Specifications: SAI100BX1475FTC — SAI series double-acting single-rod cylinder; 100 mm bore × 1475 mm stroke; SUS304 rod (B); non-magnetic piston; front-cover trunnion mounting (FTC); TPU seals; PT1/2 ports.
Product Catalog
Download Airtac Product Catalog (PDF)
For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.
SI to SAI replacement guide
Model Code Explained
| Code |
Meaning |
| SAI |
Standard double-acting single-rod cylinder |
| 100 |
100 mm bore |
| B |
SUS304 stainless steel |
| X |
Separator before stroke |
| 1475 |
1475 mm stroke |
| No magnet suffix |
Without built-in magnet |
| FTC |
Front-cover trunnion mounting |
| No seal suffix |
TPU seal option |
| No thread suffix |
PT1/2 working ports |
Technical Specifications
| Parameter |
Value |
| Model |
SAI100BX1475FTC |
| Action |
Double acting, single rod |
| Bore |
100 mm |
| Stroke |
1475 mm; Special stroke; confirm order and delivery conditions |
| Piston rod material |
SUS304 stainless steel |
| Magnetic piston |
Without magnet |
| Mounting selection |
Front-cover trunnion mounting |
| Seal option |
TPU |
| Working ports |
PT1/2; two working air ports |
| Working medium |
Air filtered to 40 µm or finer |
| Operating pressure |
0.15–1 MPa (1.5–10 bar; approximately 22–145 psi) |
| Proof pressure |
1.5 MPa (15 bar); not continuous operating pressure |
| Temperature |
-20 to 70 °C; apply the complete system limits |
| Piston speed |
30–800 mm/s |
| Stroke tolerance |
+2 / -0 mm |
| Cushioning |
Adjustable pneumatic cushion; 36 mm nominal cushion reference |
| Rod diameter / end thread |
25 mm / M20×1.5 |
| Cylinder reference weight |
17013.5 g; catalog calculation, not measured shipping weight |
Reference weight = 3237 + 9.34 × 1475 g, decimal grams, from the matching non-magnetic SAI single-rod base. A/B rod and H/N seal mass differences are unquantified: not certified variant mass. Excludes brackets, rod joints, sensors and packaging; actual weight prevails.
The 36 mm nominal cushion distance does not guarantee usable deceleration length for shorter strokes. Verify actual load/speed performance.
Features and Operation
ISO15552 standard cylinder, formerly ISO6431.
Compact special-shaped bidirectional piston sealing structure with oil storage.
Corrosion-resistant profiled aluminium tube; no tie rods; external sensor grooves.
Stable adjustable pneumatic cushioning.
Multiple cylinder variants and mounting accessories available.
External and Mounting Dimensions
A+stroke ends at rear-cover face; overall formulas add rear boss NA once. Bare body excludes accessories, sensors, joints and packaging. Magnetic/nonmagnetic dimensions match. Drawing-specific symbols are not extra overall dimensions. Numbers are mm; threads are explicit. For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.
| Basic dimension / drawing symbol |
Dimension (mm) / thread |
| Illustrated A + stroke to rear-cover face |
1704 mm = 229 + 1475 |
| Body face span: AC + stroke |
1613 mm = 138 + 1475 |
| Derived bare retracted length: A + stroke + NA |
1708 mm = 229 + 1475 + 4 |
| Derived bare extended length: A + 2 × stroke + NA |
3183 mm = 229 + 2 × 1475 + 4 |
| Body cross-section |
115 × 115 mm |
| Base drawing symbols |
A=229 mm before adding the actual stroke;AB=91;AC=138 mm before adding the actual stroke;AD=37;AE=37;B=115;D=25;DA=55;E=M20×1.5;EA=40;F=26;FA=10;M=55;MA=36;H=22;K=M10;KA=19;KB=89;N=55;NA=4;P=PT1/2;PA=18.5;PB=9.5 |
Selected Mounting Dimensions
| Accessory / drawing symbols |
Dimension (mm) / thread |
| FTC — Front-cover trunnion mounting; F-SI100FTC |
A + stroke=1704 = 229 + 1475;C + stroke=1613 = 138 + 1475;AA=182;B=132;CA=25;D=89;E=114;F=35;K=16 |
Mounting and Rod-End Accessories
| Mounting option |
Part code and material |
| LB — Axial foot mounting |
F-SI100LB; Low-carbon steel |
| FA — Front flange mounting |
F-SI100FA; Aluminium alloy |
| CA — Single rear clevis |
F-SE100CA; Ductile cast iron |
| CB — Double rear clevis |
F-SE100CB; Ductile cast iron |
| CR — Single clevis connection |
F-SI100CR; Ductile cast iron |
| TC — Intermediate trunnion mounting |
F-SAI100TC; Ductile cast iron |
| FTC — Front-cover trunnion mounting |
F-SI100FTC; Ductile cast iron |
| TCM1 — Trunnion support type 1 |
F-SI125TCM1; Ductile cast iron |
| TCM2 — Trunnion support type 2 |
F-SI125TCM2; Aluminium alloy |
| FB — Rear flange mounting |
F-SI100FA; Aluminium alloy |
FA/FB share a flange plate at different positions. CR requires CB. TC/FTC need the listed TCM1/TCM2: support size numbers may differ from bore. Confirm package and fasteners.
