428 products

DMS/EMS/CMS Series Sensors & Accessories

DMS, EMS, CMS Series Sensors & Accessories

  • Product Features
  • Specifications
  • Accessories & Wiring
  • Ordering Code

Series Overview

  • DMS Series (Solid State): Standard electronic sensor. Features high response speed, long life, and reverse polarity protection. Available in 2-wire and 3-wire (NPN/PNP) configurations.
  • EMS Series (Solid State): Similar to DMS but designed with a higher mounting profile, making it suitable for compact cylinders where the sensor groove is deeper.
  • CMS Series (Reed Switch): Magnetic reed switch type. Supports both AC and DC voltages. Available in standard and high-temperature models (Red).

Key Features

  • Industry Application Models:
    • General Type (Blue): Standard application.
    • Waterproof Type (Yellow): IP68 rated for wet environments.
    • Mechanical Hand/High Flex (A05): Designed for robotics and drag chains, tested for high bending resistance.
    • Oil Resistant (A06): Designed for environments with cutting fluids and oil mist.
  • Robust Design: Strain relief (SR) structure at the cable exit prevents wire breakage. Made from high-impact engineering materials.
  • Versatile Mounting: Compatible with various cylinder types using F-MQ (Round/Tie-rod) or F-SC (Tie-rod) mounting brackets.

Sensor Specifications Comparison

Item DMS / EMS (2-Wire) DMS (3-Wire NPN/PNP) CMS (Reed Switch)
Sensor Type Solid State (Electronic) Reed Switch (Magnetic)
Voltage 10V ~ 28V DC 5V ~ 30V DC 5V ~ 240V AC/DC
Switching Current 2.5 ~ 100 mA 200 mA Max. 100 mA Max.
Contact Rating 2.8W Max. 6.0W Max. 10W Max.
Current Consumption 3 mA Max. @ 24V 5 mA Max. None
Voltage Drop 3.5V Max. 0.7V Max. 2.5V Max. (@100mA DC)
Leakage Current 0.06 mA Max. 0.01 mA Max. None
Frequency 1000 Hz 1000 Hz 200 Hz
Protection Polarity Reverse / Surge Polarity Reverse / Surge None
Temperature -10°C ~ 70°C -10°C ~ 70°C (High Temp: 125°C)

Mounting Accessories (Brackets)

Bracket Model Description Applicable Cylinders
F-MQ For Round Body & Tie-Rod Cylinders. Aluminum alloy or Stainless steel options. Round: MI, PB, MA, MAL (Bore 16-63)
Tie-Rod: SC, SU, SGC, TWG (Bore 32-100)
F-SC For Tie-Rod Cylinders. Aluminum alloy. SC, SGC (Bore 32-250)

Female Connectors (F-EC Series)

Used for connecting sensors with M8 or M12 plugs.

Type M8 Connector M12 Connector
Pin Configuration 3-Pin (Threaded) 4-Pin (Threaded)
Wire Colors Brown (+), Blue (-), Black (Output) Brown (+), Blue (-), Black (Output)
Available Shapes Straight Type / Right Angle Type

Sensor Ordering Code

DMS G - N - 020
Item Options
① Industry Blank: General
A05: Mechanical Hand (High Flex)
A06: Oil Resistant
② Series DMS: Solid State (Standard)
EMS: Solid State (High Mounting)
CMS: Reed Switch
③ Shape G: Groove Type (Standard)
H: Round Profile
E: Compact Profile
J: Vertical Wire Exit
④ Output Blank: 2-Wire (DMS/EMS/CMS)
N: NPN 3-Wire (DMS only)
P: PNP 3-Wire (DMS only)
⑤ Length 020: 2m | 030: 3m | 050: 5m | 100: 10m
⑥ Connector Blank: Flying Leads
M08/M12: With Connector (See connector options in catalog)
⑦ Feature Blank: Standard IP64
W: Waterproof IP68
H: High Temp (CMS only)

Accessory Ordering Code

F - MQ - 32
Item Description
Category F: Accessory
Type MQ: Multi-purpose Bracket
SC: Tie-rod Bracket
EC: Electrical Connector Cable
Spec [Bore Size]: e.g., 32, 40, 50 (for Brackets)
[M08/M12]: Connector Type (for EC cables)
  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM12B050

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM12B050

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M12 female joint Number of cores: 2-wire type Wiring length: 5m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM12B030

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM12B030

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M12 female joint Number of cores: 2-wire type Wiring length: 3m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM12B020

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM12B020

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M12 female joint Number of cores: 2-wire type Connection length: 2m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM08C050

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM08C050

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M8 female joint Number of cores: 3-wire type Wiring length: 5m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM08C030

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM08C030

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M8 female joint Number of cores: 3-wire type Wiring length: 3m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM08C020

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM08C020

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M8 female joint Number of cores: 3-wire type Connection length: 2m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM08B100

