Specifications: SCJ200X296-100 — Airtac SCJ double-rod, double-acting stroke-adjustable tie-rod cylinder; 200 mm bore, 296 mm nominal stroke, 100 mm adjustment option, without magnet, NBR seal option and PT3/4 working ports.

Product Catalog

Download Airtac Product Catalog (PDF)

For product dimensions and mounting drawings, download and refer to the PDF catalog.

Model Code Explained

Code Meaning
SCJ Double-rod, double-acting cylinder with adjustable stroke
200 200 mm bore
X Separator before nominal stroke
296 296 mm nominal stroke
- Separator before adjustment stroke
100 100 mm adjustment-stroke option
No magnet suffix Without built-in magnet
No mounting suffix Basic mounting
No seal-material suffix NBR seal option
No thread suffix PT3/4 working ports

Technical Specifications

Parameter Value
Model SCJ200X296-100
Action Double acting, double rod, adjustable stroke
Bore 200 mm
Nominal stroke 296 mm; Special stroke; confirm order and delivery conditions
Adjustment stroke 100 mm adjustment option, not a second powered stroke
Construction Tie-rod; ISO6430: SC-family design reference, not verified SCJ overall conformity
Magnetic piston Without magnet; magnetic sensors require an S cylinder
Mounting selection Basic mounting
Seal option NBR; basic O-ring materials are family references
Port thread PT3/4; two working air ports
Working medium Clean compressed air; 40 µm or finer filtration
Operating pressure 0.15–1.0 MPa (1.5–10 bar; approximately 22–145 psi)
Proof pressure 1.5 MPa (15 bar); not continuous operating pressure
Operating temperature −20 to 70 °C; avoid freezing condensate
Piston speed 30–500 mm/s; match controls to load, piping and adjustment
Nominal-stroke tolerance +1.5 / 0 mm
Cushioning Adjustable pneumatic cushioning; 33 mm nominal cushion-stroke reference
Rod diameter / end thread 40 mm / M36×2.0
Sensor selection Magnetic sensing requires an S cylinder; a sensor adds no magnet
Estimated cylinder weight 21471 g; engineering reference, not measured shipping weight

Engineering weight estimate using the same-bore SC catalog as a baseline plus an equivalent extra-rod allowance with representative steel density. The adjustment mechanism, changed covers and internal details are not separately mass-resolved. Mounts, rod-end joints, sensors, fittings and packaging are excluded. This is not an official SCJ net mass or a measured shipping weight; no error bound is established. Use the actual weighed assembly for handling and shipping.

Confirm actual travel, stop setting and end positions; the adjustment code alone does not specify usable travel. Check cushioning at the setting; strokes shorter than 33 mm cannot provide full nominal cushion travel.

Features and Operation

SCJ provides double-acting through-rod motion and stroke adjustment. Family references: aluminium-alloy barrel and covers with tie rods, compact bidirectional grease-retaining piston seal, adjustable pneumatic cushioning.

Confirm the ordered cylinder for the 150 °C special-seal feature; this NBR configuration remains −20 to 70 °C.

External and Mounting Dimensions

Dimensions: mm except threads; magnetic/nonmagnetic basic dimensions are equal. Drawing lengths do not guarantee the installed/moving envelope. Check clearance for both rods, adjustment, mounts, rod joints, fittings and sensors.

Parameter Value
Overall drawing reference: A + 2 × stroke + adjustment 1034 mm = 342 + 2 × 296 + 100
Body face span: AC + stroke 422 mm = 126 + 296
Rear drawing span: DB + stroke + adjustment 464 mm = 68 + 296 + 100
Rear adjustment reference: DB + adjustment 168 mm = 68 + 100
Body width × height 214 × 214 mm (□B)
Mounting holes 8 × M16×2.0 (K), 21 mm deep (KA); 163 × 163 mm centers (□KB)
Rod diameter / end thread D = 40 mm; E = M36×2.0; EA = 72 mm
Front locating and local geometry M = 62; MA = 30; AB = 118; DA = 88; F = 55; FA = 18; H = 36 mm
Cover / port local geometry AD = 38; AE = 38; PA = 20; PB = 15 mm; P = PT3/4

Mounting and Rod-End Accessories

Mounting: basic, LB, FA or TC with TCM1; match load direction and motion. Listed parts do not imply included supply/quantity. Confirm assembly and support quantities for seller-defined TC+TCM1.

