Airtac 6D series: valve manifold base - 6D1H12FJ06

Photos are for reference only. Not all models have pictures.

Description

Specifications: 6D1H12FJ06 is a 12-station 6D100 side-port manifold base without solenoid valves, with 25-pin D-sub wiring and 6 mm outside-diameter tube connections at ports A and B.

Product Catalog

Download Airtac Product Catalog (PDF)

English catalog: 6D and 6DW valves, manifolds, communication modules and listed accessories; 18 pages (printed pages 49–66).

Download Chinese Catalog and Specification Update (PDF)

Chinese reference: 6DM, 6D and 6DW, including 15-pin 6DM ordering, dimensions and wiring; 22 PDF pages. Pages 1–18 cover the main series, pages 19–21 cover derivative valves, and page 22 contains the official temperature correction.

For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

Series Comparison

Compared with the SMC SY series, the AirTAC 6D series is a functional alternative.

Model Code Explained

Code Meaning
6D1H 6D100 side-port integrated manifold family
12F 12 manifold stations
J06 Ports A/B: quick tube fittings for 6 mm tube outside diameter

Configuration and compatible parts

Parameter Specification
Manifold stations 12
Single-solenoid 5/2 valves No quantity specified
Double-solenoid 5/2 valves No quantity specified
5/3 closed-center valves No quantity specified
5/3 exhaust-center valves No quantity specified
5/3 pressure-center valves No quantity specified
Communication module Not specified
Matching replaceable valve family 6D100. Separately ordered valve options: DC24V: 6D110B (single-solenoid 5/2); 6D120B (double-solenoid 5/2); 6D130CB (5/3 closed center); 6D130EB (5/3 exhaust center); 6D130PB (5/3 pressure center); DC12V: 6D110F (single-solenoid 5/2); 6D120F (double-solenoid 5/2); 6D130CF (5/3 closed center); 6D130EF (5/3 exhaust center); 6D130PF (5/3 pressure center). This empty base includes no valves. Select coil voltage, function and quantity within the manifold's station and output limits before ordering.
Matching provisional block P-6D100M-R2

This is a manifold base. Coil power, valve switching response and valve-flow curves describe compatible valves and are not active functions of the bare base.

A station is a mounting position. It is not an extra solenoid valve. Any position without a valve must be fitted with the specified provisional block before the bank is operated.

The source allows single-solenoid, double-solenoid and 5/3-way valves within the bank limits; variants not encoded in this model are selection alternatives, not additional items included with this product.

Pneumatic specifications

Parameter Specification
Working medium Air filtered through a 40 μm filter
Valve actuation Pilot operated
Operating pressure: 5/2 and other non-5/3 types 0.15–0.8 MPa (21–114 psi)
Operating pressure: 5/3 types 0.2–0.8 MPa (29–114 psi)
Proof pressure 1.2 MPa (175 psi)
Pneumatic operating temperature −10 to 50°C; subject to the official correction notice
Supply and exhaust Centralized
A/B connection for this model 6 mm outside-diameter quick tube fittings
P/R connection 10 mm outside-diameter quick tube fittings
Series station range 3–21
Electrical connection 25-pin D-sub

These are the applicable family operating limits. A connected bank containing different valve functions must satisfy the operating-pressure requirement of every installed valve.

The official 2025 catalog update comparison, page 1, explicitly changes this family from −20–70°C to −10–50°C. The corrected −10–50°C range is used here; the separately downloaded Chinese series sheet still displays the earlier range.

Compatible valve electrical reference

Parameter Specification
Available valve coil voltages DC24V (B) or DC12V (F), ±10%
Power per coil 0.7 W
Insulation / protection Class F / dustproof
Valve activating time 0.05 s or less

Solenoid valves and their coils are not included by this no-valve manifold code. Select the required valve model and coil voltage separately.

Installation dimensions

Parameter Specification
Drawing A: station-array span 192 mm
Drawing B 252.5 mm
Drawing C: longitudinal outer span 265.5 mm
Station pitch 16 mm
End-view outer horizontal callout 70 mm
End-view inner horizontal callout 59.5 mm
End-view offset callouts 15 mm; 10 mm
Lower horizontal callout 51.5 mm
End-view vertical callouts 39 mm; 36 mm
D-sub connector vertical callout 47 mm
Outer connector-side vertical callout 63 mm
Plan-view outer transverse callout 105 mm
Plan-view inner transverse callout 91 mm
Right-side vertical reference callouts 31 mm; 23 mm
Right-end longitudinal reference callout 45.5 mm
Round mounting openings 2 × diameter 5.5 mm
Slotted mounting openings 2 × 6.5 × 5.5 mm

Dimensions are in millimetres. Drawing-letter values and unlettered callouts follow the standard D-sub 6D100 drawing in the Chinese catalog, PDF page 7 (printed page 59). Use its drawing views to locate the features.

The catalog illustrates the manifold with valves. These drawing callouts are the series installation reference; they do not establish the height or weight of an empty, unpopulated base by itself.

