56 products

Regulator Product Information

Regulator

  • Product Features
  • Specifications
  • Product Ordering Code

Product Features

  1. Independent pipe-mounted regulator, can also be installed with a panel bracket.
  2. Compact structure, easy to install and use.
  3. Stable pressure regulation with good pressure characteristics.
  4. In addition to the standard type, a low-pressure type is available (maximum adjustable pressure 0.4MPa).

Specifications

Model SR200-06 SR200L-06 SR200-08 SR200L-08
Working Medium Air
Port Size [Note 1] PT1/8 PT1/4
Pressure Regulation Range Standard type: 0.05–0.9MPa (7–130psi); Low pressure type: 0.03–0.4MPa (4–57psi)
Max Operating Pressure 1.0MPa (145Psi)
Proof Pressure 1.5MPa (215Psi)
Operating Temperature Range -20–70°C
Note 1: G and NPT thread types are available.

Product Ordering Code

Position Description Options & Values
1 Model Code
  • SR: SR Series Regulator
2 Series Code
  • 200: 200 series
3 Port Size
  • 06: 1/8"
  • 08: 1/4"
4 Model Type Code
  • Blank: Standard Type
  • L: Low Pressure Type
5 Bracket Code
  • Blank: With Bracket
  • J: Without Bracket
6 Pressure Gauge Code
  • Blank: With Pressure Gauge
  • N: Without Pressure Gauge
7 Pressure Unit
  • 1: MPa
  • 2: psi
  • 3: bar
  • 4: kgf/cm² & psi
8 Thread Code [Note 1]
  • Blank: PT thread
  • G: G thread
  • T: NPT thread
Note 1: The pressure gauge dial will correspond to the selected thread type's pressure unit.
  • Airtac SR: Air Pressure Regulator - SR200082T Airtac SR: Air Pressure Regulator - SR200082T - 2

    Airtac SR series: miniature pressure regulator - SR200082T

    Specifications: SR200082T is an Airtac 200-series mini pressure regulator with NPT 1/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included psi-scale pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 NPT 1/4 main connection Blank — pressure Standard type; 0.05–0.9 MPa Blank — bracket Bracket included 2 Pressure gauge included; psi scale T NPT thread Technical Specifications Parameter Details Model SR200082T Working medium Air Main port NPT 1/4 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 2, thread T. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × NPT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s NPT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross. Use Size / complete codes IN,OUT (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/8 ↔ male NPT1/4: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPZB5/16-1/41/4 in; male RA NPT1/4 / female RB NPT1/4: NPHF1/4-1/43/8 in; male RA NPT1/4 / female RB NPT1/4: NPHF3/8-1/45/16 in; male RA NPT1/4 / female RB NPT1/4: NPHF5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 IN,OUT 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPYB5/16-1/4 These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. NPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. NBPC/compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008LJNT Airtac SR: Air Pressure Regulator - SR20008LJNT - 2

    Airtac SR series: miniature pressure regulator - SR20008LJNT

    Specifications: SR20008LJNT is an Airtac 200-series mini pressure regulator with NPT 1/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 NPT 1/4 main connection L Low-pressure type; 0.03–0.4 MPa J Without bracket N Without pressure gauge T NPT thread Technical Specifications Parameter Details Model SR20008LJNT Working medium Air Main port NPT 1/4 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type L, gauge N, thread T. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × NPT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s NPT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross. Use Size / complete codes IN,OUT (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/8 ↔ male NPT1/4: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPZB5/16-1/41/4 in; male RA NPT1/4 / female RB NPT1/4: NPHF1/4-1/43/8 in; male RA NPT1/4 / female RB NPT1/4: NPHF3/8-1/45/16 in; male RA NPT1/4 / female RB NPT1/4: NPHF5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 IN,OUT 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPYB5/16-1/4 These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. NPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. NBPC/compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008JNT Airtac SR: Air Pressure Regulator - SR20008JNT - 2

    Airtac SR series: miniature pressure regulator - SR20008JNT

    Specifications: SR20008JNT is an Airtac 200-series mini pressure regulator with NPT 1/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 NPT 1/4 main connection Blank — pressure Standard type; 0.05–0.9 MPa J Without bracket N Without pressure gauge T NPT thread Technical Specifications Parameter Details Model SR20008JNT Working medium Air Main port NPT 1/4 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type (blank), gauge N, thread T. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × NPT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s NPT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross. Use Size / complete codes IN,OUT (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/8 ↔ male NPT1/4: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPZB5/16-1/41/4 in; male RA NPT1/4 / female RB NPT1/4: NPHF1/4-1/43/8 in; male RA NPT1/4 / female RB NPT1/4: NPHF3/8-1/45/16 in; male RA NPT1/4 / female RB NPT1/4: NPHF5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 IN,OUT 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPYB5/16-1/4 These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. NPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. NBPC/compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20006N Airtac SR: Air Pressure Regulator - SR20006N - 2

