010,GAFR30010S,GAFR40010S BP,BR male PT3/8 ↔ male PT1/8: BB0103,BB0103-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT3/8 ↔ male PT3/8: BB0303,BB0303-Smale PT1/2 ↔ male PT3/8: BB0304,BB0304-Smale PT3/8 ↔ female PT1/8: BD0103,BD0103-Smale PT3/8 ↔ female PT1/4: BD0203,BD0203-S6 × 4: BKC0604-03,BKC0604-03-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-03,BKC0805-03-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-03,BKC0806-03-S10 × 6.5: BKC1065-03,BKC1065-03-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-03,BKC1075-03-S12 × 8: BKC1208-03,BKC1208-03-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-03,BKC1209-03-S10: BPC1003,BPOC1003,GPSA10,GPSA10D,PC1003,PC1003-S,PC1003D,PC1003D-S,PEB1003,PEB1003-S,PEB1003D,PEB1003D-S,PED1003,PED1003-S,PED1003D,PED1003D-S,PH1003,PH1003-S,PH1003D,PH1003D-S,PHF1003,PHF1003-S,PHF1003D,PHF1003D-S,PHW1003,PHW1003-S,PHW1003D,PHW1003D-S,PL1003,PL1003-S,PL1003D,PL1003D-S,PLL1003,PLL1003-S,PLL1003D,PLL1003D-S,POC1003,POC1003-S,POC1003D,POC1003D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1003A,PSL1003A-S,PSL1003AD,PSL1003AD-S,PSL1003B,PSL1003B-S,PSL1003BD,PSL1003BD-S,PSS1003A,PSS1003A-S,PSS1003AD,PSS1003AD-S,PSS1003B,PSS1003B-S,PSS1003BD,PSS1003BD-S,PTL1003A,PTL1003AD,PTL1003B,PTL1003BD,PYB1003,PYB1003-S,PYB1003D,PYB1003D-S,PZB1003,PZB1003-S,PZB1003D,PZB1003D-S12: BPC1203,BPOC1203,GPSA12,GPSA12D,PC1203,PC1203-S,PC1203D,PC1203D-S,PEB1203,PEB1203-S,PEB1203D,PEB1203D-S,PED1203,PED1203-S,PED1203D,PED1203D-S,PH1203,PH1203-S,PH1203D,PH1203D-S,PHF1203,PHF1203-S,PHF1203D,PHF1203D-S,PHW1203,PHW1203-S,PHW1203D,PHW1203D-S,PL1203,PL1203-S,PL1203D,PL1203D-S,PLL1203,PLL1203-S,PLL1203D,PLL1203D-S,POC1203,POC1203-S,POC1203D,POC1203D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PSL1203A,PSL1203A-S,PSL1203AD,PSL1203AD-S,PSL1203B,PSL1203B-S,PSL1203BD,PSL1203BD-S,PSS1203A,PSS1203A-S,PSS1203AD,PSS1203AD-S,PSS1203B,PSS1203B-S,PSS1203BD,PSS1203BD-S,PTL1203A,PTL1203AD,PTL1203B,PTL1203BD,PYB1203,PYB1203-S,PYB1203D,PYB1203D-S,PZB1203,PZB1203-S,PZB1203D,PZB1203D-S6: BPC603,GPSA6,GPSA6D,PC603,PC603-S,PC603D,PC603D-S,PEB603,PEB603-S,PEB603D,PEB603D-S,PED603,PED603-S,PED603D,PED603D-S,PH603,PH603-S,PH603D,PH603D-S,PHF603,PHF603-S,PHF603D,PHF603D-S,PHW603,PHW603-S,PHW603D,PHW603D-S,PL603,PL603-S,PL603D,PL603D-S,PLL603,PLL603-S,PLL603D,PLL603D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL603A,PSL603A-S,PSL603AD,PSL603AD-S,PSL603B,PSL603B-S,PSL603BD,PSL603BD-S,PTL603A,PTL603AD,PTL603B,PTL603BD,PYB603,PYB603-S,PYB603D,PYB603D-S,PZB603,PZB603-S,PZB603D,PZB603D-S8: BPC803,GPSA8,GPSA8D,PC803,PC803-S,PC803D,PC803D-S,PEB803,PEB803-S,PEB803D,PEB803D-S,PED803,PED803-S,PED803D,PED803D-S,PH803,PH803-S,PH803D,PH803D-S,PHF803,PHF803-S,PHF803D,PHF803D-S,PHW803,PHW803-S,PHW803D,PHW803D-S,PL803,PL803-S,PL803D,PL803D-S,PLL803,PLL803-S,PLL803D,PLL803D-S,POC803,POC803-S,POC803D,POC803D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL803A,PSL803A-S,PSL803AD,PSL803AD-S,PSL803B,PSL803B-S,PSL803BD,PSL803BD-S,PTL803A,PTL803AD,PTL803B,PTL803BD,PYB803,PYB803-S,PYB803D,PYB803D-S,PZB803,PZB803-S,PZB803D,PZB803D-Smain 10 / branch 8: PKD10-803,PKD10-803-S,PKD10-803D,PKD10-803D-S BR BESL03,BESL03-S,BSL03,BSL03-S,BSLM03,BSLM03-S,PAL03,PAL03D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT3/8 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 3/8: 0.24 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • Airtac 3V200M: Air Valve Manifold - 3V200M10F

