Specifications: CDA116FH is an AirTAC 116-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A116 identifies an 11.6 mm coil bore; F selects DC12V; H selects Class H. The legacy ordering code has no separate normally-open K field. This exact order is listed for 2L, 2KL; applicable size groups and connection conditions are listed below.

Product Catalogs and Comparison Guide

Download Airtac Coil and Accessories Catalog (PDF)

Download Airtac 2KL Product Catalog (PDF)

Download Airtac 2KLA Product Catalog (PDF)

For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide

The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement.

Applicable Valve Series and Ordering Check

Applicable valve series for CDA116FH: 2L, 2KL. Only the model groups in the table below are listed for this exact coil selection. The coil has an 11.6 mm bore, terminal / DIN entry, DC12V supply and Class H insulation. Match all four conditions to the valve and existing coil.

Valve series and normal state Applicable valve model groups
2L — normally closed (NC) 2L030, 2L150, 2L200, 2L250 model groups.
2KL — normally open (NO) 2KL030, 2KL150, 2KL200, 2KL250 model groups.

The legacy 116/170 coil ordering code has no K position. The catalog lists the normally-closed and normally-open valve groups separately, as shown above, and separates their electrical ratings where applicable. Follow the matching NC or NO rating and the actual coil nameplate.

The final H selects Class H. The application list follows the legacy "Coil and accessories" selection table on printed page 205; it does not extend this coil to newer A-series valves.

These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range.

Ordering check: order CDA116FH for the listed valve groups when DC12V, terminal / DIN entry, an 11.6 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement.

The legacy hookup table identifies PL2925 as the connector type for this CDA116 terminal-coil family. The connector and coil have separate ordering codes; the catalog does not establish a sales-package contents list.

A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution.

Component Identity and Ordering

Parameter Details
Product type Separately ordered solenoid coil
Current ordering code CDA116FH
Coil-bore code A116 — 11.6 mm bore
Electrical entry CD — terminal / DIN
Voltage F — DC12V
Valve-type position NC/NO use selected by the valve application; the old coil code has no K position
Insulation suffix H — Class H
Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class.

Coil Electrical Data

Parameter Details
Voltage tolerance ±10%
Frequency DC; not applicable
Insulation class for this order H
Power consumption, NC or NO application 6.5 W
Temperature rise, NC or NO application 30°C

These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed.

Connection and Components

The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram.

The legacy terminal-connector type is PL2925. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities.

Dimensions and Weight

Parameter Details
Bore diameter 11.6 mm
Separate coil envelope dimensions Not listed in this supplied coil page
Separate coil weight Not listed; no complete-valve mass is substituted

For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

Coil Ordering Options

Parameter Details
Connection CD = terminal; CL = grommet
Bore family A116 = Ø11.6 mm; A170 = Ø17.0 mm
Valve-type code No separate valve-type position is shown in the legacy coil ordering code
Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V
Heat-class code Omitted = Class B; H = Class H

Reference Weight

Estimated reference weight: 130 g. The mass reference is the DOLD listing for CDA116CH, which lists an item weight of 130 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The same size and electrical-entry coil family supplies the reference; any voltage, insulation or normally open option difference is not independently mass-corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

Product form

Specifications: CDA116FH is an AirTAC 116-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A116 identifies... Read more

SKU: CDA116FH

$15.21 Incl. VAT

    Guaranteed secure & safe checkout.

    Ach Direct DebitAmazon American Express Apple Pay BizumDiners ClubDiscoverGoogle Pay Mastercard MB WAY PayPalSatispayShop Pay USDC Visa

    Bank transfer also available. Payment options may vary by location and device.

    Shipping, returns & order help

    Free shipping on orders US$30+ under 2 kg

    Import duties & taxes included on all orders

    Download: 3D model selection.
    Shipping & delivery times

    In-stock items: processed and shipped within 1–3 business days. Custom-made items: G/NPT threads and non-standard specifications require 7–15 business days of factory production before shipping.

