Description

Specifications: DPHP3-10050T is an AirTAC DPH digital pressure sensor for non-corrosive gas, with PNP switching outputs, 4–20 mA analog current output, −100 to 1,000 kPa measurement range and a 5 m lead. It uses the terminal-entry configuration and NPT1/8 external with #10-32 UNF female thread.

Product Catalog

Download Airtac Product Catalog (PDF)

For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

Model Code Explained

Code Meaning for This Product
DPH Digital display pressure sensor with analog output
P3 PNP transistor outputs plus 4–20 mA analog current
Blank electrical-entry code Terminal entry
10 −100 to 1,000 kPa measurement range
050 5 m lead
T NPT1/8 external with #10-32 UNF female thread

Technical Specifications

Parameter Details
Working fluid Non-corrosive gas
Supply 12–24 V DC ±10%; ripple peak-to-peak <10%
Current consumption 40 mA or less
Measurement range −100 to 1,000 kPa
Withstand-pressure range as printed −15 to 175 psi
Measurement error ±2% F.S. and ±1 digit at 25 ±3 °C
Repeatability ±0.2% F.S.
Temperature error ±3% F.S.; reference 25 °C, range 0–50 °C
Measured-value display 4 digits
Set-value display 3.5 digits
Display Two-row LCD with analog indication, red/green two-color display
Digital outputs PNP transistor; maximum applied voltage 30 V, maximum 100 mA; residual voltage <2 V
Selected analog output 4–20 mA analog current ±3% F.S.
Analog load 50–260 Ω load impedance
Available pressure units MPa, kPa, kgf/cm², bar, psi, cmHg, inHg
Operating temperature 0–50 °C
Storage temperature −20 to 65 °C
Humidity 35–80% RH, no condensation
Vibration resistance 10–500 Hz, 10 mm amplitude, 2 hours in each X/Y/Z direction, as printed
Impact resistance Maximum 100 m/s²; 3 times in each X/Y/Z direction
Electrical-entry protection The catalog assigns IP63 specifically to B grommet entry; no terminal-entry IP rating is assigned here

Dimensions and Mounting

Dimensions below are in millimeters unless another unit is shown. Local callouts retain the view and datum in the catalog; they are not interchangeable overall dimensions.

Parameter Details
Front envelope 30 × 30 mm
Body depth 28.6 mm
Depth to pressure-port shoulder 35.6 mm
Overall depth including process connection 47.6 mm
Port-root local length 7 mm
Rear mounting holes 2 × M3
Rear mounting-hole layout 20 × 20 mm
Pressure connection NPT1/8 external with #10-32 UNF female thread

For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

Electrical Connections

Parameter Details
Pin 1 / brown DC positive supply
Pin 2 / black OUT1 switching output
Pin 3 / white OUT2 switching output
Pin 4 / orange Selected analog output or zero-shift input
Pin 5 / blue DC negative / 0 V
Switching loads Between black/white output and DC negative for PNP
Analog load Between orange analog output and DC negative, within the selected output load specification
Zero-shift input The illustrated input switch connects orange to DC negative when the zero-shift function is selected

Do not directly connect the analog orange conductor to 0 V or an externally imposed bias voltage without its required load, and do not leave the analog load floating. Analog output and zero-shift input share the orange connection and are selected by the instrument mode.

Display and Controls

Parameter Details
A / up button Increase a selected value
B / SET Select and confirm the menu
C / down button Decrease a selected value
D Measured-pressure display
E Set-pressure display
F / G OUT1 / OUT2 indicators
H Power / signal connection
I Pressure input
  • From measurement mode, hold SET for two seconds to switch to the basic setting interface; the diagram uses SET for two seconds to return.
  • Hold SET for four seconds to show zero-shift pressure; use the indicated SET operation to return.
  • In the measurement-setting interface, press SET to move between parameters and use the up/down buttons to set the values.