Part / assembly code Application and reference
F-SC200LB Foot mount; Ductile cast iron
F-SC200FA Front flange; Ductile cast iron
F-SC200TC Trunnion mount; Ductile cast iron; order with the cylinder and match TCM1
F-SC160TCM1 Trunnion support; Ductile cast iron
F-M36X200I I-type rod-end joint; 2176 g catalog reference. Drawing dimensions: NC = 35; ND = 144; NE = 181; NF = 65; NG = 55; NH = M36×2.0; NM = 35.
F-M36X200Y Y-type rod-end joint; 3083.8 g catalog reference. Drawing dimensions: NA = 70; NC = 35; ND = 144; NP = 73; NQ = 179; NM = 35; NH = M36×2.0; PA = 80.2; PB = 70.8.
F-M36X200F Floating joint; 4126 g catalog reference. Drawing dimensions: MA = 194.5; MB = 60; MC = 20.5; MD = 77.5; ME = 84; MF = 54; MG = 18; MH = 36; MI/MJ = M36×2.0; MK = 5°.
F-M36X200U Spherical rod-end joint; 1664 g catalog reference. Drawing dimensions: PA = 27.5; PB = 80; PC = 35; PD = 56; PE = 125; PF = 165; PG = M36×2.0; PH = 15°; PI = 57.5; PJ = 50; PK = 43.

The rod-end choices use M36×2.0. Dimensions are in mm except threads and angles. MK is floating-joint angular compensation. PH is the spherical-joint angle. Carbon-steel classification does not specify all subcomponents/finishes. Add only supplied accessory mass. The floating-joint radial-offset note for M6 and smaller does not apply.

Verify genuine SCJ seal kits, wear rings, guide bushings, nuts, covers and adjustment parts by exact model, seal and production revision. Drawing numbers and bore size are not service ordering codes. This nonmagnetic configuration has no built-in magnet.

Force and Circuit Selection

Parameter Value
Ideal effective area, both directions 30159.29 mm² = π / 4 × (200² − 40²)
Calculated force at 0.5 MPa, both directions 15079.64 N
Force calculation Force (N) = annular pressure area (mm²) × pressure (MPa), before friction, backpressure and dynamic losses
Load-ratio guidance Up to 0.7 at static/low speed, 0.5 at 50–500 mm/s and 0.3 above 500 mm/s, subject to cylinder speed limits; not guaranteed payload/structural safety factors

Equal-diameter through-rod calculation. Size for annular area, load, adjusted travel, line losses, valve flow and exhaust backpressure; bore alone does not determine speed/payload.

Installation and Maintenance

Qualified staff must select, install and service the system. Guard both moving rod ends and secure the cylinder, loads and attachments. Before service or adjustment, isolate air and electricity, vent pressure and secure motion. Design safe responses to air/power loss, emergency stops and restart.

Check protection from corrosive gas, chemicals, solvents, salt, water or steam, explosive atmospheres, vibration, radiant heat and sunlight. Protect sliding surfaces from damage, dust, humidity, splashes, oil and coolant. Prevent condensate freezing; external magnetic fields may disturb magnetic sensing.

Use clean, dry, purified compressed air. Remove water, particles, oxidized oil, tar and carbon; filter to 40 µm or finer. Confirm suitability for other fluids and synthetic-oil contaminants. Excessively dry air may shorten life unless the component is designed for it.

