Specifications: 6D1H12FJ06 is a 12-station 6D100 side-port manifold base without solenoid valves, with 25-pin D-sub wiring and 6 mm outside-diameter tube connections at ports A and B.
Product Catalog
Download Airtac Product Catalog (PDF)
English catalog: 6D and 6DW valves, manifolds, communication modules and listed accessories; 18 pages (printed pages 49–66).
Download Chinese Catalog and Specification Update (PDF)
Chinese reference: 6DM, 6D and 6DW, including 15-pin 6DM ordering, dimensions and wiring; 22 PDF pages. Pages 1–18 cover the main series, pages 19–21 cover derivative valves, and page 22 contains the official temperature correction.
For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.
Series Comparison
Compared with the SMC SY series, the AirTAC 6D series is a functional alternative.
Model Code Explained
| Code |
Meaning |
| 6D1H |
6D100 side-port integrated manifold family |
| 12F |
12 manifold stations |
| J06 |
Ports A/B: quick tube fittings for 6 mm tube outside diameter |
Configuration and compatible parts
| Parameter |
Specification |
| Manifold stations |
12 |
| Single-solenoid 5/2 valves |
No quantity specified |
| Double-solenoid 5/2 valves |
No quantity specified |
| 5/3 closed-center valves |
No quantity specified |
| 5/3 exhaust-center valves |
No quantity specified |
| 5/3 pressure-center valves |
No quantity specified |
| Communication module |
Not specified |
| Matching replaceable valve family |
6D100. Separately ordered valve options: DC24V: 6D110B (single-solenoid 5/2); 6D120B (double-solenoid 5/2); 6D130CB (5/3 closed center); 6D130EB (5/3 exhaust center); 6D130PB (5/3 pressure center); DC12V: 6D110F (single-solenoid 5/2); 6D120F (double-solenoid 5/2); 6D130CF (5/3 closed center); 6D130EF (5/3 exhaust center); 6D130PF (5/3 pressure center). This empty base includes no valves. Select coil voltage, function and quantity within the manifold's station and output limits before ordering. |
| Matching provisional block |
P-6D100M-R2 |
This is a manifold base. Coil power, valve switching response and valve-flow curves describe compatible valves and are not active functions of the bare base.
A station is a mounting position. It is not an extra solenoid valve. Any position without a valve must be fitted with the specified provisional block before the bank is operated.
The source allows single-solenoid, double-solenoid and 5/3-way valves within the bank limits; variants not encoded in this model are selection alternatives, not additional items included with this product.
Pneumatic specifications
| Parameter |
Specification |
| Working medium |
Air filtered through a 40 μm filter |
| Valve actuation |
Pilot operated |
| Operating pressure: 5/2 and other non-5/3 types |
0.15–0.8 MPa (21–114 psi) |
| Operating pressure: 5/3 types |
0.2–0.8 MPa (29–114 psi) |
| Proof pressure |
1.2 MPa (175 psi) |
| Pneumatic operating temperature |
−10 to 50°C; subject to the official correction notice |
| Supply and exhaust |
Centralized |
| A/B connection for this model |
6 mm outside-diameter quick tube fittings |
| P/R connection |
10 mm outside-diameter quick tube fittings |
| Series station range |
3–21 |
| Electrical connection |
25-pin D-sub |
These are the applicable family operating limits. A connected bank containing different valve functions must satisfy the operating-pressure requirement of every installed valve.
The official 2025 catalog update comparison, page 1, explicitly changes this family from −20–70°C to −10–50°C. The corrected −10–50°C range is used here; the separately downloaded Chinese series sheet still displays the earlier range.
Compatible valve electrical reference
| Parameter |
Specification |
| Available valve coil voltages |
DC24V (B) or DC12V (F), ±10% |
| Power per coil |
0.7 W |
| Insulation / protection |
Class F / dustproof |
| Valve activating time |
0.05 s or less |
Solenoid valves and their coils are not included by this no-valve manifold code. Select the required valve model and coil voltage separately.
Installation dimensions
| Parameter |
Specification |
| Drawing A: station-array span |
192 mm |
| Drawing B |
252.5 mm |
| Drawing C: longitudinal outer span |
265.5 mm |
| Station pitch |
16 mm |
| End-view outer horizontal callout |
70 mm |
| End-view inner horizontal callout |
59.5 mm |
| End-view offset callouts |
15 mm; 10 mm |
| Lower horizontal callout |
51.5 mm |
| End-view vertical callouts |
39 mm; 36 mm |
| D-sub connector vertical callout |
47 mm |
| Outer connector-side vertical callout |
63 mm |
| Plan-view outer transverse callout |
105 mm |
| Plan-view inner transverse callout |
91 mm |
| Right-side vertical reference callouts |
31 mm; 23 mm |
| Right-end longitudinal reference callout |
45.5 mm |
| Round mounting openings |
2 × diameter 5.5 mm |
| Slotted mounting openings |
2 × 6.5 × 5.5 mm |
Dimensions are in millimetres. Drawing-letter values and unlettered callouts follow the standard D-sub 6D100 drawing in the Chinese catalog, PDF page 7 (printed page 59). Use its drawing views to locate the features.