    Airtac 3V200M series: pneumatic valve manifold base - 3V200M10F

    Specifications Specifications: 3V200M10F is an AirTAC 3V200M manifold with 10 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 3V200M 200 series manifold 10F 10 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 3V200 series 3V200M; explicit application table in the linked PDF and 2022 printed page 81 3A200 series 3V200M; explicit application table in 2022 printed page 122 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 3V200M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 10 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 3V200 Parameter Details A 253 mm KA 241 mm B 162.5 mm BA 109 mm BC 27.7 mm C 92.5 mm CA 26 mm CB 35 mm D 45 mm E 40 mm F 23 mm G 23 mm H 35 mm K 4.5 mm KB 6 mm P 1/4 in PA 11.5 mm PB 25 mm Assembly Drawing Reference — 3A200 Parameter Details A 253 mm KA 241 mm B 84 mm BA 69.7 mm BC 27.7 mm C 61 mm CA 26 mm CB 35 mm D 45 mm E 40 mm F 23 mm G 23 mm H 35 mm K 4.5 mm KB 6 mm P 1/4 in PA 11.5 mm PB 25 mm The A and KA values shown are the printed 10F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-3V200M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 799.23 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-3V200M-R2 closes an unused valve mounting station on 3V200M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M10F

    Airtac 100M series: pneumatic valve manifold base - 100M10F

    Specifications Specifications: 100M10F is an AirTAC 100M manifold with 10 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 10F 10 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 10 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 209 mm KA 199 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 209 mm KA 199 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 10F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 713.84 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M11F

    Airtac 100M series: pneumatic valve manifold base - 100M11F

    Specifications Specifications: 100M11F is an AirTAC 100M manifold with 11 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 11F 11 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 11 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 228 mm KA 218 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 228 mm KA 218 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 11F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 778.73 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M11FG

    Airtac 100M series: pneumatic valve manifold base - 100M11FG

    Specifications Specifications: 100M11FG is an AirTAC 100M manifold with 11 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 11F 11 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 11 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 228 mm KA 218 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 228 mm KA 218 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 11F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 778.73 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M12F

    Airtac 100M series: pneumatic valve manifold base - 100M12F

    Specifications Specifications: 100M12F is an AirTAC 100M manifold with 12 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 12F 12 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 12 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 247 mm KA 237 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 247 mm KA 237 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 12F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 843.63 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M12FG

    Airtac 100M series: pneumatic valve manifold base - 100M12FG

    Specifications Specifications: 100M12FG is an AirTAC 100M manifold with 12 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 12F 12 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 12 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 247 mm KA 237 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 247 mm KA 237 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 12F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 843.63 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M12FT

    Airtac 100M series: pneumatic valve manifold base - 100M12FT

    Specifications Specifications: 100M12FT is an AirTAC 100M manifold with 12 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 12F 12 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 12 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 247 mm KA 237 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 247 mm KA 237 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 12F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 843.63 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • 100M13F