Factory lubrication normally needs no added oil. Once oil is introduced, continue additive-free ISO-VG32 turbine oil; incompatible oil may swell seals. The guide gives oil mist ≤25 mg/m³ and 0.5–5 drops per 1000 L. Size the lubricator for actual flow and avoid excess oil.

Blow pipes clean; start sealing tape 1.5–2 threads back to keep fragments out. Use suitable flame-resistant or metal tube near hot spatter. Check each tube’s pressure, temperature, OD, ID and bend radius; generic nylon/PU advice cannot override its rating.

PT3/4 piping torque: 28–30 N·m with the specified mating connection; not a G/NPT installation or sensor-adjustment torque.

Use speed controls at both working ports; start closed and open slowly. Meter-out commonly stabilizes motion and reduces startup runout. Adjust cushioning gradually for the load and speed, avoiding impact, rebound or forcing its screw. High mass or speed may need engineered deceleration or an external absorber.

Air compressibility and leakage prevent assuming precise prolonged intermediate stopping with a closed-center valve or precise cylinder synchronization. Verify the adjusted travel, mechanical stop setting, available cushioning, air consumption and clearances for the actual application.

Align rod and load motion and provide independent guidance against side load, bending and torque. Check long-rod buckling, sag and vibration; support long spans and limit unsupported lever arms. Use a suitable TC pivot arrangement for swinging motion rather than forcing a rigid LB mount. Check bracket loads and flange orientation.

During long storage, operate periodically and prevent corrosion, following the air-quality and lubrication requirements.

Internal Components — Family Reference

Materials below are basic SC-family references. Not a complete SCJ double-rod/adjustment-mechanism BOM. Item numbers identify drawing references, not service codes; verify parts for the production revision.

Family drawing item Basic material reference
1 — Rod-end nut Carbon steel
2 — Piston rod S45C hard-chrome-plated ground rod
3 — Front-cover O-ring NBR
4 — Guide bushing Wear-resistant material
5 — Front cover Aluminium alloy
6 — Cushion O-ring TPU
7 — O-type seal ring NBR
8 — Cylinder barrel Aluminium alloy
9 — Piston Aluminium alloy
10 — Piston-rod O-ring NBR
11 — Piston O-ring NBR
12 — Magnet Not included in the nonmagnetic configuration
13 — Wear ring Wear-resistant material
14 — Hex-socket screw Carbon steel
15 — Rear cover Aluminium alloy
16 — Tie rod Carbon steel
17 — Tie-rod nut Carbon steel

Series Ordering Options

Parameter Value
Series identity SCJ: double-rod, double-acting cylinder with adjustable stroke
Adjustment-stroke options 10, 20, 30, 40, 50, 75, 100 mm; second numeric slot after the hyphen
Magnet No suffix: without magnet; S: magnetic piston
Seal material No suffix: NBR; H: Fluororubber. This product uses the blank-code NBR.
Mounting Basic, LB, FA or TC with matching TCM1; TC+TCM1 package identifiers are seller-defined
Thread options PT, G and NPT; match the complete ordered port and fitting thread
Standard nominal strokes 25, 50, 75, 80, 100, 125, 150, 160, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm
Catalog nominal-stroke limits Maximum stroke 1500 mm; allowable stroke 2000 mm

The large-bore page gives no numerical non-standard-stroke threshold. Confirm ordering/delivery of other non-listed strokes. Match travel and clearance to the actual adjustment; it is not a powered stage.

Connection and Upstream Options

Complete ordering code Separately installed upstream filter/regulator
GAFR50020S two female PT3/4 ports; PC bowl, 108 cc; round gauge in MPa/psi
GAFR600C20S two female PT3/4 ports; Metal bowl, 205 cc; round gauge in MPa/psi

Select separate male PT3/4 fittings for both cylinder working ports, with tube OD/ID, flow capacity, seal and clearance matched to the installation. PT, G and NPT are not interchangeable. The M36×2.0 rod thread is not an air port.