    Airtac SR series: miniature pressure regulator - SR20006N

    Specifications: SR20006N is an Airtac 200-series mini pressure regulator with PT 1/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 06 PT 1/8 main connection Blank — pressure Standard type; 0.05–0.9 MPa Blank — bracket Bracket included N Without pressure gauge Blank — thread PT thread Technical Specifications Parameter Details Model SR20006N Working medium Air Main port PT 1/8 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread (blank). Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × PT 1/8 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s PT1/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male PT1/8 ↔ male PT1/8: BB0101,BB0101-Smale PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT3/8 ↔ male PT1/8: BB0103,BB0103-S4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-01,BKC0806-01-S10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S4; male RA PT1/8 / female RB PT1/8: PHF401,PHF401-S,PHF401D,PHF401D-S6; male RA PT1/8 / female RB PT1/8: PHF601,PHF601-S,PHF601D,PHF601D-S8; male RA PT1/8 / female RB PT1/8: PHF801,PHF801-S,PHF801D,PHF801D-Smain 6 / branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S10 × 6.5: UE95A100065100MBU,US98A100065100MBU12 × 8: UE95A120080100MBU,US98A120080100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. PHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20006J3G Airtac SR: Air Pressure Regulator - SR20006J3G - 2

    Airtac SR series: miniature pressure regulator - SR20006J3G

    Specifications: SR20006J3G is an Airtac 200-series mini pressure regulator with G 1/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, an included bar-scale pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 06 G 1/8 main connection Blank — pressure Standard type; 0.05–0.9 MPa J Without bracket 3 Pressure gauge included; bar scale G G thread Technical Specifications Parameter Details Model SR20006J3G Working medium Air Main port G 1/8 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge 3, thread G. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × G 1/8 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s G1/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male G1/8 ↔ male G1/8: GBB0101male G1/4 ↔ male G1/8: GBB0102male G3/8 ↔ male G1/8: GBB01034 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0110: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D12: GPC1201,GPC1201D,GPL1201,GPL1201D4; male RA G1/8 / female RB G1/8: GPHF401,GPHF401D6; male RA G1/8 / female RB G1/8: GPHF601,GPHF601D8; male RA G1/8 / female RB G1/8: GPHF801,GPHF801Dmain 6 / branch 4: GPKD6-401,GPKD6-401D10 × 6.5: UE95A100065100MBU,US98A100065100MBU12 × 8: UE95A120080100MBU,US98A120080100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. GPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR200084 Airtac SR: Air Pressure Regulator - SR200084 - 2

    Airtac SR series: miniature pressure regulator - SR200084

    Specifications: SR200084 is an Airtac 200-series mini pressure regulator with PT 1/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included kgf/cm² and psi-scale pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 PT 1/4 main connection Blank — pressure Standard type; 0.05–0.9 MPa Blank — bracket Bracket included 4 Pressure gauge included; kgf/cm² and psi scale Blank — thread PT thread Technical Specifications Parameter Details Model SR200084 Working medium Air Main port PT 1/4 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 4, thread (blank). Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × PT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s PT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S10; male RA PT1/4 / female RB PT1/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S6; male RA PT1/4 / female RB PT1/4: PHF602,PHF602-S,PHF602D,PHF602D-S8; male RA PT1/4 / female RB PT1/4: PHF802,PHF802-S,PHF802D,PHF802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. PHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR200081 Airtac SR: Air Pressure Regulator - SR200081 - 2

    Airtac SR series: miniature pressure regulator - SR200081

    Specifications: SR200081 is an Airtac 200-series mini pressure regulator with PT 1/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included MPa-scale pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 PT 1/4 main connection Blank — pressure Standard type; 0.05–0.9 MPa Blank — bracket Bracket included 1 Pressure gauge included; MPa scale Blank — thread PT thread Technical Specifications Parameter Details Model SR200081 Working medium Air Main port PT 1/4 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 1, thread (blank). Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × PT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s PT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S10; male RA PT1/4 / female RB PT1/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S6; male RA PT1/4 / female RB PT1/4: PHF602,PHF602-S,PHF602D,PHF602D-S8; male RA PT1/4 / female RB PT1/4: PHF802,PHF802-S,PHF802D,PHF802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. PHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008LJNG

    Airtac SR series: miniature pressure regulator - SR20008LJNG

    Specifications: SR20008LJNG is an Airtac 200-series mini pressure regulator with G 1/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 G 1/4 main connection L Low-pressure type; 0.03–0.4 MPa J Without bracket N Without pressure gauge G G thread Technical Specifications Parameter Details Model SR20008LJNG Working medium Air Main port G 1/4 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type L, gauge N, thread G. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × G 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s G1/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D10; male RA G1/4 / female RB G1/4: GPHF1002,GPHF1002D6; male RA G1/4 / female RB G1/4: GPHF602,GPHF602D8; male RA G1/4 / female RB G1/4: GPHF802,GPHF802Dmain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. GPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008LJN

    Airtac SR series: miniature pressure regulator - SR20008LJN

    Specifications: SR20008LJN is an Airtac 200-series mini pressure regulator with PT 1/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 PT 1/4 main connection L Low-pressure type; 0.03–0.4 MPa J Without bracket N Without pressure gauge Blank — thread PT thread Technical Specifications Parameter Details Model SR20008LJN Working medium Air Main port PT 1/4 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type L, gauge N, thread (blank). Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × PT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s PT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S10; male RA PT1/4 / female RB PT1/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S6; male RA PT1/4 / female RB PT1/4: PHF602,PHF602-S,PHF602D,PHF602D-S8; male RA PT1/4 / female RB PT1/4: PHF802,PHF802-S,PHF802D,PHF802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. PHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008JNG