    Airtac 100M series: pneumatic valve manifold base - 100M13F

    Specifications Specifications: 100M13F is an AirTAC 100M manifold with 13 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 13F 13 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 13 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 266 mm KA 256 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 266 mm KA 256 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 13F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 908.52 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M13FG

    Airtac 100M series: pneumatic valve manifold base - 100M13FG

    Specifications Specifications: 100M13FG is an AirTAC 100M manifold with 13 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 13F 13 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 13 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 266 mm KA 256 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 266 mm KA 256 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 13F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 908.52 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M13FT

    Airtac 100M series: pneumatic valve manifold base - 100M13FT

    Specifications Specifications: 100M13FT is an AirTAC 100M manifold with 13 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 13F 13 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 13 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 266 mm KA 256 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 266 mm KA 256 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 13F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 908.52 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • 100M14F

    Airtac 100M series: pneumatic valve manifold base - 100M14F

    Specifications Specifications: 100M14F is an AirTAC 100M manifold with 14 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 14F 14 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 14 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 285 mm KA 275 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 285 mm KA 275 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 14F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 973.42 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M14FG

    Airtac 100M series: pneumatic valve manifold base - 100M14FG

    Specifications Specifications: 100M14FG is an AirTAC 100M manifold with 14 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 14F 14 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 14 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 285 mm KA 275 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 285 mm KA 275 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 14F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 973.42 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M15F

    Airtac 100M series: pneumatic valve manifold base - 100M15F

    Specifications Specifications: 100M15F is an AirTAC 100M manifold with 15 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 15F 15 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 15 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 304 mm KA 294 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 304 mm KA 294 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 15F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1038.31 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M15FG

    Airtac 100M series: pneumatic valve manifold base - 100M15FG

    Specifications Specifications: 100M15FG is an AirTAC 100M manifold with 15 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 15F 15 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 15 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 304 mm KA 294 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 304 mm KA 294 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 15F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1038.31 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M15FT

    Airtac 100M series: pneumatic valve manifold base - 100M15FT

    Specifications Specifications: 100M15FT is an AirTAC 100M manifold with 15 mounting stations and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 15F 15 valve mounting stations T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 15 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 304 mm KA 294 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 304 mm KA 294 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 15F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1038.31 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.

  • 100M16F

    Airtac 100M series: pneumatic valve manifold base - 100M16F

    Specifications Specifications: 100M16F is an AirTAC 100M manifold with 16 mounting stations and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 16F 16 valve mounting stations (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 16 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 323 mm KA 313 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 323 mm KA 313 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 16F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1103.21 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M16FG

    Airtac 100M series: pneumatic valve manifold base - 100M16FG

    Specifications Specifications: 100M16FG is an AirTAC 100M manifold with 16 mounting stations and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 16F 16 valve mounting stations G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 16 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 323 mm KA 313 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 323 mm KA 313 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 16F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 1103.21 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M1F