    Standard international delivery typically takes 7–13 business days after dispatch, depending on customs clearance and the local delivery network. Processing or production time is additional. Next-day and overnight delivery are not available.

    Most products ship from our manufacturing centers in Asia, then transfer to a local carrier after customs clearance.

    Read our shipping policy
    Shipping costs & import taxes

    Free shipping: orders of US$30 or more weighing under 2 kg. Import duties and taxes are included on all orders.

    If an overweight shipping surcharge applies after packing, we pause shipment and email you the amount for approval before dispatch. This is a transport charge, not an import tax. If you do not reply within 7 days, the order is canceled and fully refunded.

    Shipping charges and tax details
    Model selection & custom orders

    Please check the full model number, dimensions, thread type, stroke and voltage where applicable before ordering. If you are unsure, email airtacs@airtacs.com with the model number and required specifications.

    Custom-made products, including G/NPT thread specifications and custom-built parts, are non-returnable and non-refundable under our refund policy.

    Read the refund policy before ordering
    Tracking & delivery support

    Use the tracking link in your shipping confirmation email. For YunExpress shipments, enter your YT tracking number at Yuntrack to view the journey and local delivery details.

    Provide a complete physical delivery address and reachable contact details. P.O. boxes and virtual mail-forwarding addresses are not accepted.

    If delivery fails, contact the local carrier and email airtacs@airtacs.com with your order and tracking numbers. For failures caused by an incorrect/incomplete address or an unreachable recipient, return to the local warehouse typically takes 7–30 business days. Redelivery requires an additional shipping fee; cancellation after failed delivery is subject to deductions for original shipping and carrier return fees.

    Delivery issue policy
    Returns & product issues

    Eligible returns are accepted within 7 days of delivery. Items must be unused, uninstalled and in their original factory packaging. Contact airtacs@airtacs.com for a Return Authorization (RA) number before returning anything.

    Ordered the wrong model or changed your mind? You pay return shipping, original shipping is non-refundable, and a 50% restocking fee is deducted from the actual price paid for the returned product.

    Defective, damaged or incorrect item? We provide a replacement and cover return shipping; no restocking fee applies. Custom-made items are excluded from standard returns. These terms are subject to applicable law and do not limit your statutory rights.

    Read the full refund policy
    Bank transfers & invoices

    Bank transfer: Select bank transfer at checkout and submit your order. The bank account details and payment instructions will then be displayed.

    Invoices: Invoices are available only after an order is placed. We are a US-based company and provide a standard commercial invoice, not an EU VAT tax invoice. If your company requires an EU VAT invoice, please confirm your requirements with us before ordering.

    For payment or invoice questions, email airtacs@airtacs.com with your order number.

    Description

    Specifications: CDA116FH is an AirTAC 116-series solenoid coil, not a complete valve. CD specifies terminal / DIN connection; A116 identifies an 11.6 mm coil bore; F selects DC12V; H selects Class H. The legacy ordering code has no separate normally-open K field. This exact order is listed for 2L, 2KL; applicable size groups and connection conditions are listed below.

    Product Catalogs and Comparison Guide

    Download Airtac Coil and Accessories Catalog (PDF)

    Download Airtac 2KL Product Catalog (PDF)

    Download Airtac 2KLA Product Catalog (PDF)

    For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

    AirTAC 2KL vs 2KLA: Dimensions and Replacement Guide

    The valve catalogs and comparison guide provide series background. They do not turn this separately ordered component into a complete valve or establish an automatic component replacement.

    Applicable Valve Series and Ordering Check

    Applicable valve series for CDA116FH: 2L, 2KL. Only the model groups in the table below are listed for this exact coil selection. The coil has an 11.6 mm bore, terminal / DIN entry, DC12V supply and Class H insulation. Match all four conditions to the valve and existing coil.

    Valve series and normal state Applicable valve model groups
    2L — normally closed (NC) 2L030, 2L150, 2L200, 2L250 model groups.
    2KL — normally open (NO) 2KL030, 2KL150, 2KL200, 2KL250 model groups.