    Airtac SR series: miniature pressure regulator - SR20008JNG

    Specifications: SR20008JNG is an Airtac 200-series mini pressure regulator with G 1/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 G 1/4 main connection Blank — pressure Standard type; 0.05–0.9 MPa J Without bracket N Without pressure gauge G G thread Technical Specifications Parameter Details Model SR20008JNG Working medium Air Main port G 1/4 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type (blank), gauge N, thread G. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × G 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s G1/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D10; male RA G1/4 / female RB G1/4: GPHF1002,GPHF1002D6; male RA G1/4 / female RB G1/4: GPHF602,GPHF602D8; male RA G1/4 / female RB G1/4: GPHF802,GPHF802Dmain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. GPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008JN

    Airtac SR series: miniature pressure regulator - SR20008JN

    Specifications: SR20008JN is an Airtac 200-series mini pressure regulator with PT 1/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 PT 1/4 main connection Blank — pressure Standard type; 0.05–0.9 MPa J Without bracket N Without pressure gauge Blank — thread PT thread Technical Specifications Parameter Details Model SR20008JN Working medium Air Main port PT 1/4 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type (blank), gauge N, thread (blank). Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × PT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s PT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S10; male RA PT1/4 / female RB PT1/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S6; male RA PT1/4 / female RB PT1/4: PHF602,PHF602-S,PHF602D,PHF602D-S8; male RA PT1/4 / female RB PT1/4: PHF802,PHF802-S,PHF802D,PHF802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. PHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20006LJNT

    Airtac SR series: miniature pressure regulator - SR20006LJNT

    Specifications: SR20006LJNT is an Airtac 200-series mini pressure regulator with NPT 1/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 06 NPT 1/8 main connection L Low-pressure type; 0.03–0.4 MPa J Without bracket N Without pressure gauge T NPT thread Technical Specifications Parameter Details Model SR20006LJNT Working medium Air Main port NPT 1/8 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type L, gauge N, thread T. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × NPT 1/8 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s NPT1/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube. Use Size / complete codes IN,OUT (discontinued) male NPT1/8 ↔ male NPT1/4: NBB1/8-1/4male NPT1/8 ↔ male NPT1/8: NBB1/8-1/8male NPT1/8 ↔ male NPT3/8: NBB1/8-3/81/4 × 5/32 in: NBKC1/4-5/32-1/85/16 × 1/5 in: NBKC5/16-1/5-1/85/32 × 3/32 in: NBKC5/32-3/32-1/81/4 in: NBPC1/4-1/8,NPH1/4-1/8,NPHW1/4-1/8,NPLL1/4-1/8,NPZB1/4-1/83/8 in: NBPC3/8-1/8,NPLL3/8-1/85/16 in: NBPC5/16-1/8,NPH5/16-1/8,NPHW5/16-1/8,NPLL5/16-1/8,NPZB5/16-1/85/32 in: NBPC5/32-1/8,NPH5/32-1/8,NPHW5/32-1/8,NPLL5/32-1/81/4 in; male RA NPT1/8 / female RB NPT1/8: NPHF1/4-1/85/16 in; male RA NPT1/8 / female RB NPT1/8: NPHF5/16-1/85/32 in; male RA NPT1/8 / female RB NPT1/8: NPHF5/32-1/8main 1/4 / branches 5/32 in: NPKD1/4-5/32-1/8 IN,OUT 1/4 in: NPC1/4-1/8,NPEB1/4-1/8,NPED1/4-1/8,NPL1/4-1/8,NPYB1/4-1/83/8 in: NPC3/8-1/8,NPEB3/8-1/8,NPED3/8-1/8,NPL3/8-1/8,NPYB3/8-1/85/16 in: NPC5/16-1/8,NPEB5/16-1/8,NPED5/16-1/8,NPL5/16-1/8,NPYB5/16-1/85/32 in: NPC5/32-1/8,NPEB5/32-1/8,NPED5/32-1/8,NPL5/32-1/8,NPYB5/32-1/85/32 × 3/32 in: NUE95A5/32X3/32-100BK,NUE95A5/32X3/32-100BR,NUE95A5/32X3/32-100BU,NUE95A5/32X3/32-100C,NUE95A5/32X3/32-100CB,NUE95A5/32X3/32-100CE,NUE95A5/32X3/32-100CG,NUE95A5/32X3/32-100CR,NUE95A5/32X3/32-100CY,NUE95A5/32X3/32-100GA,NUE95A5/32X3/32-100GE,NUE95A5/32X3/32-100GN,NUE95A5/32X3/32-100R,NUE95A5/32X3/32-100WH,NUE95A5/32X3/32-100Y,NUE95A5/32X3/32-250BK,NUE95A5/32X3/32-250BR,NUE95A5/32X3/32-250BU,NUE95A5/32X3/32-250C,NUE95A5/32X3/32-250CB,NUE95A5/32X3/32-250CE,NUE95A5/32X3/32-250CG,NUE95A5/32X3/32-250CR,NUE95A5/32X3/32-250CY,NUE95A5/32X3/32-250GA,NUE95A5/32X3/32-250GE,NUE95A5/32X3/32-250GN,NUE95A5/32X3/32-250R,NUE95A5/32X3/32-250WH,NUE95A5/32X3/32-250Y,NUE95A5/32X3/32-500BK,NUE95A5/32X3/32-500BR,NUE95A5/32X3/32-500BU,NUE95A5/32X3/32-500C,NUE95A5/32X3/32-500CB,NUE95A5/32X3/32-500CE,NUE95A5/32X3/32-500CG,NUE95A5/32X3/32-500CR,NUE95A5/32X3/32-500CY,NUE95A5/32X3/32-500GA,NUE95A5/32X3/32-500GE,NUE95A5/32X3/32-500GN,NUE95A5/32X3/32-500R,NUE95A5/32X3/32-500WH,NUE95A5/32X3/32-500Y These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. NPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. NBPC/compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. NBKC5/32-3/32-1/8 specifies 3/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube. The listed NUE95A tubes serve IN and OUT only through a listed exact 5/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5/32-3/32-1/8, the supplier must also confirm 3/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1/8 in OD tube. These tubes are assigned only to the main air lines. NUE95A5/32X3/32 is ether-based PU, Shore A95±2, with 5/32 in OD × 3/32 in ID and 1/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit. In NUE codes, 100/250/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20006LJNG