The filter/regulators below are separate upstream options, not cylinder-port fittings or an included kit. Connect their IN/OUT ports with correctly matched male fittings. Do not fit a smaller male connector directly into a larger port; any adapter must match both thread sizes, standards and genders without restricting required flow.

These complete ordering examples use compressed air, a 40 µm element, differential-pressure/manual drain, included bracket and round gauge, standard regulation and no reverse-flow valve. The 500 series uses a PC bowl; 600C uses a metal bowl. Other configurations require their own ordering codes.

Maximum inlet pressure 1 MPa; proof pressure 1.5 MPa is not operating pressure. Adjustment range 0.15–0.9 MPa; temperature −5–70 °C, non-freezing. Observe flow/pressure loss, IN/OUT direction, condensate drainage, bowl environment and every downstream component limit. These are not vacuum regulators.

Size the valve, tubing and both endpoint connections for the required load, stroke, speed and pressure loss. Do not use a smaller-bore selection table as a guaranteed large-cylinder speed rating. Meter-out controls must match the actual port and circuit; valve-exhaust silencers must match that valve’s exhaust ports. Do not place silencers or plugs on either active cylinder port.

Tube OD and ID must match the specified fittings; inch tubing is not interchangeable with nominal metric tubing. A 16 × 11 mm tube requires separately specified 16 mm endpoint fittings and controls. Select the complete connection path before ordering; the upstream unit alone does not specify a full pneumatic circuit.

SCJ has two working ports and equal-diameter rods. Size flow using its annular pressure area, actual load, adjusted travel, piping losses and exhaust backpressure; a general bore-based chart does not guarantee SCJ speed.

Product form

Specifications: SCJ200X296-100 — Airtac SCJ double-rod, double-acting stroke-adjustable tie-rod cylinder; 200 mm bore, 296 mm nominal stroke, 100 mm adjustment... Read more

SKU: SCJ200X296-100

$1,325.78 Incl. VAT

    Guaranteed secure & safe checkout.

    Ach Direct DebitAmazon American Express Apple Pay BizumDiners ClubDiscoverGoogle Pay Mastercard MB WAY PayPalSatispayShop Pay USDC Visa

    Bank transfer also available. Payment options may vary by location and device.

    Shipping, returns & order help

    Free shipping on orders US$30+ under 2 kg

    Import duties & taxes included on all orders

    Download: 3D model selection.
    Shipping & delivery times

    In-stock items: processed and shipped within 1–3 business days. Custom-made items: G/NPT threads and non-standard specifications require 7–15 business days of factory production before shipping.

    Standard international delivery typically takes 7–13 business days after dispatch, depending on customs clearance and the local delivery network. Processing or production time is additional. Next-day and overnight delivery are not available.

    Most products ship from our manufacturing centers in Asia, then transfer to a local carrier after customs clearance.

    Read our shipping policy
    Shipping costs & import taxes

    Free shipping: orders of US$30 or more weighing under 2 kg. Import duties and taxes are included on all orders.

    If an overweight shipping surcharge applies after packing, we pause shipment and email you the amount for approval before dispatch. This is a transport charge, not an import tax. If you do not reply within 7 days, the order is canceled and fully refunded.

    Shipping charges and tax details
    Model selection & custom orders

    Please check the full model number, dimensions, thread type, stroke and voltage where applicable before ordering. If you are unsure, email airtacs@airtacs.com with the model number and required specifications.

    Custom-made products, including G/NPT thread specifications and custom-built parts, are non-returnable and non-refundable under our refund policy.

    Read the refund policy before ordering
    Tracking & delivery support

    Use the tracking link in your shipping confirmation email. For YunExpress shipments, enter your YT tracking number at Yuntrack to view the journey and local delivery details.

    Provide a complete physical delivery address and reachable contact details. P.O. boxes and virtual mail-forwarding addresses are not accepted.