TC is adjustable and separately orderable for this bore. Drawing-reference support centers: position for actual load.
TC locking torque: 8–10 N·m; static holding-force reference: 8000 N, not cylinder thrust or payload. Above this, specify factory nonstandard fixed TC. Place bracket on barrel ledges and position it. Pre-tighten; check bracket and barrel sloping faces contact. 50–125: tighten 8 black screws through pre-, intermediate and final tightening, then tighten 8 white screws.
Drawing holes: LB 4 AP; FA/FB 4 BP; CR 4 K through-holes and 4 L counterbores; TCM1 4 E; TCM2 4 L through-holes and 4 K counterbores. CA DQ/CB CP tolerance: ±0.1 mm. Hole counts do not specify supplied fastener quantities.
Rod-End Joint Dimensions
| Joint / drawing symbol |
Dimension (mm) / thread / angle |
| I joint — F-M20X150I |
NC=20;ND=80;NE=102;NF=40;NG=30;NH=M20×1.5;NM=20;Reference weight=608 g |
| Y clevis joint — F-M20X150Y |
NA=44.4;NC=20;ND=80;NP=40;NQ=101;NM=20;NH=M20×1.5;PA=53.4;PB=45.2;Reference weight=860 g |
| Floating joint — F-M20X150F |
MA=102;MB=29;MC=13;MD=46;ME=53;MF=22;MG=10;MH=22;MI_MJ=M20×1.5;MK=10°;Reference weight=865 g |
| Spherical rod-end joint — F-M20X150U |
PA=18;PB=46;PC=20;PD=33;PE=77;PF=100;PG=M20×1.5;PH=15°;PI=34;PJ=30;PK=25;Reference weight=370 g |
M20×1.5 rod joints use the carbon-steel catalog category; subparts/finishes are unspecified. Select joints/guides for load. Joint mass is excluded from cylinder weight. Y drawing: no separate pin-kit code or guaranteed kit count.
Service References — Confirm Exact Revision
| Parameter |
Value |
| TPU seal-set reference |
P-SAI100-R1 |
| NBR seal-set reference |
P-SAI100N-R1 |
| Fluororubber seal-set reference |
P-SAI100-R2 |
| Magnet-ring reference |
GMED77X96.5X5 |
| New-version magnet-ring reference |
GMED82.5X96.5X5 |
| Guide-ring reference |
SAI100 grooved wear-resistant guide ring associated with the magnet ring |
| Cover references |
SAI100 front cover; SAI100 rear cover |
The magnet ring labelled new version is a separate production-version reference. Select the ring against the actual cylinder production version and dimensions; do not assume interchangeability with the other listed reference.
Confirm revision, dimensions, material and fit for these original service references; interchangeability is unverified. Cover names are not order codes; seal alternatives are not all fitted.
Non-magnetic cylinder: magnet/guide-ring references imply neither a fitted magnet nor approved magnetic conversion.
Force and Application
| Parameter |
Value |
| Extension effective area |
7853 mm²; catalog rounded single-rod area |
| Extension at 0.5 MPa |
3926.5 N theoretical |
| Retraction effective area |
7362 mm²; catalog rounded single-rod area |
| Retraction at 0.5 MPa |
3681 N theoretical |
Theoretical axial force = effective area (mm²) × pressure (MPa), before friction/losses. Rod area reduces retraction area. Not safe working loads or guaranteed payloads.
Installation and Maintenance
Qualified personnel only. Before maintenance: secure loads, guard motion, isolate power/air and release residual pressure. Prevent unexpected restart motion; design for power/air loss.