    Airtac SR series: miniature pressure regulator - SR20006LJNG

    Specifications: SR20006LJNG is an Airtac 200-series mini pressure regulator with G 1/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 06 G 1/8 main connection L Low-pressure type; 0.03–0.4 MPa J Without bracket N Without pressure gauge G G thread Technical Specifications Parameter Details Model SR20006LJNG Working medium Air Main port G 1/8 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type L, gauge N, thread G. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × G 1/8 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s G1/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male G1/8 ↔ male G1/8: GBB0101male G1/4 ↔ male G1/8: GBB0102male G3/8 ↔ male G1/8: GBB01034 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0110: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D12: GPC1201,GPC1201D,GPL1201,GPL1201D4; male RA G1/8 / female RB G1/8: GPHF401,GPHF401D6; male RA G1/8 / female RB G1/8: GPHF601,GPHF601D8; male RA G1/8 / female RB G1/8: GPHF801,GPHF801Dmain 6 / branch 4: GPKD6-401,GPKD6-401D10 × 6.5: UE95A100065100MBU,US98A100065100MBU12 × 8: UE95A120080100MBU,US98A120080100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. GPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20006LJN

    Airtac SR series: miniature pressure regulator - SR20006LJN

    Specifications: SR20006LJN is an Airtac 200-series mini pressure regulator with PT 1/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 06 PT 1/8 main connection L Low-pressure type; 0.03–0.4 MPa J Without bracket N Without pressure gauge Blank — thread PT thread Technical Specifications Parameter Details Model SR20006LJN Working medium Air Main port PT 1/8 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type L, gauge N, thread (blank). Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × PT 1/8 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s PT1/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male PT1/8 ↔ male PT1/8: BB0101,BB0101-Smale PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT3/8 ↔ male PT1/8: BB0103,BB0103-S4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-01,BKC0806-01-S10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S4; male RA PT1/8 / female RB PT1/8: PHF401,PHF401-S,PHF401D,PHF401D-S6; male RA PT1/8 / female RB PT1/8: PHF601,PHF601-S,PHF601D,PHF601D-S8; male RA PT1/8 / female RB PT1/8: PHF801,PHF801-S,PHF801D,PHF801D-Smain 6 / branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S10 × 6.5: UE95A100065100MBU,US98A100065100MBU12 × 8: UE95A120080100MBU,US98A120080100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. PHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20006JNT