    If delivery fails, contact the local carrier and email airtacs@airtacs.com with your order and tracking numbers. For failures caused by an incorrect/incomplete address or an unreachable recipient, return to the local warehouse typically takes 7–30 business days. Redelivery requires an additional shipping fee; cancellation after failed delivery is subject to deductions for original shipping and carrier return fees.

    Delivery issue policy
    Returns & product issues

    Eligible returns are accepted within 7 days of delivery. Items must be unused, uninstalled and in their original factory packaging. Contact airtacs@airtacs.com for a Return Authorization (RA) number before returning anything.

    Ordered the wrong model or changed your mind? You pay return shipping, original shipping is non-refundable, and a 50% restocking fee is deducted from the actual price paid for the returned product.

    Defective, damaged or incorrect item? We provide a replacement and cover return shipping; no restocking fee applies. Custom-made items are excluded from standard returns. These terms are subject to applicable law and do not limit your statutory rights.

    Read the full refund policy
    Bank transfers & invoices

    Bank transfer: Select bank transfer at checkout and submit your order. The bank account details and payment instructions will then be displayed.

    Invoices: Invoices are available only after an order is placed. We are a US-based company and provide a standard commercial invoice, not an EU VAT tax invoice. If your company requires an EU VAT invoice, please confirm your requirements with us before ordering.

    For payment or invoice questions, email airtacs@airtacs.com with your order number.

    Description

    Specifications: SCJ200X296-100 — Airtac SCJ double-rod, double-acting stroke-adjustable tie-rod cylinder; 200 mm bore, 296 mm nominal stroke, 100 mm adjustment option, without magnet, NBR seal option and PT3/4 working ports.

    Product Catalog

    Download Airtac Product Catalog (PDF)

    For product dimensions and mounting drawings, download and refer to the PDF catalog.

    Model Code Explained

    Code Meaning
    SCJ Double-rod, double-acting cylinder with adjustable stroke
    200 200 mm bore
    X Separator before nominal stroke
    296 296 mm nominal stroke
    - Separator before adjustment stroke
    100 100 mm adjustment-stroke option
    No magnet suffix Without built-in magnet
    No mounting suffix Basic mounting
    No seal-material suffix NBR seal option
    No thread suffix PT3/4 working ports

    Technical Specifications

    Parameter Value
    Model SCJ200X296-100
    Action Double acting, double rod, adjustable stroke
    Bore 200 mm
    Nominal stroke 296 mm; Special stroke; confirm order and delivery conditions
    Adjustment stroke 100 mm adjustment option, not a second powered stroke
    Construction Tie-rod; ISO6430: SC-family design reference, not verified SCJ overall conformity
    Magnetic piston Without magnet; magnetic sensors require an S cylinder
    Mounting selection Basic mounting
    Seal option NBR; basic O-ring materials are family references
    Port thread PT3/4; two working air ports
    Working medium Clean compressed air; 40 µm or finer filtration
    Operating pressure 0.15–1.0 MPa (1.5–10 bar; approximately 22–145 psi)
    Proof pressure 1.5 MPa (15 bar); not continuous operating pressure
    Operating temperature −20 to 70 °C; avoid freezing condensate
    Piston speed 30–500 mm/s; match controls to load, piping and adjustment
    Nominal-stroke tolerance +1.5 / 0 mm
    Cushioning Adjustable pneumatic cushioning; 33 mm nominal cushion-stroke reference
    Rod diameter / end thread 40 mm / M36×2.0
    Sensor selection Magnetic sensing requires an S cylinder; a sensor adds no magnet
    Estimated cylinder weight 21471 g; engineering reference, not measured shipping weight

    Engineering weight estimate using the same-bore SC catalog as a baseline plus an equivalent extra-rod allowance with representative steel density. The adjustment mechanism, changed covers and internal details are not separately mass-resolved. Mounts, rod-end joints, sensors, fittings and packaging are excluded. This is not an official SCJ net mass or a measured shipping weight; no error bound is established. Use the actual weighed assembly for handling and shipping.