    Airtac 100M series: pneumatic valve manifold base - 100M1F

    Specifications Specifications: 100M1F is an AirTAC 100M manifold with 1 mounting station and PT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 1F 1 valve mounting station (blank) PT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 1 Common port nominal size 1/4 in PT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 38 mm KA 28 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 38 mm KA 28 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 1F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 129.79 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (PT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; BB male–male; BD male–female; BESL adjustable silencer; BKC compression fitting; BPC metal straight; BPOC metal straight; BSL silencer; BSLM miniature silencer; GAFR upstream filter-regulator; GPSA/PSA inline flow control; PAL plastic silencer; PALM miniature plastic silencer; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PPA plug-in silencer; PSL elbow flow control; PSS flow control; PTL push-lock flow control; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008,GAFR20008S,GAFR30008S BP,BR male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,GPSA10,GPSA10D,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHF1002,PHF1002-S,PHF1002D,PHF1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PSA10,PSA10-S,PSA10D,PSA10D-S,PSL1002A,PSL1002A-S,PSL1002AD,PSL1002AD-S,PSL1002B,PSL1002B-S,PSL1002BD,PSL1002BD-S,PSS1002A,PSS1002A-S,PSS1002AD,PSS1002AD-S,PSS1002B,PSS1002B-S,PSS1002BD,PSS1002BD-S,PTL1002A,PTL1002AD,PTL1002B,PTL1002BD,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,GPSA12,GPSA12D,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PSA12,PSA12-S,PSA12D,PSA12D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,GPSA4,GPSA4D,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PSA4,PSA4-S,PSA4D,PSA4D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,GPSA6,GPSA6D,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHF602,PHF602-S,PHF602D,PHF602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PSA6,PSA6-S,PSA6D,PSA6D-S,PSL602A,PSL602A-S,PSL602AD,PSL602AD-S,PSL602B,PSL602B-S,PSL602BD,PSL602BD-S,PSS602A,PSS602A-S,PSS602AD,PSS602AD-S,PSS602B,PSS602B-S,PSS602BD,PSS602BD-S,PTL602A,PTL602AD,PTL602B,PTL602BD,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,GPSA8,GPSA8D,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHF802,PHF802-S,PHF802D,PHF802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PSA8,PSA8-S,PSA8D,PSA8D-S,PSL802A,PSL802A-S,PSL802AD,PSL802AD-S,PSL802B,PSL802B-S,PSL802BD,PSL802BD-S,PSS802A,PSS802A-S,PSS802AD,PSS802AD-S,PSS802B,PSS802B-S,PSS802BD,PSS802BD-S,PTL802A,PTL802AD,PTL802B,PTL802BD,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR BESL02,BESL02-S,BSL02,BSL02-S,BSLM02,BSLM02-S,PAL02,PAL02D,PALM02,PALM02D10: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match PT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. PHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; BB/BD/BKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are MPa/psi. PTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M1FG

    Airtac 100M series: pneumatic valve manifold base - 100M1FG

    Specifications Specifications: 100M1FG is an AirTAC 100M manifold with 1 mounting station and G threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 1F 1 valve mounting station G G thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 1 Common port nominal size 1/4 in G Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 38 mm KA 28 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 38 mm KA 28 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 1F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 129.79 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (G1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; GBB male–male; GBD male–female; GBESL adjustable silencer; GBKC compression fitting; GBPC metal straight; GBSL silencer; GBSLM miniature silencer; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPSA/PSA inline flow control; GPSS flow control; GPTL push-lock flow control; GPYB Y; GPZB cross; PPA plug-in silencer; UE PU tube; US PU tube. Use Size / complete codes BP ASC20008G,GAFR20008SG,GAFR30008SG BP,BR male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHF1002,GPHF1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPSA10,GPSA10D,GPSS1002A,GPSS1002AD,GPSS1002B,GPSS1002BD,GPTL1002A,GPTL1002AD,GPTL1002B,GPTL1002BD,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D,PSA10,PSA10-S,PSA10D,PSA10D-S12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPSA12,GPSA12D,GPYB1202,GPYB1202D,PSA12,PSA12-S,PSA12D,PSA12D-S4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPSA4,GPSA4D,GPYB402,GPYB402D,PSA4,PSA4-S,PSA4D,PSA4D-S6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHF602,GPHF602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPSA6,GPSA6D,GPSS602A,GPSS602AD,GPSS602B,GPSS602BD,GPTL602A,GPTL602AD,GPTL602B,GPTL602BD,GPYB602,GPYB602D,GPZB602,GPZB602D,PSA6,PSA6-S,PSA6D,PSA6D-S8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHF802,GPHF802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPSA8,GPSA8D,GPSS802A,GPSS802AD,GPSS802B,GPSS802BD,GPTL802A,GPTL802AD,GPTL802B,GPTL802BD,GPYB802,GPYB802D,GPZB802,GPZB802D,PSA8,PSA8-S,PSA8D,PSA8D-Smain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU BR GBESL02,GBSL02,GBSLM0210: PPA1012: PPA126: PPA68: PPA8 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match G1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. PSA/GPSA tube-side controllers need separate matching tube connections. PPA silencers need matching metric push-in exhaust sockets; they are not threaded plugs or vacuum filters. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. GPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; GBB/GBD/GBKC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including PSA/GPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are bar/MPa. GPTL recommended adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Listed PU examples are separate blue 100 m coils, rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Keep within manifold/valve/component limits and temperature derating; the 23°C pressure rating does not apply throughout the temperature range. Match OD/ID; order inch tubing separately. Catalog listing is not a stock or delivery promise.