Station capacity and wiring

Parameter Specification
D-sub connector 25 pins
COM pin 13
Double-coil-capable positions First 12 stations from the D-sub end
Maximum double-solenoid/5/3 valve total for this station count 12
Maximum mounted valve total 12
Valve installation direction Start at the D-sub end
Standard valve installation order 5/3 closed center → 5/3 exhaust center → 5/3 pressure center → double-solenoid 5/2 → single-solenoid 5/2
Negative COM circuit COM negative; controlled signals positive
Positive COM circuit COM positive; controlled signals negative
COM conductor The source requires a conductor gauge no greater than 22 AWG

For a single-solenoid valve, its A signal position is unused. The A/B symbols in the electrical pin table identify coil signals, not the pneumatic A/B tube ports.

The pin assignments below describe the manifold connector for this station range. A listed control signal does not add a valve to the supplied configuration.

D-sub pin assignment

Parameter Specification
D-sub pin 1 1B: station 1, coil B
D-sub pin 2 2B: station 2, coil B
D-sub pin 3 3B: station 3, coil B
D-sub pin 4 4B: station 4, coil B
D-sub pin 5 5B: station 5, coil B
D-sub pin 6 6B: station 6, coil B
D-sub pin 7 7B: station 7, coil B
D-sub pin 8 8B: station 8, coil B
D-sub pin 9 9B: station 9, coil B
D-sub pin 10 10B: station 10, coil B
D-sub pin 11 11B: station 11, coil B
D-sub pin 12 12B: station 12, coil B
D-sub pin 13 COM
D-sub pin 14 1A: station 1, coil A
D-sub pin 15 2A: station 2, coil A
D-sub pin 16 3A: station 3, coil A
D-sub pin 17 4A: station 4, coil A
D-sub pin 18 5A: station 5, coil A
D-sub pin 19 6A: station 6, coil A
D-sub pin 20 7A: station 7, coil A
D-sub pin 21 8A: station 8, coil A
D-sub pin 22 9A: station 9, coil A
D-sub pin 23 10A: station 10, coil A
D-sub pin 24 11A: station 11, coil A
D-sub pin 25 12A: station 12, coil A

Mounting, commissioning and accessories

Parameter Specification
Mounting methods Direct panel mounting or DIN rail
Direct mounting Four counterbored mounting positions
DIN mounting Use DIN-standard rail and secure the bank with the stopper screw
D-sub orientation Horizontal or vertical orientation may be selected as shown in the installation drawing
Manual override Provided on compatible valves for installation and commissioning
Manual override tool torque 0.1 N·m
Catalog-listed silencer/plug provision 2 tube-insert silencers and 1 tube plug
Vacant-station block P-6D100M-R2; source states that its screws are supplied
DIN rail reference F-DINX140 is the illustrated 140 mm ordering example; choose rail length to suit the installation

Before using the manual override, make sure it is safe for the connected actuator to move. Use the appropriate screwdriver, press gently and turn as illustrated.

The base supports direct or DIN-rail mounting and mixed 2-position/3-position valves without a separate conversion accessory. This does not imply that separately ordered rail, valves, network cables or other catalog accessories are included.

Published flow-curve reference

Parameter Specification
Source curve model 6D110-08
Horizontal axis Flow, 0–1000 L/min
Vertical axis Operating pressure, 0–0.7 MPa
Data origin AirTAC laboratory measurements

The curves are valve-family reference plots. The axis limit is not a rated flow for every bank, every fitting size or every switching configuration. The source does not give a separate flow rating for this exact manifold assembly.

Series options shown in the linked English catalog

Individual-inlet E, individual-exhaust R and external-pilot W valve groups are separately ordered derivatives. The source limits each of these group specifications to at most two types and places it after the standard valves of the same control type. They are not selected by this model.

The linked English catalog also shows two-valves-in-one 3/2-way NC-NC and NO-NO derivatives. These are placed after standard double-solenoid 5/2 valves. They are selection references only; this model has no such quantity suffix.

Construction and source scope

The documented assembly consists of the manifold/base, electrical transfer block and D-sub connection, with valves and an optional communication module as encoded. The source does not publish a numbered internal-materials bill of materials or a net-weight table for this exact assembly.

Chinese 6DM/6D/6DW catalog information is used for the series codes and dimensions. The linked English edition is a reference for the published English drawings and instructions.

Dimensions and Mounting Drawings

For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

Reference Weight

Reference weight: approximately 850 g. Empty manifold base only; no valves are added to this estimate. This is a reference estimate, not a manufacturer-published or independently measured net weight. Actual packed shipping weight may differ.

Product form

Specifications: 6D1H12FJ06 is a 12-station 6D100 side-port manifold base without solenoid valves, with 25-pin D-sub wiring and 6 mm outside-diameter... Read more

SKU: 6D1H12FJ06

$213.94 Incl. VAT

    Guaranteed secure & safe checkout.