    Confirm actual travel, stop setting and end positions; the adjustment code alone does not specify usable travel. Check cushioning at the setting; strokes shorter than 33 mm cannot provide full nominal cushion travel.

    Features and Operation

    SCJ provides double-acting through-rod motion and stroke adjustment. Family references: aluminium-alloy barrel and covers with tie rods, compact bidirectional grease-retaining piston seal, adjustable pneumatic cushioning.

    Confirm the ordered cylinder for the 150 °C special-seal feature; this NBR configuration remains −20 to 70 °C.

    External and Mounting Dimensions

    Dimensions: mm except threads; magnetic/nonmagnetic basic dimensions are equal. Drawing lengths do not guarantee the installed/moving envelope. Check clearance for both rods, adjustment, mounts, rod joints, fittings and sensors.

    Parameter Value
    Overall drawing reference: A + 2 × stroke + adjustment 1034 mm = 342 + 2 × 296 + 100
    Body face span: AC + stroke 422 mm = 126 + 296
    Rear drawing span: DB + stroke + adjustment 464 mm = 68 + 296 + 100
    Rear adjustment reference: DB + adjustment 168 mm = 68 + 100
    Body width × height 214 × 214 mm (□B)
    Mounting holes 8 × M16×2.0 (K), 21 mm deep (KA); 163 × 163 mm centers (□KB)
    Rod diameter / end thread D = 40 mm; E = M36×2.0; EA = 72 mm
    Front locating and local geometry M = 62; MA = 30; AB = 118; DA = 88; F = 55; FA = 18; H = 36 mm
    Cover / port local geometry AD = 38; AE = 38; PA = 20; PB = 15 mm; P = PT3/4

    Mounting and Rod-End Accessories

    Mounting: basic, LB, FA or TC with TCM1; match load direction and motion. Listed parts do not imply included supply/quantity. Confirm assembly and support quantities for seller-defined TC+TCM1.

    Part / assembly code Application and reference
    F-SC200LB Foot mount; Ductile cast iron
    F-SC200FA Front flange; Ductile cast iron
    F-SC200TC Trunnion mount; Ductile cast iron; order with the cylinder and match TCM1
    F-SC160TCM1 Trunnion support; Ductile cast iron
    F-M36X200I I-type rod-end joint; 2176 g catalog reference. Drawing dimensions: NC = 35; ND = 144; NE = 181; NF = 65; NG = 55; NH = M36×2.0; NM = 35.
    F-M36X200Y Y-type rod-end joint; 3083.8 g catalog reference. Drawing dimensions: NA = 70; NC = 35; ND = 144; NP = 73; NQ = 179; NM = 35; NH = M36×2.0; PA = 80.2; PB = 70.8.
    F-M36X200F Floating joint; 4126 g catalog reference. Drawing dimensions: MA = 194.5; MB = 60; MC = 20.5; MD = 77.5; ME = 84; MF = 54; MG = 18; MH = 36; MI/MJ = M36×2.0; MK = 5°.
    F-M36X200U Spherical rod-end joint; 1664 g catalog reference. Drawing dimensions: PA = 27.5; PB = 80; PC = 35; PD = 56; PE = 125; PF = 165; PG = M36×2.0; PH = 15°; PI = 57.5; PJ = 50; PK = 43.

    The rod-end choices use M36×2.0. Dimensions are in mm except threads and angles. MK is floating-joint angular compensation. PH is the spherical-joint angle. Carbon-steel classification does not specify all subcomponents/finishes. Add only supplied accessory mass. The floating-joint radial-offset note for M6 and smaller does not apply.