    Airtac SR series: miniature pressure regulator - SR20006JNT

    Specifications: SR20006JNT is an Airtac 200-series mini pressure regulator with NPT 1/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 06 NPT 1/8 main connection Blank — pressure Standard type; 0.05–0.9 MPa J Without bracket N Without pressure gauge T NPT thread Technical Specifications Parameter Details Model SR20006JNT Working medium Air Main port NPT 1/8 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge N, thread T. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × NPT 1/8 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s NPT1/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube. Use Size / complete codes IN,OUT (discontinued) male NPT1/8 ↔ male NPT1/4: NBB1/8-1/4male NPT1/8 ↔ male NPT1/8: NBB1/8-1/8male NPT1/8 ↔ male NPT3/8: NBB1/8-3/81/4 × 5/32 in: NBKC1/4-5/32-1/85/16 × 1/5 in: NBKC5/16-1/5-1/85/32 × 3/32 in: NBKC5/32-3/32-1/81/4 in: NBPC1/4-1/8,NPH1/4-1/8,NPHW1/4-1/8,NPLL1/4-1/8,NPZB1/4-1/83/8 in: NBPC3/8-1/8,NPLL3/8-1/85/16 in: NBPC5/16-1/8,NPH5/16-1/8,NPHW5/16-1/8,NPLL5/16-1/8,NPZB5/16-1/85/32 in: NBPC5/32-1/8,NPH5/32-1/8,NPHW5/32-1/8,NPLL5/32-1/81/4 in; male RA NPT1/8 / female RB NPT1/8: NPHF1/4-1/85/16 in; male RA NPT1/8 / female RB NPT1/8: NPHF5/16-1/85/32 in; male RA NPT1/8 / female RB NPT1/8: NPHF5/32-1/8main 1/4 / branches 5/32 in: NPKD1/4-5/32-1/8 IN,OUT 1/4 in: NPC1/4-1/8,NPEB1/4-1/8,NPED1/4-1/8,NPL1/4-1/8,NPYB1/4-1/83/8 in: NPC3/8-1/8,NPEB3/8-1/8,NPED3/8-1/8,NPL3/8-1/8,NPYB3/8-1/85/16 in: NPC5/16-1/8,NPEB5/16-1/8,NPED5/16-1/8,NPL5/16-1/8,NPYB5/16-1/85/32 in: NPC5/32-1/8,NPEB5/32-1/8,NPED5/32-1/8,NPL5/32-1/8,NPYB5/32-1/85/32 × 3/32 in: NUE95A5/32X3/32-100BK,NUE95A5/32X3/32-100BR,NUE95A5/32X3/32-100BU,NUE95A5/32X3/32-100C,NUE95A5/32X3/32-100CB,NUE95A5/32X3/32-100CE,NUE95A5/32X3/32-100CG,NUE95A5/32X3/32-100CR,NUE95A5/32X3/32-100CY,NUE95A5/32X3/32-100GA,NUE95A5/32X3/32-100GE,NUE95A5/32X3/32-100GN,NUE95A5/32X3/32-100R,NUE95A5/32X3/32-100WH,NUE95A5/32X3/32-100Y,NUE95A5/32X3/32-250BK,NUE95A5/32X3/32-250BR,NUE95A5/32X3/32-250BU,NUE95A5/32X3/32-250C,NUE95A5/32X3/32-250CB,NUE95A5/32X3/32-250CE,NUE95A5/32X3/32-250CG,NUE95A5/32X3/32-250CR,NUE95A5/32X3/32-250CY,NUE95A5/32X3/32-250GA,NUE95A5/32X3/32-250GE,NUE95A5/32X3/32-250GN,NUE95A5/32X3/32-250R,NUE95A5/32X3/32-250WH,NUE95A5/32X3/32-250Y,NUE95A5/32X3/32-500BK,NUE95A5/32X3/32-500BR,NUE95A5/32X3/32-500BU,NUE95A5/32X3/32-500C,NUE95A5/32X3/32-500CB,NUE95A5/32X3/32-500CE,NUE95A5/32X3/32-500CG,NUE95A5/32X3/32-500CR,NUE95A5/32X3/32-500CY,NUE95A5/32X3/32-500GA,NUE95A5/32X3/32-500GE,NUE95A5/32X3/32-500GN,NUE95A5/32X3/32-500R,NUE95A5/32X3/32-500WH,NUE95A5/32X3/32-500Y These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. NPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. NBPC/compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. NBKC5/32-3/32-1/8 specifies 3/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube. The listed NUE95A tubes serve IN and OUT only through a listed exact 5/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5/32-3/32-1/8, the supplier must also confirm 3/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1/8 in OD tube. These tubes are assigned only to the main air lines. NUE95A5/32X3/32 is ether-based PU, Shore A95±2, with 5/32 in OD × 3/32 in ID and 1/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit. In NUE codes, 100/250/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20006JNG

    Airtac SR series: miniature pressure regulator - SR20006JNG

    Specifications: SR20006JNG is an Airtac 200-series mini pressure regulator with G 1/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 06 G 1/8 main connection Blank — pressure Standard type; 0.05–0.9 MPa J Without bracket N Without pressure gauge G G thread Technical Specifications Parameter Details Model SR20006JNG Working medium Air Main port G 1/8 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge N, thread G. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × G 1/8 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s G1/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male G1/8 ↔ male G1/8: GBB0101male G1/4 ↔ male G1/8: GBB0102male G3/8 ↔ male G1/8: GBB01034 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0110: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D12: GPC1201,GPC1201D,GPL1201,GPL1201D4; male RA G1/8 / female RB G1/8: GPHF401,GPHF401D6; male RA G1/8 / female RB G1/8: GPHF601,GPHF601D8; male RA G1/8 / female RB G1/8: GPHF801,GPHF801Dmain 6 / branch 4: GPKD6-401,GPKD6-401D10 × 6.5: UE95A100065100MBU,US98A100065100MBU12 × 8: UE95A120080100MBU,US98A120080100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. GPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20006JN Airtac SR: Air Pressure Regulator - SR20006JN - 2

    Airtac SR series: miniature pressure regulator - SR20006JN

    Specifications: SR20006JN is an Airtac 200-series mini pressure regulator with PT 1/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 06 PT 1/8 main connection Blank — pressure Standard type; 0.05–0.9 MPa J Without bracket N Without pressure gauge Blank — thread PT thread Technical Specifications Parameter Details Model SR20006JN Working medium Air Main port PT 1/8 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge N, thread (blank). Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × PT 1/8 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Omitted by J; do not count a bracket as included Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s PT1/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male PT1/8 ↔ male PT1/8: BB0101,BB0101-Smale PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT3/8 ↔ male PT1/8: BB0103,BB0103-S4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-01,BKC0806-01-S10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S4; male RA PT1/8 / female RB PT1/8: PHF401,PHF401-S,PHF401D,PHF401D-S6; male RA PT1/8 / female RB PT1/8: PHF601,PHF601-S,PHF601D,PHF601D-S8; male RA PT1/8 / female RB PT1/8: PHF801,PHF801-S,PHF801D,PHF801D-Smain 6 / branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S10 × 6.5: UE95A100065100MBU,US98A100065100MBU12 × 8: UE95A120080100MBU,US98A120080100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. PHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008LNT