Use clean, dry air filtered ≤40 µm; remove water, degraded oil and debris. Protect from dust, corrosion, coolant, weld spatter, vibration, heat and freezing; assess unusually dry air. Strong magnetic fields affect sensing.
Start unloaded; increase load gradually. Align rod/load; guide against side load, bending, impact and torque. Check long-stroke buckling, sag, support and air use. Rod joints do not replace guides.
Load-ratio guidance: ≤0.7 static/low speed; ≤0.5 at 50–500 mm/s; ≤0.3 above 500 mm/s. Not structural safety factors or payload guarantees; obey cylinder pressure/speed limits.
Fit flow controls at both ports; double action normally uses meter-out. Start closed; open gradually. Set cushions for load/speed without forcing screws. Heavy/fast loads may need an external absorber or deceleration circuit.
Compressibility/leakage defeat assumed precise prolonged closed-center stops or automatic multi-cylinder synchronization. Swing links need CA/CB/TC pivots, not rigid LB mounts forced through arcs. Match flange direction/support height to load.
Normally no added oil is needed. Once introduced, continuously use additive-free ISO-VG32 turbine oil. Oil-mist guide: ≤25 mg/m³; 0.5–5 drops per 1000 L. Size lubricator for flow; avoid excess/incompatible oil.
Clean pipes; keep sealant off leading threads. Start required tape 1.5–2 threads back. Verify tube pressure/temperature, OD/ID and bend radius. Hot spatter may require metal/flame-resistant tubing.
Protect sliding surfaces; periodically operate stored cylinders and prevent corrosion. Use the lowest cylinder/fitting/valve/tube/sensor/cable limit; temperature options do not raise other ratings.
PT1/2 mating piping-thread tightening reference: 12–15 N·m. This is not a G/NPT thread, TC clamp or sensor torque specification.
Internal Components — SAI Catalog Reference
| Item |
Material reference |
| 1. Nut |
Carbon steel / stainless steel |
| 2. Piston rod |
S45C hard-chrome-plated ground bar / stainless steel |
| 3. Front-cover O-ring |
TPU |
| 4. Front cover |
Aluminium alloy |
| 5. Bushing |
Wear-resistant material |
| 6. Cushion O-ring |
TPU |
| 7. Barrel |
Aluminium alloy |
| 8. Piston-rod O-ring |
NBR |
| 9. Piston |
Aluminium alloy |
| 10. Piston O-ring |
NBR |
| 11. Wear ring |
Wear-resistant material |
| 12. Magnet |
Not fitted in this non-magnetic cylinder. Catalog magnetic-version reference: Plastic type for bores100 and below; rubber type for other bores |
| 13. Hexagon socket bolt |
Carbon steel |
| 14. Cushion seal |
TPU |
| 15. Rear cover |
Aluminium alloy |
| 16. Support screw cap |
Carbon steel / stainless steel |
SAI structure reference, not an option material certificate. Ordered rod/seal choices prevail: A/B is not an all-stainless cylinder; a seal option does not replace every elastomer.
Series Ordering Options
| Parameter |
Value |
| Rod material choices |
Blank: Medium-carbon steel; A: SUS420J2 stainless steel; B: SUS304 stainless steel |
| Seal choices |
Blank: TPU; H: Fluororubber; N: NBR |
| Magnet choice |
Blank: no magnet; S: magnet fitted, sensors separately selected |
| Thread choices |
PT, G or NPT as specified by the actual order; do not mix thread standards |
| Catalog standard strokes |
25, 50, 75, 80, 100, 125, 150, 160, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 mm |
| Maximum / allowable stroke |
1500 / 1800 mm; separate catalog limits, not a list of all standard strokes |
| Stroke tolerance bands |
0–250 mm: +1 / -0 mm; 251–1000 mm: +1.5 / -0 mm; 1001–1500 mm: +2 / -0 mm; above 1500 mm not specified |
Series alternatives are not simultaneous features. Confirm special strokes/unlisted combinations. Retain the full model; separately select mounts, joints, sensors and circuit parts.
Magnetic Sensing
This model has no built-in magnet. DMSE and CMSE magnetic sensors are not applicable to this piston as ordered; adding a sensor does not add a magnet. A separately confirmed magnetic cylinder configuration is required for magnetic detection.