    Verify genuine SCJ seal kits, wear rings, guide bushings, nuts, covers and adjustment parts by exact model, seal and production revision. Drawing numbers and bore size are not service ordering codes. This nonmagnetic configuration has no built-in magnet.

    Force and Circuit Selection

    Parameter Value
    Ideal effective area, both directions 30159.29 mm² = π / 4 × (200² − 40²)
    Calculated force at 0.5 MPa, both directions 15079.64 N
    Force calculation Force (N) = annular pressure area (mm²) × pressure (MPa), before friction, backpressure and dynamic losses
    Load-ratio guidance Up to 0.7 at static/low speed, 0.5 at 50–500 mm/s and 0.3 above 500 mm/s, subject to cylinder speed limits; not guaranteed payload/structural safety factors

    Equal-diameter through-rod calculation. Size for annular area, load, adjusted travel, line losses, valve flow and exhaust backpressure; bore alone does not determine speed/payload.

    Installation and Maintenance

    Qualified staff must select, install and service the system. Guard both moving rod ends and secure the cylinder, loads and attachments. Before service or adjustment, isolate air and electricity, vent pressure and secure motion. Design safe responses to air/power loss, emergency stops and restart.

    Check protection from corrosive gas, chemicals, solvents, salt, water or steam, explosive atmospheres, vibration, radiant heat and sunlight. Protect sliding surfaces from damage, dust, humidity, splashes, oil and coolant. Prevent condensate freezing; external magnetic fields may disturb magnetic sensing.

    Use clean, dry, purified compressed air. Remove water, particles, oxidized oil, tar and carbon; filter to 40 µm or finer. Confirm suitability for other fluids and synthetic-oil contaminants. Excessively dry air may shorten life unless the component is designed for it.

    Factory lubrication normally needs no added oil. Once oil is introduced, continue additive-free ISO-VG32 turbine oil; incompatible oil may swell seals. The guide gives oil mist ≤25 mg/m³ and 0.5–5 drops per 1000 L. Size the lubricator for actual flow and avoid excess oil.

    Blow pipes clean; start sealing tape 1.5–2 threads back to keep fragments out. Use suitable flame-resistant or metal tube near hot spatter. Check each tube’s pressure, temperature, OD, ID and bend radius; generic nylon/PU advice cannot override its rating.

    PT3/4 piping torque: 28–30 N·m with the specified mating connection; not a G/NPT installation or sensor-adjustment torque.

    Use speed controls at both working ports; start closed and open slowly. Meter-out commonly stabilizes motion and reduces startup runout. Adjust cushioning gradually for the load and speed, avoiding impact, rebound or forcing its screw. High mass or speed may need engineered deceleration or an external absorber.

    Air compressibility and leakage prevent assuming precise prolonged intermediate stopping with a closed-center valve or precise cylinder synchronization. Verify the adjusted travel, mechanical stop setting, available cushioning, air consumption and clearances for the actual application.

    Align rod and load motion and provide independent guidance against side load, bending and torque. Check long-rod buckling, sag and vibration; support long spans and limit unsupported lever arms. Use a suitable TC pivot arrangement for swinging motion rather than forcing a rigid LB mount. Check bracket loads and flange orientation.

    During long storage, operate periodically and prevent corrosion, following the air-quality and lubrication requirements.

    Internal Components — Family Reference

    Materials below are basic SC-family references. Not a complete SCJ double-rod/adjustment-mechanism BOM. Item numbers identify drawing references, not service codes; verify parts for the production revision.