The catalog illustrates the manifold with valves. These drawing callouts are the series installation reference; they do not establish the height or weight of an empty, unpopulated base by itself.
Station capacity and wiring
| Parameter |
Specification |
| D-sub connector |
25 pins |
| COM pin |
13 |
| Double-coil-capable positions |
First 12 stations from the D-sub end |
| Maximum double-solenoid/5/3 valve total for this station count |
12 |
| Maximum mounted valve total |
12 |
| Valve installation direction |
Start at the D-sub end |
| Standard valve installation order |
5/3 closed center → 5/3 exhaust center → 5/3 pressure center → double-solenoid 5/2 → single-solenoid 5/2 |
| Negative COM circuit |
COM negative; controlled signals positive |
| Positive COM circuit |
COM positive; controlled signals negative |
| COM conductor |
The source requires a conductor gauge no greater than 22 AWG |
For a single-solenoid valve, its A signal position is unused. The A/B symbols in the electrical pin table identify coil signals, not the pneumatic A/B tube ports.
The pin assignments below describe the manifold connector for this station range. A listed control signal does not add a valve to the supplied configuration.
D-sub pin assignment
| Parameter |
Specification |
| D-sub pin 1 |
1B: station 1, coil B |
| D-sub pin 2 |
2B: station 2, coil B |
| D-sub pin 3 |
3B: station 3, coil B |
| D-sub pin 4 |
4B: station 4, coil B |
| D-sub pin 5 |
5B: station 5, coil B |
| D-sub pin 6 |
6B: station 6, coil B |
| D-sub pin 7 |
7B: station 7, coil B |
| D-sub pin 8 |
8B: station 8, coil B |
| D-sub pin 9 |
9B: station 9, coil B |
| D-sub pin 10 |
10B: station 10, coil B |
| D-sub pin 11 |
11B: station 11, coil B |
| D-sub pin 12 |
12B: station 12, coil B |
| D-sub pin 13 |
COM |
| D-sub pin 14 |
1A: station 1, coil A |
| D-sub pin 15 |
2A: station 2, coil A |
| D-sub pin 16 |
3A: station 3, coil A |
| D-sub pin 17 |
4A: station 4, coil A |
| D-sub pin 18 |
5A: station 5, coil A |
| D-sub pin 19 |
6A: station 6, coil A |
| D-sub pin 20 |
7A: station 7, coil A |
| D-sub pin 21 |
8A: station 8, coil A |
| D-sub pin 22 |
9A: station 9, coil A |
| D-sub pin 23 |
10A: station 10, coil A |
| D-sub pin 24 |
11A: station 11, coil A |
| D-sub pin 25 |
12A: station 12, coil A |
Mounting, commissioning and accessories
| Parameter |
Specification |
| Mounting methods |
Direct panel mounting or DIN rail |
| Direct mounting |
Four counterbored mounting positions |
| DIN mounting |
Use DIN-standard rail and secure the bank with the stopper screw |
| D-sub orientation |
Horizontal or vertical orientation may be selected as shown in the installation drawing |
| Manual override |
Provided on compatible valves for installation and commissioning |
| Manual override tool torque |
0.1 N·m |
| Catalog-listed silencer/plug provision |
2 tube-insert silencers and 1 tube plug |
| Vacant-station block |
P-6D100M-R2; source states that its screws are supplied |
| DIN rail reference |
F-DINX140 is the illustrated 140 mm ordering example; choose rail length to suit the installation |
Before using the manual override, make sure it is safe for the connected actuator to move. Use the appropriate screwdriver, press gently and turn as illustrated.
The base supports direct or DIN-rail mounting and mixed 2-position/3-position valves without a separate conversion accessory. This does not imply that separately ordered rail, valves, network cables or other catalog accessories are included.
Published flow-curve reference
| Parameter |
Specification |
| Source curve model |
6D110-08 |
| Horizontal axis |
Flow, 0–1000 L/min |
| Vertical axis |
Operating pressure, 0–0.7 MPa |
| Data origin |
AirTAC laboratory measurements |
The curves are valve-family reference plots. The axis limit is not a rated flow for every bank, every fitting size or every switching configuration. The source does not give a separate flow rating for this exact manifold assembly.
Series options shown in the linked English catalog
Individual-inlet E, individual-exhaust R and external-pilot W valve groups are separately ordered derivatives. The source limits each of these group specifications to at most two types and places it after the standard valves of the same control type. They are not selected by this model.
The linked English catalog also shows two-valves-in-one 3/2-way NC-NC and NO-NO derivatives. These are placed after standard double-solenoid 5/2 valves. They are selection references only; this model has no such quantity suffix.
Construction and source scope
The documented assembly consists of the manifold/base, electrical transfer block and D-sub connection, with valves and an optional communication module as encoded. The source does not publish a numbered internal-materials bill of materials or a net-weight table for this exact assembly.
Chinese 6DM/6D/6DW catalog information is used for the series codes and dimensions. The linked English edition is a reference for the published English drawings and instructions.
Dimensions and Mounting Drawings
For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.