  • 100M1FT

    Airtac 100M series: pneumatic valve manifold base - 100M1FT

    Specifications Specifications: 100M1FT is an AirTAC 100M manifold with 1 mounting station and NPT threaded common connections. It groups valves of the catalog-listed matching size on a shared manifold. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model 100M 100 series manifold 1F 1 valve mounting station T NPT thread Applicable Valve and Manifold Series Valve series Catalog-confirmed matching manifold 4V100 series 100M; explicit application table in 2022 printed page 82 5V100 series 100M; explicit application table in 2022 printed page 82 4A100 series 100M; explicit application table in the linked PDF and 2022 printed page 123 Choose the exact manifold size listed above. The reviewed application tables do not list 4M NAMUR valves for this manifold; a similar size number does not establish a compatible mounting interface. Technical Data Parameter Details Product type Directional-valve manifold Matching manifold 100M Published station range 1–16 stations Working medium for the manifold Air filtered through a 40 µm filter element Published working temperature −20 to 70 °C This model station count 1 Common port nominal size 1/4 in NPT Construction and Kit Contents Manifold kits list a manifold, manifold sealing gasket and screws. The catalog lists a manifold, manifold sealing gasket and screws as the kit components, but does not specify their individual quantities. The station-count code gives the number of valve mounting positions; it is not a screw or seal quantity. The manifold and blank-plate kit have separate ordering codes. Valves, silencers, fittings and additional blank plates are not listed among the manifold-kit components. The manifold allows valves of one matching series to form a compact group with common supply and exhaust passages. The catalog describes space savings, easier fault tracing through organized connections, and flexible combinations within the supported station-count range. Electrical wiring applies to the installed solenoid valves, not to the manifold or blank plate itself. Dimensions and Mounting The catalog dimensions below refer to the illustrated valve-and-manifold assembly. They are not measurements of a loose blank plate or a bare manifold alone. Linear values are in millimeters; P is the common threaded port. K is the mounting-hole diameter. The other lettered callouts retain the exact drawing labels. Use the drawing for the applicable valve family and arrangement. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Assembly Drawing Reference — 4A100 Parameter Details A 38 mm KA 28 mm B 96 mm BA 81 mm BC 68.7 mm BD 28 mm C 49 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm Assembly Drawing Reference — 4V100 Parameter Details A 38 mm KA 28 mm B 154.5 mm BA 142.5 mm BC 99.5 mm BD 28 mm C 77 mm CA 22 mm CB 27 mm D 57.5 mm E 43 mm F 19 mm G 19 mm H 36 mm K 4.5 mm KB 5 mm KC 20 mm P 1/4 in PA 10 mm PB 40 mm The 2022 application table also lists the matching 5V size, but its illustrated assembly here is labeled 4V. The 4V assembly envelope must not be treated as a separately verified 5V overall envelope. The A and KA values shown are the printed 1F station-count entries. Station counts above 16 are not offered in the reviewed ordering table for this manifold size. Ordering Notes The matching blank-plate kit is P-100M-R2. Manifold thread options are blank = PT, G = G thread and T = NPT. The R2 blank-plate ordering code has no thread-option suffix. A different valve size requires its separately listed manifold and blank plate. Reference Weight Estimated reference weight: 129.79 g. Calculated from this component’s documented envelope with an assumed aluminum density of 2.70 g/cm³. Internal passages and recesses are not subtracted, and seals, screws, installed valves and packaging are not separately added. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.Matching Accessory Codes and Conditions P-100M-R2 closes an unused valve mounting station on 100M; it is not a threaded port plug. Order separately. The blanking kit contains the plate and screws; quantities are not specified. Optional Connections and Air Preparation BP = this base’s common supply; BR = its marked common exhaust (NPT1/4). These are the actual thread and size of this base SKU. Keep supply and exhaust separate. Installed valves have their own working and pilot ports; neither is assigned here. