Explosion-proof Solenoid Valve (B03 Series)
Product Features
- Design Evolution: Developed from standard solenoid valves (3V1, 3V, 4V, 4M) by replacing the standard coil with an explosion-proof coil.
- Encapsulation: The explosion-proof coil utilizes a potting encapsulation method with a sealing introduction device for enhanced safety.
- Explosion-proof Rating: Complies with Class II Explosion-proof T5 group standards. The maximum surface temperature of the coil reaches 100°C, suitable for factory industrial use.
- Safety Protection: Equipped with a built-in thermal fuse inside the coil. In the event of an external fault causing overheating, the fuse cuts off the circuit to ensure safety.
General Specifications
Valve Body & Structure
The valve body part (mechanical structure) is identical to the standard AirTAC series corresponding to the model number:
- B03-3V1 corresponds to Standard 3V1 Series.
- B03-3V corresponds to Standard 3V Series (3/2 way).
- B03-4V corresponds to Standard 4V Series (5/2, 5/3 way).
- B03-4M corresponds to Standard 4M Series (Namur standard).
Coil Electrical Specifications
| Coil Series | CFB092-A (AC) | CFB092-B (DC) | |
|---|---|---|---|
| AC220V (50Hz) | AC220V (60Hz) | DC24V | |
| Operating Temp | -15°C ~ +50°C | ||
| Heat Class | Class II Explosion-proof T5 Group (II 类防爆型T5组别) | ||
| Start Power | 4.8 VA | 4.0 VA | - |
| Holding Power | 3.2 VA | 2.7 VA | 3.0 W |
| Surface Temp Rise | 15°C | 10°C | 35°C |
| Internal Temp Rise | 30°C | 25°C | 40°C |
| Applicable Valves | 3V1, 3V200, 3V300, 4V200, 4V300, 4V400, 4M200, 4M300 | ||
Product Ordering Code
1. B03-3V200 / 300 Series (3/2 Way)
Example: B03-3V 2 10 08 NO A
| Feature | Specs | Series | Control | Port Size | Initial State | Voltage |
|---|---|---|---|---|---|---|
|
B03: Explosion-proof |
3V: 3/2 Way |
2: 200 Series 3: 300 Series |
10: Single Solenoid 20: Double Solenoid |
06: 1/8" 08: 1/4" 10: 3/8" |
NC: Normally Closed NO: Normally Open (Blank for Double Solenoid) |
A: AC220V B: DC24V |
2. B03-4V200 / 300 / 400 Series (5/2, 5/3 Way)
Example: B03-4V 2 10 08 A
| Feature | Specs | Series | Control Function | Port Size | Voltage |
|---|---|---|---|---|---|
| B03 |
4V: 5/2 or 5/3 Way |
2: 200 Series 3: 300 Series 4: 400 Series |
10: 5/2 Single Solenoid 20: 5/2 Double Solenoid 30C: 5/3 Closed Center 30E: 5/3 Exhaust Center 30P: 5/3 Pressure Center |
06: 1/8" 08: 1/4" 10: 3/8" 15: 1/2" |
A: AC220V B: DC24V |
3. B03-4M200 / 300 Series (Namur Type)
Example: B03-4M 2 10 08 A
| Feature | Specs | Series | Control | Port Size | Voltage |
|---|---|---|---|---|---|
| B03 |
4M: 5/2 Namur |
2: 200 Series 3: 300 Series |
10: Single Solenoid 20: Double Solenoid |
06: 1/8" 08: 1/4" 10: 3/8" |
A: AC220V B: DC24V |
4. B03-3V1 Series (Direct Acting 3/2 Way)
Example: B03-3V1 06 A
| Feature | Specs | Port Size | Voltage |
|---|---|---|---|
| B03 | 3V1: 3/2 Direct Acting | 06: 1/8" |
A: AC220V B: DC24V |
5. Coil Part Ordering
| Coil Type | Specs Code | Voltage |
|---|---|---|
| CFB: Explosion-proof Coil | 092 |
A: AC220V B: DC24V |