Connection and Tube-Side Options
| Separately selected component |
Complete ordering codes; tube dimensions as labelled |
| PC straight |
6 mm OD: PC604,PC604D,PC604-S,PC604D-S; 8 mm OD: PC804,PC804D,PC804-S,PC804D-S; 10 mm OD: PC1004,PC1004D,PC1004-S,PC1004D-S; 12 mm OD: PC1204,PC1204D,PC1204-S,PC1204D-S |
| POC round straight |
10 mm OD: POC1004,POC1004D,POC1004-S,POC1004D-S; 12 mm OD: POC1204,POC1204D,POC1204-S,POC1204D-S |
| PL elbow |
6 mm OD: PL604,PL604D,PL604-S,PL604D-S; 8 mm OD: PL804,PL804D,PL804-S,PL804D-S; 10 mm OD: PL1004,PL1004D,PL1004-S,PL1004D-S; 12 mm OD: PL1204,PL1204D,PL1204-S,PL1204D-S |
| PLL extended elbow |
10 mm OD: PLL1004,PLL1004D,PLL1004-S,PLL1004D-S; 12 mm OD: PLL1204,PLL1204D,PLL1204-S,PLL1204D-S |
| PEB branch tee |
8 mm OD: PEB804,PEB804D,PEB804-S,PEB804D-S; 10 mm OD: PEB1004,PEB1004D,PEB1004-S,PEB1004D-S; 12 mm OD: PEB1204,PEB1204D,PEB1204-S,PEB1204D-S |
| PED run tee |
8 mm OD: PED804,PED804D,PED804-S,PED804D-S; 10 mm OD: PED1004,PED1004D,PED1004-S,PED1004D-S; 12 mm OD: PED1204,PED1204D,PED1204-S,PED1204D-S |
| PYB Y fitting |
8 mm OD: PYB804,PYB804D,PYB804-S,PYB804D-S; 10 mm OD: PYB1004,PYB1004D,PYB1004-S,PYB1004D-S; 12 mm OD: PYB1204,PYB1204D,PYB1204-S,PYB1204D-S |
| PH banjo elbow |
8 mm OD: PH804,PH804D,PH804-S,PH804D-S; 10 mm OD: PH1004,PH1004D,PH1004-S,PH1004D-S; 12 mm OD: PH1204,PH1204D,PH1204-S,PH1204D-S |
| PHF female-branch banjo |
8 mm OD: PHF804,PHF804D,PHF804-S,PHF804D-S; 10 mm OD: PHF1004,PHF1004D,PHF1004-S,PHF1004D-S; 12 mm OD: PHF1204,PHF1204D,PHF1204-S,PHF1204D-S |
| PHW twin banjo |
8 mm OD: PHW804,PHW804D,PHW804-S,PHW804D-S; 10 mm OD: PHW1004,PHW1004D,PHW1004-S,PHW1004D-S; 12 mm OD: PHW1204,PHW1204D,PHW1204-S,PHW1204D-S |
| PZB cross fitting |
8 mm OD: PZB804,PZB804D,PZB804-S,PZB804D-S; 10 mm OD: PZB1004,PZB1004D,PZB1004-S,PZB1004D-S; 12 mm OD: PZB1204,PZB1204D,PZB1204-S,PZB1204D-S |
| BPC metal straight |
10 mm OD: BPC1004; 12 mm OD: BPC1204 |
| BPOC metal round straight |
12 mm OD: BPOC1204 |
| BKC compression fitting |
10 × 6.5 mm OD × ID: BKC1065-04,BKC1065-04-S; 10 × 7.5 or 8 mm OD × ID: BKC1075-04,BKC1075-04-S; 12 × 8 mm OD × ID: BKC1208-04,BKC1208-04-S; 12 × 9 or 10 mm OD × ID: BKC1209-04,BKC1209-04-S |
| BB male–male adapter |
other end male PT1/4: BB0204,BB0204-S; other end male PT3/8: BB0304,BB0304-S; other end male PT1/2: BB0404,BB0404-S |
| BD male–female adapter |
other end female PT1/8: BD0104,BD0104-S; other end female PT1/4: BD0204,BD0204-S; other end female PT3/8: BD0304,BD0304-S |
| BZ unused auxiliary plug |
BZ04,BZ04-S |
| BSL valve-exhaust silencer |
BSL04,BSL04-S |
| BSLM miniature valve-exhaust silencer |
BSLM04,BSLM04-S |
| BESL adjustable valve-exhaust silencer |
BESL04,BESL04-S |
| PAL plastic valve-exhaust silencer |
PAL04,PAL04D |
| PSL elbow flow control |
8 mm OD: PSL804A,PSL804AD,PSL804B,PSL804BD,PSL804A-S,PSL804AD-S,PSL804B-S,PSL804BD-S; 10 mm OD: PSL1004A,PSL1004AD,PSL1004B,PSL1004BD,PSL1004A-S,PSL1004AD-S,PSL1004B-S,PSL1004BD-S; 12 mm OD: PSL1204A,PSL1204AD,PSL1204B,PSL1204BD,PSL1204A-S,PSL1204AD-S,PSL1204B-S,PSL1204BD-S |