    Family drawing item Basic material reference
    1 — Rod-end nut Carbon steel
    2 — Piston rod S45C hard-chrome-plated ground rod
    3 — Front-cover O-ring NBR
    4 — Guide bushing Wear-resistant material
    5 — Front cover Aluminium alloy
    6 — Cushion O-ring TPU
    7 — O-type seal ring NBR
    8 — Cylinder barrel Aluminium alloy
    9 — Piston Aluminium alloy
    10 — Piston-rod O-ring NBR
    11 — Piston O-ring NBR
    12 — Magnet Not included in the nonmagnetic configuration
    13 — Wear ring Wear-resistant material
    14 — Hex-socket screw Carbon steel
    15 — Rear cover Aluminium alloy
    16 — Tie rod Carbon steel
    17 — Tie-rod nut Carbon steel

    Series Ordering Options

    Parameter Value
    Series identity SCJ: double-rod, double-acting cylinder with adjustable stroke
    Adjustment-stroke options 10, 20, 30, 40, 50, 75, 100 mm; second numeric slot after the hyphen
    Magnet No suffix: without magnet; S: magnetic piston
    Seal material No suffix: NBR; H: Fluororubber. This product uses the blank-code NBR.
    Mounting Basic, LB, FA or TC with matching TCM1; TC+TCM1 package identifiers are seller-defined
    Thread options PT, G and NPT; match the complete ordered port and fitting thread
    Standard nominal strokes 25, 50, 75, 80, 100, 125, 150, 160, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm
    Catalog nominal-stroke limits Maximum stroke 1500 mm; allowable stroke 2000 mm

    The large-bore page gives no numerical non-standard-stroke threshold. Confirm ordering/delivery of other non-listed strokes. Match travel and clearance to the actual adjustment; it is not a powered stage.

    Connection and Upstream Options

    Complete ordering code Separately installed upstream filter/regulator
    GAFR50020S two female PT3/4 ports; PC bowl, 108 cc; round gauge in MPa/psi
    GAFR600C20S two female PT3/4 ports; Metal bowl, 205 cc; round gauge in MPa/psi

    Select separate male PT3/4 fittings for both cylinder working ports, with tube OD/ID, flow capacity, seal and clearance matched to the installation. PT, G and NPT are not interchangeable. The M36×2.0 rod thread is not an air port.

    The filter/regulators below are separate upstream options, not cylinder-port fittings or an included kit. Connect their IN/OUT ports with correctly matched male fittings. Do not fit a smaller male connector directly into a larger port; any adapter must match both thread sizes, standards and genders without restricting required flow.

    These complete ordering examples use compressed air, a 40 µm element, differential-pressure/manual drain, included bracket and round gauge, standard regulation and no reverse-flow valve. The 500 series uses a PC bowl; 600C uses a metal bowl. Other configurations require their own ordering codes.

    Maximum inlet pressure 1 MPa; proof pressure 1.5 MPa is not operating pressure. Adjustment range 0.15–0.9 MPa; temperature −5–70 °C, non-freezing. Observe flow/pressure loss, IN/OUT direction, condensate drainage, bowl environment and every downstream component limit. These are not vacuum regulators.

    Size the valve, tubing and both endpoint connections for the required load, stroke, speed and pressure loss. Do not use a smaller-bore selection table as a guaranteed large-cylinder speed rating. Meter-out controls must match the actual port and circuit; valve-exhaust silencers must match that valve’s exhaust ports. Do not place silencers or plugs on either active cylinder port.

    Tube OD and ID must match the specified fittings; inch tubing is not interchangeable with nominal metric tubing. A 16 × 11 mm tube requires separately specified 16 mm endpoint fittings and controls. Select the complete connection path before ordering; the upstream unit alone does not specify a full pneumatic circuit.

    SCJ has two working ports and equal-diameter rods. Size flow using its annular pressure area, actual load, adjusted travel, piping losses and exhaust backpressure; a general bore-based chart does not guarantee SCJ speed.

    Recently viewed products

      Footer image

      © 2026 Airtac, Powered by Shopify

      • US (USD $) US (USD $)
      • Ach Direct Debit
      • Amazon
      • American Express
      • Apple Pay
      • Bizum
      • Diners Club
      • Discover
      • Google Pay
      • Mastercard
      • MB WAY
      • PayPal
      • Satispay
      • Shop Pay
      • USDC
      • Visa