    Airtac SR series: miniature pressure regulator - SR20008LNT

    Specifications: SR20008LNT is an Airtac 200-series mini pressure regulator with NPT 1/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 NPT 1/4 main connection L Low-pressure type; 0.03–0.4 MPa Blank — bracket Bracket included N Without pressure gauge T NPT thread Technical Specifications Parameter Details Model SR20008LNT Working medium Air Main port NPT 1/4 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread T. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × NPT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s NPT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross. Use Size / complete codes IN,OUT (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/8 ↔ male NPT1/4: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPZB5/16-1/41/4 in; male RA NPT1/4 / female RB NPT1/4: NPHF1/4-1/43/8 in; male RA NPT1/4 / female RB NPT1/4: NPHF3/8-1/45/16 in; male RA NPT1/4 / female RB NPT1/4: NPHF5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 IN,OUT 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPYB5/16-1/4 These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. NPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. NBPC/compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008LNG

    Airtac SR series: miniature pressure regulator - SR20008LNG

    Specifications: SR20008LNG is an Airtac 200-series mini pressure regulator with G 1/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 G 1/4 main connection L Low-pressure type; 0.03–0.4 MPa Blank — bracket Bracket included N Without pressure gauge G G thread Technical Specifications Parameter Details Model SR20008LNG Working medium Air Main port G 1/4 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread G. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × G 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s G1/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D10; male RA G1/4 / female RB G1/4: GPHF1002,GPHF1002D6; male RA G1/4 / female RB G1/4: GPHF602,GPHF602D8; male RA G1/4 / female RB G1/4: GPHF802,GPHF802Dmain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. GPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008LN

    Airtac SR series: miniature pressure regulator - SR20008LN

    Specifications: SR20008LN is an Airtac 200-series mini pressure regulator with PT 1/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 PT 1/4 main connection L Low-pressure type; 0.03–0.4 MPa Blank — bracket Bracket included N Without pressure gauge Blank — thread PT thread Technical Specifications Parameter Details Model SR20008LN Working medium Air Main port PT 1/4 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread (blank). Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × PT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s PT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S10; male RA PT1/4 / female RB PT1/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S6; male RA PT1/4 / female RB PT1/4: PHF602,PHF602-S,PHF602D,PHF602D-S8; male RA PT1/4 / female RB PT1/4: PHF802,PHF802-S,PHF802D,PHF802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. PHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008NT

    Airtac SR series: miniature pressure regulator - SR20008NT

    Specifications: SR20008NT is an Airtac 200-series mini pressure regulator with NPT 1/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 NPT 1/4 main connection Blank — pressure Standard type; 0.05–0.9 MPa Blank — bracket Bracket included N Without pressure gauge T NPT thread Technical Specifications Parameter Details Model SR20008NT Working medium Air Main port NPT 1/4 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread T. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × NPT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s NPT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross. Use Size / complete codes IN,OUT (discontinued) male NPT1/2 ↔ male NPT1/4: NBB1/4-1/2male NPT1/4 ↔ male NPT1/4: NBB1/4-1/4male NPT3/8 ↔ male NPT1/4: NBB1/4-3/8male NPT1/8 ↔ male NPT1/4: NBB1/8-1/4male NPT1/4 ↔ female NPT1/8: NBD1/8-1/41/2 × 1/3 in: NBKC1/2-1/3-1/41/4 × 5/32 in: NBKC1/4-5/32-1/43/8 × 1/4 in: NBKC3/8-1/4-1/45/16 × 1/5 in: NBKC5/16-1/5-1/41/2 in: NBPC1/2-1/4,NPLL1/2-1/41/4 in: NBPC1/4-1/4,NPH1/4-1/4,NPHW1/4-1/4,NPLL1/4-1/4,NPZB1/4-1/43/8 in: NBPC3/8-1/4,NPH3/8-1/4,NPHW3/8-1/4,NPLL3/8-1/4,NPZB3/8-1/45/16 in: NBPC5/16-1/4,NPH5/16-1/4,NPHW5/16-1/4,NPLL5/16-1/4,NPZB5/16-1/41/4 in; male RA NPT1/4 / female RB NPT1/4: NPHF1/4-1/43/8 in; male RA NPT1/4 / female RB NPT1/4: NPHF3/8-1/45/16 in; male RA NPT1/4 / female RB NPT1/4: NPHF5/16-1/4main 5/16 / branch 1/4 in: NPKD5/16-1/4-1/4 IN,OUT 1/2 in: NPC1/2-1/4,NPEB1/2-1/4,NPED1/2-1/4,NPL1/2-1/4,NPYB1/2-1/41/4 in: NPC1/4-1/4,NPEB1/4-1/4,NPED1/4-1/4,NPL1/4-1/4,NPYB1/4-1/43/8 in: NPC3/8-1/4,NPEB3/8-1/4,NPED3/8-1/4,NPL3/8-1/4,NPYB3/8-1/45/16 in: NPC5/16-1/4,NPEB5/16-1/4,NPED5/16-1/4,NPL5/16-1/4,NPYB5/16-1/4 These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. NPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. NBPC/compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008NG