| PSS universal flow control |
12 mm OD: PSS1204A,PSS1204AD,PSS1204B,PSS1204BD,PSS1204A-S,PSS1204AD-S,PSS1204B-S,PSS1204BD-S |
| PTL push-lock flow control |
8 mm OD: PTL804A,PTL804AD,PTL804B,PTL804BD; 10 mm OD: PTL1004A,PTL1004AD,PTL1004B,PTL1004BD; 12 mm OD: PTL1204A,PTL1204AD,PTL1204B,PTL1204BD |
| PSA tube-to-tube flow control |
6 mm OD: PSA6,PSA6D,PSA6-S,PSA6D-S; 8 mm OD: PSA8,PSA8D,PSA8-S,PSA8D-S; 10 mm OD: PSA10,PSA10D,PSA10-S,PSA10D-S; 12 mm OD: PSA12,PSA12D,PSA12-S,PSA12D-S |
| GPSA tube-to-tube flow control |
6 mm OD: GPSA6,GPSA6D; 8 mm OD: GPSA8,GPSA8D; 10 mm OD: GPSA10,GPSA10D; 12 mm OD: GPSA12,GPSA12D |
| PPA valve-exhaust plug-in silencer |
6 mm stem OD: PPA6; 8 mm stem OD: PPA8; 10 mm stem OD: PPA10; 12 mm stem OD: PPA12 |
| US98A PU tubing |
6 × 4 mm OD × ID: US98A060040100MBU; 8 × 5 mm OD × ID: US98A080050100MBU; 10 × 6.5 mm OD × ID: US98A100065100MBU; 12 × 8 mm OD × ID: US98A120080100MBU |
| UE95A PU tubing |
6 × 4 mm OD × ID: UE95A060040100MBU; 8 × 5 mm OD × ID: UE95A080050100MBU; 10 × 6.5 mm OD × ID: UE95A100065100MBU; 12 × 8 mm OD × ID: UE95A120080100MBU |
| ASC separate inline flow control |
two female PT1/2: ASC30015 |
| GAFR upstream filter/regulator |
female PT1/2: GAFR30015S,GAFR40015S |
Separate options; not an included kit or stock promise. Connect both SAI100 working ports with PT1/2 fittings/correct seals; check insertion depth, tool/rotation clearance, flow and tube loads. PT/G/NPT are not interchangeable. The M20×1.5 rod thread is not an air port.
Use suitable soft nylon/PU; match exact OD and compression-fitting ID. Where offered: D black, blank grey, -M miniature; -S specified stainless-304 parts, not an all-stainless cylinder/circuit. PHF has male RA/extra female RB of PT1/2; connect or permissibly seal RB, not a tube socket. Tees/Y/cross/distributors must not bridge chambers or unrelated controls.
Standard push-in fittings, direct/threadless controls and listed silencers: 0–1 MPa, −20–70 °C. BPC/BPOC: 0–0.9 MPa, 0–150 °C; SAI pressure path 0.15–0.9 MPa. BKC/BB/BD/BZ: 0–1 MPa, 0–150 °C; SAI pressure path 0.15–1 MPa. General cylinder −20–70 °C with 0–150 °C parts gives 0–70 °C or narrower. Apply lower valve/tube/sensor limits; component vacuum data do not rate a vacuum cylinder.
Install threads using the body hex, not locking nut; fully insert tube before tightening. BB/BD are same-standard adapters: BB male–male, BD male–female; table labels the other end. Match gender/size/flow; no cross-thread conversion. BZ closes permitted unused auxiliary ports only, never active cylinder ports.
Cylinder-end A controls thread→tube exhaust (meter-out), with free reverse supply; B controls tube→cylinder supply (meter-in). A is usual for double action; B needs a designed meter-in circuit. Start closed/open slowly. Closed leakage is allowed: not safety shutoffs. PTL caps on 1/2-port variants: adjustment reference: 0.32 N·m, not pipe-thread torque. Do not force caps/end stops. PSA/PSA-S/GPSA are metric tube-to-tube controls without A/B suffixes; match both ODs/check-throttle symbol. GPSA does not mean G thread.