Operating Modes

Parameter Details
Basic Each output uses its selected pressure setpoint (1P/2P) and the fixed hysteresis shown in the timing chart.
Hysteresis Separate upper and lower thresholds 1H/1L and 2H/2L; the output changes state at the corresponding threshold.
Window comparator In the illustrated normal output mode, the output is ON between the lower and upper thresholds and OFF outside the window; hysteresis applies at both boundaries.
Suction check Output 1 checks suction pressure, including the zero-shift reference where selected; output 2 detects vacuum-plate break. The zero-shift operation follows the selected TS delay. Intermediate mode derives 1P from the average of two entered measured values.
Leakage Output 1 checks fill pressure between 1H and 1L. Output 2 evaluates leakage relative to the zero-shift reference and its 2P leak setting; the zero-shift input is required for that leak judgment.

For basic/window modes, the timing diagram gives fixed hysteresis references of 0.5 kPa for the 100 kPa range and 2 kPa for the 1,000 kPa range. N.O./N.C. settings can reverse the resulting switching logic.

Settings and Functions

Parameter Details
Switching-output polarity OUT1 and OUT2 each offer N.O./N.C. selections in the menu
Output delay: specification page 1 2, 20, 100, 500, 1,000 and 2,000 ms
Output delay: menu diagram page 4 2, 20, 50, 100, 250, 500 and 1,000 ms, plus 2.5 s and 5 s
Delay-version note The two lists in this PDF differ. Select only a delay actually available in the supplied instrument; do not assume all listed values are present in one firmware version.
Display color Red on output / green without output; green on output / red without output; always red; always green
Secondary display Setting, peak hold, bottom hold, or alternating peak/bottom
Display refresh selections 100, 250, 500 or 1,000 ms
Power saving ON/OFF selection
Original settings Reset / retain selection
Analog / zero-shift mode The menu assigns the orange conductor to analog output or zero-shift input. These are operating selections, not simultaneous functions of that wire.
  • Key lock: press up and SET together, release when LCK ON appears. Unlock with down and SET together, releasing when LCK OFF appears.
  • Zero clear: press up and down together to reset the displayed value to zero.
  • The selected analog output changes linearly from 4 mA at −100 kPa to 20 mA at 1,000 kPa, as illustrated.
  • Read the timing diagrams and available settings for the supplied version before using leakage or suction-check outputs in machine logic.

Separately Ordered Mounting Accessories

Parameter Details
F-DPSEB Panel adapter and front protective cover for terminal and B grommet types; 31 mm square panel-frame opening, +0 / −0.5 mm
F-DPSLB Rear mounting bracket, shown with this housing; 29.6 mm width, 24 mm upright, thickness 1.6 mm and 2 × Ø3.2 rear holes
F-DPSDEB The accessory page separately lists a bottom-ported housing panel adapter with 35.5 ±0.3 mm opening and 1–5 mm panel thickness. It is not the panel adapter specified for this terminal/B housing.
Supply scope The sensor model code does not include the separately ordered panel adapter or bracket. No extra kit count is inferred from the illustration.

Installation and Use

  • Do not drop the sensor or subject it to excessive impact.
  • The cable tensile-strength figure is 60 N; avoid applying excessive pull to the cable.
  • Do not exceed 7 N·m when screwing in the pressure connection. This is a piping limit, not the M3 bracket-screw torque.
  • Use non-corrosive gas within the rated pressure range; do not use corrosive or flammable gases or liquids.
  • Switch off the power before connecting or disconnecting wires.
  • Avoid environments where oil or solvent liquid splashes onto the unit.
  • Keep sensor wiring separate from high-voltage and power wiring; do not share the same conduit.

Estimated Weight

Estimated product weight: 142 g. This is a dimensional or analogous-component planning estimate, not an AirTAC published weight, an individual weighing or a packed shipping weight. Actual product weight can differ.

Catalog Basis

Linked DPH catalog, PDF pages 1–7 / printed pages 280–286. The pressure and analog type follow the current order code. Specification-page and menu-page delay lists are identified separately above because they differ within the supplied catalog.