    Airtac SR series: miniature pressure regulator - SR20008NG

    Specifications: SR20008NG is an Airtac 200-series mini pressure regulator with G 1/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 G 1/4 main connection Blank — pressure Standard type; 0.05–0.9 MPa Blank — bracket Bracket included N Without pressure gauge G G thread Technical Specifications Parameter Details Model SR20008NG Working medium Air Main port G 1/4 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread G. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × G 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s G1/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male G1/4 ↔ male G1/8: GBB0102male G1/4 ↔ male G1/4: GBB0202male G3/8 ↔ male G1/4: GBB0203male G1/2 ↔ male G1/4: GBB0204male G1/4 ↔ female G1/8: GBD01026 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: GBKC0806-0210 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: GBKC1075-0212 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: GBKC1209-0210: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D10; male RA G1/4 / female RB G1/4: GPHF1002,GPHF1002D6; male RA G1/4 / female RB G1/4: GPHF602,GPHF602D8; male RA G1/4 / female RB G1/4: GPHF802,GPHF802Dmain 8 / branch 6: GPKD8-602,GPKD8-602D4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. GPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20008N

    Airtac SR series: miniature pressure regulator - SR20008N

    Specifications: SR20008N is an Airtac 200-series mini pressure regulator with PT 1/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 08 PT 1/4 main connection Blank — pressure Standard type; 0.05–0.9 MPa Blank — bracket Bracket included N Without pressure gauge Blank — thread PT thread Technical Specifications Parameter Details Model SR20008N Working medium Air Main port PT 1/4 Pressure regulation range 0.05–0.9 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread (blank). Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × PT 1/4 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s PT1/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube. Use Size / complete codes IN,OUT male PT1/4 ↔ male PT1/8: BB0102,BB0102-Smale PT1/4 ↔ male PT1/4: BB0202,BB0202-Smale PT3/8 ↔ male PT1/4: BB0203,BB0203-Smale PT1/2 ↔ male PT1/4: BB0204,BB0204-Smale PT1/4 ↔ female PT1/8: BD0102,BD0102-S6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU8 × 5.5 or 6: BKC0806-02,BKC0806-02-S10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU10 × 7.5 or 8: BKC1075-02,BKC1075-02-S12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU12 × 9 or 10: BKC1209-02,BKC1209-02-S10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S10; male RA PT1/4 / female RB PT1/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S6; male RA PT1/4 / female RB PT1/4: PHF602,PHF602-S,PHF602D,PHF602D-S8; male RA PT1/4 / female RB PT1/4: PHF802,PHF802-S,PHF802D,PHF802D-Smain 8 / branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S4 × 2.5: UE95A040025100MBU,US98A040025100MBU These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. PHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC/BPOC: ≤0.9 MPa; compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. US98A/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.