Listed silencers serve separate valve exhaust: match thread/flow/backpressure. Not cylinder-port fittings, inlet filters or shutoffs. BESL adjustment changes backpressure. PPA6/8/10/12 have plain metric stems for matching sockets: POM body/cap, PE filter, 0–1 MPa, −20–70 °C; 25 dB at 0.5 MPa is a catalog test, not a site-noise promise. PPA has no D or thread suffix.
ASC30015: separate two-female-PT1/2-port inline control; needs male fittings. Follow P/A/check-throttle symbol. 0.05–0.95 MPa, −20–70 °C and 40 µm-or-finer filtered air; SAI pressure path 0.15–0.95 MPa before lower limits. Rated flow is not guaranteed cylinder speed.
GAFR30015S,GAFR40015S: separate upstream PT1/2 filter/regulator: 40 µm, PC bowl, differential/manual drain, bracket/round gauge, no reverse-flow valve. Inlet ≤1 MPa, setting 0.15–0.9 MPa, −5–70 °C non-freezing. Respect IN/OUT, flow/pressure loss, condensate, bowl environment and downstream limits. Not cylinder-mounted or a vacuum regulator.
US98A/UE95A examples: blue 100 m coils, not included cut lengths; 1 MPa at 23 °C with temperature derating: US98A −20–70 °C, UE95A −40–70 °C. Match OD/ID, bend radius, routing and flow; thinner low-pressure tubes are not equivalent. Only listed sizing diameters have the reference-speed association.
A 16 × 11 mm reference tube needs separately specified 16 mm endpoint fittings and controls; the listed 12 mm sockets do not form that connection.
Separate Directional-Valve and Tube Examples
4A PT: single control 4A31010, 4A41015; double control 4A32010, 4A42015. 4V PT: single control 4V31010B, 4V41015B; double control 4V32010B, 4V42015B. 5V PT: single control 5V31010B050, 5V41015B050; double control 5V32010B050, 5V42015B050. All listed B versions use DC24V. 4V has DIN entry and internal pilot; 5V has 0.5 m leads (050) and internal pilot. 4A has single/double pneumatic control, external pilot supply and no coil. 4A configurations 30010/40015: single control has one PT1/8 pilot port, double has two; confirm pilot threads on G versions.
30010 (PT: 4A/4V/5V): P 3/8, A/B 3/8, R/S 1/4; 40015 (PT: 4A/4V/5V): P/A/B/R/S 1/2. Ports use the assigned PT/G thread; select endpoints independently. Separate piped valve examples, not direct cylinder fittings or included parts. Operating range: 0.15–0.8 MPa, −20 to 70 °C, 40 µm filtration. Verify flow/load, pilot supply/exhaust backpressure; apply lower component limits.
US98A tubing: 1 MPa at 23 °C, -20 to 70 °C; US98A160110100MBU: 16 × 11 mm, min. bend radius 80 mm; burst reference 3 MPa at 23 °C is not working pressure; reference mass 10.03 kg/100 m. All are blue 100 m coils; derate pressure above 23 °C. Match exact OD, ID, tube compatibility and bend radius; PA6/PA12 sizes 8 × 5 and 10 × 6.5 mm are not established here.
M5 and 4M NAMUR have separate valve interfaces, not direct SAI mounts. No unverified direct adapter or complete kit is specified.
The 16 × 11 mm tube is documented; a complete 16 mm fitting/control path is unestablished. Do not substitute smaller fittings or invent tube codes.
Circuit-Sizing Reference
| Theoretical reference speed |
Flow-area and tube reference |
| 300 mm/s |
12.3 mm² effective flow area; 16 × 11 mm tube OD × ID |
| 400 mm/s |
16.4 mm² effective flow area; 16 × 11 mm tube OD × ID |
| 500 mm/s |
20.4 mm² effective flow area; 16 × 11 mm tube OD × ID |
| 600 mm/s |
24.5 mm² effective flow area; 16 × 11 mm tube OD × ID |
| 700 mm/s |
28.6 mm² effective flow area; 16 × 11 mm tube OD × ID |
| 800 mm/s |
32.7 mm² effective flow area; 16 × 11 mm tube OD × ID |
Generic bore references, not measured SAI speeds. Flow area is not piston area or rated valve flow. Pressure/tube length/load are unspecified; the 0.5 MPa force example does not apply. Obey the 30–800 mm/s cylinder limit, actual valve/fitting/tube flow, cushions and exhaust backpressure. Similar nominal sizes do not make metric tubes fit inch sockets.