Product form

Specifications: DPHP3-10050T is an AirTAC DPH digital pressure sensor for non-corrosive gas, with PNP switching outputs, 4–20 mA analog current... Read more

SKU: DPHP3-10050T

$118.09 Incl. VAT

    Guaranteed secure & safe checkout.

    Ach Direct DebitAmazon American Express Apple Pay BizumDiners ClubDiscoverGoogle Pay Mastercard MB WAY PayPalSatispayShop Pay USDC Visa

    Bank transfer also available. Payment options may vary by location and device.

    Shipping, returns & order help

    Free shipping on orders US$30+ under 2 kg

    Import duties & taxes included on all orders

    Download: 3D model selection.
    Shipping & delivery times

    In-stock items: processed and shipped within 1–3 business days. Custom-made items: G/NPT threads and non-standard specifications require 7–15 business days of factory production before shipping.

    Standard international delivery typically takes 7–13 business days after dispatch, depending on customs clearance and the local delivery network. Processing or production time is additional. Next-day and overnight delivery are not available.

    Most products ship from our manufacturing centers in Asia, then transfer to a local carrier after customs clearance.

    Read our shipping policy
    Shipping costs & import taxes

    Free shipping: orders of US$30 or more weighing under 2 kg. Import duties and taxes are included on all orders.

    If an overweight shipping surcharge applies after packing, we pause shipment and email you the amount for approval before dispatch. This is a transport charge, not an import tax. If you do not reply within 7 days, the order is canceled and fully refunded.

    Shipping charges and tax details
    Model selection & custom orders

    Please check the full model number, dimensions, thread type, stroke and voltage where applicable before ordering. If you are unsure, email airtacs@airtacs.com with the model number and required specifications.

    Custom-made products, including G/NPT thread specifications and custom-built parts, are non-returnable and non-refundable under our refund policy.

    Read the refund policy before ordering
    Tracking & delivery support

    Use the tracking link in your shipping confirmation email. For YunExpress shipments, enter your YT tracking number at Yuntrack to view the journey and local delivery details.

    Provide a complete physical delivery address and reachable contact details. P.O. boxes and virtual mail-forwarding addresses are not accepted.

    If delivery fails, contact the local carrier and email airtacs@airtacs.com with your order and tracking numbers. For failures caused by an incorrect/incomplete address or an unreachable recipient, return to the local warehouse typically takes 7–30 business days. Redelivery requires an additional shipping fee; cancellation after failed delivery is subject to deductions for original shipping and carrier return fees.

    Delivery issue policy
    Returns & product issues

    Eligible returns are accepted within 7 days of delivery. Items must be unused, uninstalled and in their original factory packaging. Contact airtacs@airtacs.com for a Return Authorization (RA) number before returning anything.

    Ordered the wrong model or changed your mind? You pay return shipping, original shipping is non-refundable, and a 50% restocking fee is deducted from the actual price paid for the returned product.

    Defective, damaged or incorrect item? We provide a replacement and cover return shipping; no restocking fee applies. Custom-made items are excluded from standard returns. These terms are subject to applicable law and do not limit your statutory rights.

    Read the full refund policy
    Bank transfers & invoices

    Bank transfer: Select bank transfer at checkout and submit your order. The bank account details and payment instructions will then be displayed.

    Invoices: Invoices are available only after an order is placed. We are a US-based company and provide a standard commercial invoice, not an EU VAT tax invoice. If your company requires an EU VAT invoice, please confirm your requirements with us before ordering.

    For payment or invoice questions, email airtacs@airtacs.com with your order number.

    Description

    Specifications: DPHP3-10050T is an AirTAC DPH digital pressure sensor for non-corrosive gas, with PNP switching outputs, 4–20 mA analog current output, −100 to 1,000 kPa measurement range and a 5 m lead. It uses the terminal-entry configuration and NPT1/8 external with #10-32 UNF female thread.

