X-KCV Series Vacuum Ejector
Features
- Integrated Design: Combines a high-performance vacuum ejector with an optional mechanical pressure switch for system monitoring.
- Aluminum Body: Robust aluminum construction ensures durability in industrial environments.
- Wide Range: Nozzle diameters available from 0.5mm to 3.0mm, covering a wide range of suction flow and vacuum levels.
- Versatile Options: Available in High Vacuum (H) and Large Flow (L) types to suit different application needs.
- Pressure Switch: Optional adjustable (CK) or non-adjustable (C) pressure switches for vacuum confirmation signal.
Ejector Performance Specifications
| Model | Nozzle (mm) | Rated Pressure (MPa) | Max Vacuum (kPa) | Max Suction Flow (l/min) | Air Consumption (l/min) | ||
|---|---|---|---|---|---|---|---|
| HS / HR | LS | HS / HR | LS | ||||
| X-KCV05 | 0.5 | 0.5 | -87 | -57 | 7 | 10 | 13 |
| X-KCV10 | 1.0 | 0.5 / 0.35(HR) | -92/-91(HR) | -57 | 27 / 25(HR) | 36 | 44 |
| X-KCV15 | 1.5 | 0.5 / 0.35(HR) | -92/-91(HR) | -57 | 63 / 54(HR) | 95 | 100 |
| X-KCV20 | 2.0 | 0.5 / 0.35(HR) | -92/-91(HR) | -57 | 110 / 88(HR) | 170 | 180 |
| X-KCV25 | 2.5 | 0.5 | -92 | -57 | 160 | 250 | 265 |
| X-KCV30 | 3.0 | 0.5 | -92 | -57 | 225 | 350 | 385 |
Note: "HS" = High Vacuum / Standard Pressure; "LS" = Large Flow / Standard Pressure; "HR" = High Vacuum / Low Rated Pressure (0.35MPa).
Pressure Switch Specifications (Model CK)
| Item | Specification |
|---|---|
| Switch Model | CK (Mechanical Type) |
| Fluid | Air |
| Setting Pressure Range | -20 ~ -53 kPa |
| Ambient Temperature | 0 ~ 60 °C (No freezing) |
| Accuracy | ± 5.3 kPa |
| Differential (Hysteresis) | 4.0 ~ 13.3 kPa |
| Rated Voltage/Current |
AC 250V / 3A DC 24V / 0.2A |
Ordering Code
X-KCV 10 H S CK
| No. | Item | Options / Description |
|---|---|---|
| ① | Model | X-KCV: Basic Vacuum Ejector |
| ② | Nozzle Diameter |
05: 0.5mm 10: 1.0mm 15: 1.5mm 20: 2.0mm 25: 2.5mm 30: 3.0mm |
| ③ | Max Vacuum |
H: -87 ~ -92 kPa (High Vacuum Type) L: -53 ~ -57 kPa (Large Flow Type) |
| ④ | Rated Pressure |
S: 0.5 MPa (Standard) R: 0.35 MPa (Low Pressure - Only for 10/15/20 sizes) |
| ⑤ | Pressure Switch |
Blank: Standard (No Switch) CK: With Adjustable Pressure Switch C: With Non-Adjustable Pressure Switch |