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): ASC inline threaded flow control; GAFR upstream filter-regulator; NBB male–male; NBD male–female; NBESL adjustable silencer; NBKC compression fitting; NBPC metal straight; NBSL silencer; NBSLM miniature silencer; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPSA inline flow control; NPSS flow control; NPTL push-lock flow control; NPYB Y; NPZB cross. Use Size / complete codes BP ASC20008T,GAFR20008ST,GAFR30008ST BP,BR (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/4 ↔ male NPT1/8: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHF1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPSS1/4-1/4A,NPSS1/4-1/4B,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHF3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPSS3/8-1/4A,NPSS3/8-1/4B,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHF5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPSS5/16-1/4A,NPSS5/16-1/4B,NPZB5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 BR (discontinued) NBESL1/4 BR NBSL1/4,NBSLM1/4 BP,BR 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPSA1/2,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPSA1/4,NPTL1/4-1/4A,NPTL1/4-1/4B,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPSA3/8,NPTL3/8-1/4A,NPTL3/8-1/4B,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPSA5/16,NPTL5/16-1/4A,NPTL5/16-1/4B,NPYB5/16-1/4 Listed piping accessories are optional and ordered separately. BP and BR mean only this base SKU’s actual common supply and common exhaust connections, respectively. Match NPT1/4 exactly; the installed valves have their own working ports. The manifold page gives no independent bare-base pressure rating. Confirm the complete assembly limits, including the actual valve’s required minimum supply or pilot pressure and every lower maximum. Use the specified thread seal or face gasket. Match tube OD and compression OD/ID; metric and inch sizes differ. Use suitable soft nylon or polyurethane tube, with correct insertion, clearance, bends and flow capacity. For compression fittings, place the locking cap over the tube, fully insert the tube and tighten the cap. Tighten the connector thread by the body hex, not the tube nut. Where listed, D means black, blank means grey, -M means miniature, and -S identifies the specified 304 stainless parts only. NPSA tube-side controllers need separate matching tube connections. ASC and GAFR female ports need separate matching male connections. Distribution branches share the circuit. NPHF female RB matches the stated male RA thread: connect or seal as permitted; it is not a tube socket. Match both ends of an adapter independently, including the separate mating part for a reduced female end. Keep the common supply and exhaust circuits separate. Keep the manifold path within −20–70°C and every narrower installed valve/component limit. Standard push-in fittings, silencers and flow-control parts: ≤1 MPa, −20–70°C. NBB/NBD/NBKC/NBPC: ≤1 MPa. These metal fittings/adapters are rated 0–150°C, restricting this manifold path to 0–70°C or narrower. These accessory values do not establish a manifold pressure rating. No complete-system vacuum rating is established. For listed flow controllers, suffix A restricts thread-to-tube flow with free reverse flow; suffix B reverses it. Common supply normally flows tube-to-thread and common exhaust thread-to-tube. A controller on a common line affects all connected active stations, not one actuator. Follow the flow symbols, including NPSA, and actual circuit direction. Closed controls permit leakage and do not provide isolation. Open gradually from closed without forcing stops; depressurize before removing tubes. Silencers serve marked common exhaust ports only. Check the combined flow of all active stations and permitted back pressure; adjustable silencers and remote exhaust affect the shared circuit. Never cap an active supply or exhaust connection. Connect ASC separately in the common-supply circuit and follow its P/A markings: 0.05–0.95 MPa, −20–70°C, air filtered to 40 µm or finer. Put GAFR upstream of common supply and follow IN→OUT: inlet ≤1 MPa, standard regulation 0.15–0.9 MPa, −5–70°C nonfreezing. Set supply within the actual installed valve requirements and all assembly/component limits; neither accessory establishes a bare-base rating. GAFR narrows this path to −5–70°C or a narrower component limit. Select flow capacity and bowl/environment suitability. Listed GAFR S versions have a PC bowl, differential/manual drain, bracket, round snap-in gauge and 40 µm filter, without a reverse-flow valve. Both ASC and GAFR have female ports and need separately selected matching male connections. The listed GAFR gauge units are psi/bar. NPTL maximum adjusting-cap rotation torque for 1/4: 0.16 N·m. This is not thread-installation torque. Order matching inch tubing separately; do not substitute a nearby metric OD. Items marked discontinued are historical service references. Confirm remaining availability or a manufacturer-approved replacement. An unmarked catalog item is not a stock or delivery promise.