    Product Catalog

    Download Airtac Product Catalog (PDF)

    For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

    Model Code Explained

    Code Meaning for This Product
    DPH Digital display pressure sensor with analog output
    P3 PNP transistor outputs plus 4–20 mA analog current
    Blank electrical-entry code Terminal entry
    10 −100 to 1,000 kPa measurement range
    050 5 m lead
    T NPT1/8 external with #10-32 UNF female thread

    Technical Specifications

    Parameter Details
    Working fluid Non-corrosive gas
    Supply 12–24 V DC ±10%; ripple peak-to-peak <10%
    Current consumption 40 mA or less
    Measurement range −100 to 1,000 kPa
    Withstand-pressure range as printed −15 to 175 psi
    Measurement error ±2% F.S. and ±1 digit at 25 ±3 °C
    Repeatability ±0.2% F.S.
    Temperature error ±3% F.S.; reference 25 °C, range 0–50 °C
    Measured-value display 4 digits
    Set-value display 3.5 digits
    Display Two-row LCD with analog indication, red/green two-color display
    Digital outputs PNP transistor; maximum applied voltage 30 V, maximum 100 mA; residual voltage <2 V
    Selected analog output 4–20 mA analog current ±3% F.S.
    Analog load 50–260 Ω load impedance
    Available pressure units MPa, kPa, kgf/cm², bar, psi, cmHg, inHg
    Operating temperature 0–50 °C
    Storage temperature −20 to 65 °C
    Humidity 35–80% RH, no condensation
    Vibration resistance 10–500 Hz, 10 mm amplitude, 2 hours in each X/Y/Z direction, as printed
    Impact resistance Maximum 100 m/s²; 3 times in each X/Y/Z direction
    Electrical-entry protection The catalog assigns IP63 specifically to B grommet entry; no terminal-entry IP rating is assigned here

    Dimensions and Mounting

    Dimensions below are in millimeters unless another unit is shown. Local callouts retain the view and datum in the catalog; they are not interchangeable overall dimensions.

    Parameter Details
    Front envelope 30 × 30 mm
    Body depth 28.6 mm
    Depth to pressure-port shoulder 35.6 mm
    Overall depth including process connection 47.6 mm
    Port-root local length 7 mm
    Rear mounting holes 2 × M3
    Rear mounting-hole layout 20 × 20 mm
    Pressure connection NPT1/8 external with #10-32 UNF female thread

    For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

    Electrical Connections

    Parameter Details
    Pin 1 / brown DC positive supply
    Pin 2 / black OUT1 switching output
    Pin 3 / white OUT2 switching output
    Pin 4 / orange Selected analog output or zero-shift input
    Pin 5 / blue DC negative / 0 V
    Switching loads Between black/white output and DC negative for PNP
    Analog load Between orange analog output and DC negative, within the selected output load specification
    Zero-shift input The illustrated input switch connects orange to DC negative when the zero-shift function is selected

    Do not directly connect the analog orange conductor to 0 V or an externally imposed bias voltage without its required load, and do not leave the analog load floating. Analog output and zero-shift input share the orange connection and are selected by the instrument mode.

    Display and Controls

    Parameter Details
    A / up button Increase a selected value
    B / SET Select and confirm the menu
    C / down button Decrease a selected value
    D Measured-pressure display
    E Set-pressure display
    F / G OUT1 / OUT2 indicators
    H Power / signal connection
    I Pressure input
    • From measurement mode, hold SET for two seconds to switch to the basic setting interface; the diagram uses SET for two seconds to return.
    • Hold SET for four seconds to show zero-shift pressure; use the indicated SET operation to return.
    • In the measurement-setting interface, press SET to move between parameters and use the up/down buttons to set the values.

    Operating Modes

    Parameter Details
    Basic Each output uses its selected pressure setpoint (1P/2P) and the fixed hysteresis shown in the timing chart.
    Hysteresis Separate upper and lower thresholds 1H/1L and 2H/2L; the output changes state at the corresponding threshold.
    Window comparator In the illustrated normal output mode, the output is ON between the lower and upper thresholds and OFF outside the window; hysteresis applies at both boundaries.
    Suction check Output 1 checks suction pressure, including the zero-shift reference where selected; output 2 detects vacuum-plate break. The zero-shift operation follows the selected TS delay. Intermediate mode derives 1P from the average of two entered measured values.
    Leakage Output 1 checks fill pressure between 1H and 1L. Output 2 evaluates leakage relative to the zero-shift reference and its 2P leak setting; the zero-shift input is required for that leak judgment.