    The legacy 116/170 coil ordering code has no K position. The catalog lists the normally-closed and normally-open valve groups separately, as shown above, and separates their electrical ratings where applicable. Follow the matching NC or NO rating and the actual coil nameplate.

    The final H selects Class H. The application list follows the legacy "Coil and accessories" selection table on printed page 205; it does not extend this coil to newer A-series valves.

    These are model-group names, not complete valve ordering codes. The 030 groups in the selection chart include an intervening pressure-option position. Keep any such pressure option and all port, thread, voltage and electrical-entry suffixes of the actual valve order. The other model groups listed above are discrete catalog codes, not a continuous numerical range.

    Ordering check: order CDA116FH for the listed valve groups when DC12V, terminal / DIN entry, an 11.6 mm bore and Class H are required. Confirm the complete valve code, installed coil marking and normal state before replacement.

    The legacy hookup table identifies PL2925 as the connector type for this CDA116 terminal-coil family. The connector and coil have separate ordering codes; the catalog does not establish a sales-package contents list.

    A Class H coil is not automatically interchangeable with another insulation class or generation. The older 116/170 bores are 11.6/17.0 mm; the newer 110/160 bores are 10.0/16.0 mm. These physical differences prevent a simple “add A” coil substitution.

    Component Identity and Ordering

    Parameter Details
    Product type Separately ordered solenoid coil
    Current ordering code CDA116FH
    Coil-bore code A116 — 11.6 mm bore
    Electrical entry CD — terminal / DIN
    Voltage F — DC12V
    Valve-type position NC/NO use selected by the valve application; the old coil code has no K position
    Insulation suffix H — Class H
    Automatic replacement No automatic A-suffix conversion is established for coils. Confirm the valve, bore, voltage, normal state and insulation class.

    Coil Electrical Data

    Parameter Details
    Voltage tolerance ±10%
    Frequency DC; not applicable
    Insulation class for this order H
    Power consumption, NC or NO application 6.5 W
    Temperature rise, NC or NO application 30°C

    These are the independent coil-page values, not values copied from a complete valve. Pressure, fluid temperature, valve-body material and valve flow coefficient are not specifications of this loose coil. No separate coil weight is listed.

    Connection and Components

    The hookup drawing places the coil across numbered terminals 1 and 2 for the shown AC/DC connection. Match the ordered voltage and follow the source diagram.

    The legacy terminal-connector type is PL2925. The exploded connector illustration identifies the screw, terminal shell, terminal core and terminal washer. The page identifies parts but does not state that a loose coil includes every connector component or provide quantities.

    Dimensions and Weight

    Parameter Details
    Bore diameter 11.6 mm
    Separate coil envelope dimensions Not listed in this supplied coil page
    Separate coil weight Not listed; no complete-valve mass is substituted

    For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

    Coil Ordering Options

    Parameter Details
    Connection CD = terminal; CL = grommet
    Bore family A116 = Ø11.6 mm; A170 = Ø17.0 mm
    Valve-type code No separate valve-type position is shown in the legacy coil ordering code
    Voltage A = AC220V; B = DC24V; C = AC110V; E = AC24V; F = DC12V
    Heat-class code Omitted = Class B; H = Class H

    Reference Weight

    Estimated reference weight: 130 g. The mass reference is the DOLD listing for CDA116CH, which lists an item weight of 130 g. This is a supplier listing reference, not an AirTAC catalog net-weight specification. The same size and electrical-entry coil family supplies the reference; any voltage, insulation or normally open option difference is not independently mass-corrected. This is a reference estimate, not a manufacturer-published weight for this exact configuration or an individually measured or packaged shipping weight. Actual supplied mass can differ.

    Recently viewed products

      Footer image

      © 2026 Airtac, Powered by Shopify

      • US (USD $) US (USD $)
      • Ach Direct Debit
      • Amazon
      • American Express
      • Apple Pay
      • Bizum
      • Diners Club
      • Discover
      • Google Pay
      • Mastercard
      • MB WAY
      • PayPal
      • Satispay
      • Shop Pay
      • USDC
      • Visa