  • Airtac SR: Air Pressure Regulator - SR20006LNT

    Airtac SR series: miniature pressure regulator - SR20006LNT

    Specifications: SR20006LNT is an Airtac 200-series mini pressure regulator with NPT 1/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge. Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning for this model SR mini pressure regulator 200 200 size series 06 NPT 1/8 main connection L Low-pressure type; 0.03–0.4 MPa Blank — bracket Bracket included N Without pressure gauge T NPT thread Technical Specifications Parameter Details Model SR20006LNT Working medium Air Main port NPT 1/8 Pressure regulation range 0.03–0.4 MPa Maximum operating pressure 1.0 MPa Proof pressure 1.5 MPa Operating temperature −20–70 °C Weight Reference Parameter Details Reference weight 169 g; 2022 Chinese comprehensive catalog, printed page 300 / PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread T. Actual supplied-product weight may differ. Features and Operation This compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa. External and Mounting Dimensions Dimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected. Parameter Details Front width 50 mm Mounting hole pitch 34 mm Front local callout 2 mm Slot width 5.5 mm Front local vertical callout 40 mm Port-axis callout 26 mm Lower local callout 10 mm Locked-height callout 74.5 mm Knob diameter Ø28 mm Panel mounting thread M30×1.5 Bracket thickness 2 mm Body depth 38 mm Side local callout 30 mm Gauge projection reference (51.5) mm Gauge diameter Ø42 mm Gauge taps 2 × 1/8 Main ports 2 × NPT 1/8 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Accessories and Installation Parameter Details Mounting bracket Included with this model Flow / Performance Characteristics Parameter Details Chart specimen SR20006; the 08 port is not separately plotted Pressure-chart horizontal axis Inlet pressure, 0–1.0 MPa Pressure-chart vertical axis Outlet pressure, 0.18–0.22 MPa Flow horizontal axis Air flow, 0–1000 L/min; 200 L/min labels Flow vertical axis Outlet pressure, 0–0.6 MPa Flow condition Inlet pressure 0.7 MPa These values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships. Series Ordering Options The following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model. Parameter Details Main-port choices 06: 1/8; 08: 1/4 Pressure options Blank: 0.05–0.9 MPa; L: 0.03–0.4 MPa Bracket Blank: included; J: omitted Gauge N: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf/cm² and psi Thread Blank: PT; G: G; T: NPT Scale / thread combination 1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G Optional Piping Accessories IN = the SR regulator’s NPT1/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression/tubing show OD × ID. These piping accessories are optional and ordered separately. Code-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube. Use Size / complete codes IN,OUT (discontinued) male NPT1/8 ↔ male NPT1/4: NBB1/8-1/4male NPT1/8 ↔ male NPT1/8: NBB1/8-1/8male NPT1/8 ↔ male NPT3/8: NBB1/8-3/81/4 × 5/32 in: NBKC1/4-5/32-1/85/16 × 1/5 in: NBKC5/16-1/5-1/85/32 × 3/32 in: NBKC5/32-3/32-1/81/4 in: NBPC1/4-1/8,NPH1/4-1/8,NPHW1/4-1/8,NPLL1/4-1/8,NPZB1/4-1/83/8 in: NBPC3/8-1/8,NPLL3/8-1/85/16 in: NBPC5/16-1/8,NPH5/16-1/8,NPHW5/16-1/8,NPLL5/16-1/8,NPZB5/16-1/85/32 in: NBPC5/32-1/8,NPH5/32-1/8,NPHW5/32-1/8,NPLL5/32-1/81/4 in; male RA NPT1/8 / female RB NPT1/8: NPHF1/4-1/85/16 in; male RA NPT1/8 / female RB NPT1/8: NPHF5/16-1/85/32 in; male RA NPT1/8 / female RB NPT1/8: NPHF5/32-1/8main 1/4 / branches 5/32 in: NPKD1/4-5/32-1/8 IN,OUT 1/4 in: NPC1/4-1/8,NPEB1/4-1/8,NPED1/4-1/8,NPL1/4-1/8,NPYB1/4-1/83/8 in: NPC3/8-1/8,NPEB3/8-1/8,NPED3/8-1/8,NPL3/8-1/8,NPYB3/8-1/85/16 in: NPC5/16-1/8,NPEB5/16-1/8,NPED5/16-1/8,NPL5/16-1/8,NPYB5/16-1/85/32 in: NPC5/32-1/8,NPEB5/32-1/8,NPED5/32-1/8,NPL5/32-1/8,NPYB5/32-1/85/32 × 3/32 in: NUE95A5/32X3/32-100BK,NUE95A5/32X3/32-100BR,NUE95A5/32X3/32-100BU,NUE95A5/32X3/32-100C,NUE95A5/32X3/32-100CB,NUE95A5/32X3/32-100CE,NUE95A5/32X3/32-100CG,NUE95A5/32X3/32-100CR,NUE95A5/32X3/32-100CY,NUE95A5/32X3/32-100GA,NUE95A5/32X3/32-100GE,NUE95A5/32X3/32-100GN,NUE95A5/32X3/32-100R,NUE95A5/32X3/32-100WH,NUE95A5/32X3/32-100Y,NUE95A5/32X3/32-250BK,NUE95A5/32X3/32-250BR,NUE95A5/32X3/32-250BU,NUE95A5/32X3/32-250C,NUE95A5/32X3/32-250CB,NUE95A5/32X3/32-250CE,NUE95A5/32X3/32-250CG,NUE95A5/32X3/32-250CR,NUE95A5/32X3/32-250CY,NUE95A5/32X3/32-250GA,NUE95A5/32X3/32-250GE,NUE95A5/32X3/32-250GN,NUE95A5/32X3/32-250R,NUE95A5/32X3/32-250WH,NUE95A5/32X3/32-250Y,NUE95A5/32X3/32-500BK,NUE95A5/32X3/32-500BR,NUE95A5/32X3/32-500BU,NUE95A5/32X3/32-500C,NUE95A5/32X3/32-500CB,NUE95A5/32X3/32-500CE,NUE95A5/32X3/32-500CG,NUE95A5/32X3/32-500CR,NUE95A5/32X3/32-500CY,NUE95A5/32X3/32-500GA,NUE95A5/32X3/32-500GE,NUE95A5/32X3/32-500GN,NUE95A5/32X3/32-500R,NUE95A5/32X3/32-500WH,NUE95A5/32X3/32-500Y These optional connections and tubes are ordered separately for the SR regulator. Match PT/G/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features. Match tube OD and compression OD/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts. NPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection. The regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa. Use within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories. Confirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1/4 in 08 port is not separately plotted. Its 1000 L/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity. Standard push-in fittings: ≤1 MPa, −20–70°C. NBPC/compression fittings/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant. NBKC5/32-3/32-1/8 specifies 3/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube. The listed NUE95A tubes serve IN and OUT only through a listed exact 5/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5/32-3/32-1/8, the supplier must also confirm 3/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1/8 in OD tube. These tubes are assigned only to the main air lines. NUE95A5/32X3/32 is ether-based PU, Shore A95±2, with 5/32 in OD × 3/32 in ID and 1/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit. In NUE codes, 100/250/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering. When J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf/cm²/psi scales respectively, with PT main threads; code 2 selects psi with T/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature. Items marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.