    For basic/window modes, the timing diagram gives fixed hysteresis references of 0.5 kPa for the 100 kPa range and 2 kPa for the 1,000 kPa range. N.O./N.C. settings can reverse the resulting switching logic.

    Settings and Functions

    Parameter Details
    Switching-output polarity OUT1 and OUT2 each offer N.O./N.C. selections in the menu
    Output delay: specification page 1 2, 20, 100, 500, 1,000 and 2,000 ms
    Output delay: menu diagram page 4 2, 20, 50, 100, 250, 500 and 1,000 ms, plus 2.5 s and 5 s
    Delay-version note The two lists in this PDF differ. Select only a delay actually available in the supplied instrument; do not assume all listed values are present in one firmware version.
    Display color Red on output / green without output; green on output / red without output; always red; always green
    Secondary display Setting, peak hold, bottom hold, or alternating peak/bottom
    Display refresh selections 100, 250, 500 or 1,000 ms
    Power saving ON/OFF selection
    Original settings Reset / retain selection
    Analog / zero-shift mode The menu assigns the orange conductor to analog output or zero-shift input. These are operating selections, not simultaneous functions of that wire.
    • Key lock: press up and SET together, release when LCK ON appears. Unlock with down and SET together, releasing when LCK OFF appears.
    • Zero clear: press up and down together to reset the displayed value to zero.
    • The selected analog output changes linearly from 4 mA at −100 kPa to 20 mA at 1,000 kPa, as illustrated.
    • Read the timing diagrams and available settings for the supplied version before using leakage or suction-check outputs in machine logic.

    Separately Ordered Mounting Accessories

    Parameter Details
    F-DPSEB Panel adapter and front protective cover for terminal and B grommet types; 31 mm square panel-frame opening, +0 / −0.5 mm
    F-DPSLB Rear mounting bracket, shown with this housing; 29.6 mm width, 24 mm upright, thickness 1.6 mm and 2 × Ø3.2 rear holes
    F-DPSDEB The accessory page separately lists a bottom-ported housing panel adapter with 35.5 ±0.3 mm opening and 1–5 mm panel thickness. It is not the panel adapter specified for this terminal/B housing.
    Supply scope The sensor model code does not include the separately ordered panel adapter or bracket. No extra kit count is inferred from the illustration.

    Installation and Use

    • Do not drop the sensor or subject it to excessive impact.
    • The cable tensile-strength figure is 60 N; avoid applying excessive pull to the cable.
    • Do not exceed 7 N·m when screwing in the pressure connection. This is a piping limit, not the M3 bracket-screw torque.
    • Use non-corrosive gas within the rated pressure range; do not use corrosive or flammable gases or liquids.
    • Switch off the power before connecting or disconnecting wires.
    • Avoid environments where oil or solvent liquid splashes onto the unit.
    • Keep sensor wiring separate from high-voltage and power wiring; do not share the same conduit.

    Estimated Weight

    Estimated product weight: 142 g. This is a dimensional or analogous-component planning estimate, not an AirTAC published weight, an individual weighing or a packed shipping weight. Actual product weight can differ.

    Catalog Basis

    Linked DPH catalog, PDF pages 1–7 / printed pages 280–286. The pressure and analog type follow the current order code. Specification-page and menu-page delay lists are identified separately above because they differ within the supplied catalog.

    Recently viewed products

      Footer image

      © 2026 Airtac, Powered by Shopify

      • US (USD $) US (USD $)
      • Ach Direct Debit
      • Amazon
      • American Express
      • Apple Pay
      • Bizum
      • Diners Club
      • Discover
      • Google Pay
      • Mastercard
      • MB WAY
      • PayPal
      • Satispay
      • Shop Pay
      • USDC
      • Visa