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM08B100

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M8 female joint Number of cores: 2-wire type Wiring length: 10m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM08B050

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM08B050

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M8 female joint Number of cores: 2-wire type Wiring length: 5m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM08B030

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM08B030

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M8 female joint Number of cores: 2-wire type Wiring length: 3m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: female connector at line end  - F-ECM08B020

    Airtac DMS,EMS,CMS series: female connector at line end - F-ECM08B020

    Category: Accessories (female connector at line end) Specifications: connection line Joint type: M8 female joint Number of cores: 2-wire type Connection length: 2m Click to download Airtac product catalog Product Features 1. When the sensor is installed, it must not be dropped or subjected to too much impact. 2. The sensor wire shall not move with the action of the cylinder. 3. When the sensor is installed, the clamping torque should be within the allowable range (0.15~0.2Nm). 4. The sensor should be installed in the middle of the range of action. 5. Sensor wiring: A. The wire cannot withstand repeated torsion and tension. Please connect an external load before turning on the power. B. Conductors are well insulated. C do not connect with power cord and high voltage line, and do not use 1 wiring pipe. D. Please wire correctly according to the circuit diagram. 6. Perform regular maintenance according to the following guidelines: A. Ensure that the sensor is firmly fixed. B. Make sure the wires are intact. C. Ensure that the LED correctly indicates the movement of the cylinder. 7. Use environment: A. It is not allowed to use the sensor in an explosive gas environment. B. The magnetic sensor should not be used in an external magnetic environment. C. Magnetic sensors should not be used in environments that are often eroded by water. D. The magnetic sensor should not be used in an environment with oil, moisture or chemicals. E. The magnetic sensor should not be used in an environment where the temperature changes periodically. F. The magnetic sensor should not be used in an environment with excessive impact. G. Magnetic sensors should not be used in environments where there is an electrical pulse source. H. Avoid using the sensor in an environment with accumulated iron powder and strong magnetic objects.

  • Airtac  DMS,EMS,CMS series: tie rod cylinder-accessories  - F-SC50SH

    Airtac DMS,EMS,CMS series: tie rod cylinder-accessories - F-SC50SH

    Category: Attachments Specifications: Sensor mounting accessories for tie rod cylinders Applicable cylinder diameter: ø50 Click to download Airtac product catalog Product Features

  • Airtac  CMS Series: Reed Sensors  - A05-CMSJ-100

    Airtac CMS Series: Reed Sensors - A05-CMSJ-100

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: J Wiring type: direct outgoing line: line length 10m Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSJ-050

    Airtac CMS Series: Reed Sensors - A05-CMSJ-050

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: J Wiring type: direct outgoing line: 5m long Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSJ-030

    Airtac CMS Series: Reed Sensors - A05-CMSJ-030

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: J Wiring type: direct outgoing line: 3m long Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSJ-020

    Airtac CMS Series: Reed Sensors - A05-CMSJ-020

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: J Wiring type: direct outgoing line: line length 2m Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSE-100

    Airtac CMS Series: Reed Sensors - A05-CMSE-100

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: E Wiring type: direct outgoing line: line length 10m Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSE-050

    Airtac CMS Series: Reed Sensors - A05-CMSE-050

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: E Wiring type: direct outgoing line: 5m long Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSE-030

    Airtac CMS Series: Reed Sensors - A05-CMSE-030

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: E Wiring type: direct outgoing line: 3m long Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSH-100

    Airtac CMS Series: Reed Sensors - A05-CMSH-100

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: H Wiring type: direct outgoing line: line length 10m Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSH-050

    Airtac CMS Series: Reed Sensors - A05-CMSH-050

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: H Wiring type: direct outgoing line: 5m long Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSH-030

    Airtac CMS Series: Reed Sensors - A05-CMSH-030

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: H Wiring type: direct outgoing line: 3m long Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSH-020

    Airtac CMS Series: Reed Sensors - A05-CMSH-020

    Industry: manipulator industry Series: Magnetic spring type sensor Specification: H Wiring type: direct outgoing line: line length 2m Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSG-100

    Airtac CMS Series: Reed Sensors - A05-CMSG-100

    Industry: manipulator industry Series: Magnetic spring type sensor Specifications: G Wiring type: direct outgoing line: line length 10m Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.

  • Airtac  CMS Series: Reed Sensors  - A05-CMSG-050

    Airtac CMS Series: Reed Sensors - A05-CMSG-050

    Industry: manipulator industry Series: Magnetic spring type sensor Specifications: G Wiring type: direct outgoing line: 5m long Special rules: general type Click to download Airtac product catalog Product Features 1. Anti-deflection wire, can be used in manipulator industry, such as multi-joint manipulator, tank chain. 2. In the temperature, dust, or water droplets, oil dust occasions, the sensor should take the appropriate dust measures.


You have seen 96 out of 428 products

Login

Forgot your password?

Don't have an account yet?
Create account