    Ach Direct DebitAmazon American Express Apple Pay BizumDiners ClubDiscoverGoogle Pay Mastercard MB WAY PayPalSatispayShop Pay USDC Visa

    Bank transfer also available. Payment options may vary by location and device.

    Shipping, returns & order help

    Free shipping on orders US$30+ under 2 kg

    Import duties & taxes included on all orders

    Download: 3D model selection.
    Shipping & delivery times

    In-stock items: processed and shipped within 1–3 business days. Custom-made items: G/NPT threads and non-standard specifications require 7–15 business days of factory production before shipping.

    Standard international delivery typically takes 7–13 business days after dispatch, depending on customs clearance and the local delivery network. Processing or production time is additional. Next-day and overnight delivery are not available.

    Most products ship from our manufacturing centers in Asia, then transfer to a local carrier after customs clearance.

    Read our shipping policy
    Shipping costs & import taxes

    Free shipping: orders of US$30 or more weighing under 2 kg. Import duties and taxes are included on all orders.

    If an overweight shipping surcharge applies after packing, we pause shipment and email you the amount for approval before dispatch. This is a transport charge, not an import tax. If you do not reply within 7 days, the order is canceled and fully refunded.

    Shipping charges and tax details
    Model selection & custom orders

    Please check the full model number, dimensions, thread type, stroke and voltage where applicable before ordering. If you are unsure, email airtacs@airtacs.com with the model number and required specifications.

    Custom-made products, including G/NPT thread specifications and custom-built parts, are non-returnable and non-refundable under our refund policy.

    Read the refund policy before ordering
    Tracking & delivery support

    Use the tracking link in your shipping confirmation email. For YunExpress shipments, enter your YT tracking number at Yuntrack to view the journey and local delivery details.

    Provide a complete physical delivery address and reachable contact details. P.O. boxes and virtual mail-forwarding addresses are not accepted.

    If delivery fails, contact the local carrier and email airtacs@airtacs.com with your order and tracking numbers. For failures caused by an incorrect/incomplete address or an unreachable recipient, return to the local warehouse typically takes 7–30 business days. Redelivery requires an additional shipping fee; cancellation after failed delivery is subject to deductions for original shipping and carrier return fees.

    Delivery issue policy
    Returns & product issues

    Eligible returns are accepted within 7 days of delivery. Items must be unused, uninstalled and in their original factory packaging. Contact airtacs@airtacs.com for a Return Authorization (RA) number before returning anything.

    Ordered the wrong model or changed your mind? You pay return shipping, original shipping is non-refundable, and a 50% restocking fee is deducted from the actual price paid for the returned product.

    Defective, damaged or incorrect item? We provide a replacement and cover return shipping; no restocking fee applies. Custom-made items are excluded from standard returns. These terms are subject to applicable law and do not limit your statutory rights.

    Read the full refund policy
    Bank transfers & invoices

    Bank transfer: Select bank transfer at checkout and submit your order. The bank account details and payment instructions will then be displayed.

    Invoices: Invoices are available only after an order is placed. We are a US-based company and provide a standard commercial invoice, not an EU VAT tax invoice. If your company requires an EU VAT invoice, please confirm your requirements with us before ordering.

    For payment or invoice questions, email airtacs@airtacs.com with your order number.

    Description

    Specifications: 6D1H12FJ06 is a 12-station 6D100 side-port manifold base without solenoid valves, with 25-pin D-sub wiring and 6 mm outside-diameter tube connections at ports A and B.

    Product Catalog

    Download Airtac Product Catalog (PDF)

    English catalog: 6D and 6DW valves, manifolds, communication modules and listed accessories; 18 pages (printed pages 49–66).

    Download Chinese Catalog and Specification Update (PDF)

    Chinese reference: 6DM, 6D and 6DW, including 15-pin 6DM ordering, dimensions and wiring; 22 PDF pages. Pages 1–18 cover the main series, pages 19–21 cover derivative valves, and page 22 contains the official temperature correction.

    For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

    Series Comparison

    Compared with the SMC SY series, the AirTAC 6D series is a functional alternative.

    Model Code Explained

    Code Meaning
    6D1H 6D100 side-port integrated manifold family
    12F 12 manifold stations
    J06 Ports A/B: quick tube fittings for 6 mm tube outside diameter

    Configuration and compatible parts

    Parameter Specification
    Manifold stations 12
    Single-solenoid 5/2 valves No quantity specified
    Double-solenoid 5/2 valves No quantity specified
    5/3 closed-center valves No quantity specified
    5/3 exhaust-center valves No quantity specified
    5/3 pressure-center valves No quantity specified
    Communication module Not specified
    Matching replaceable valve family 6D100. Separately ordered valve options: DC24V: 6D110B (single-solenoid 5/2); 6D120B (double-solenoid 5/2); 6D130CB (5/3 closed center); 6D130EB (5/3 exhaust center); 6D130PB (5/3 pressure center); DC12V: 6D110F (single-solenoid 5/2); 6D120F (double-solenoid 5/2); 6D130CF (5/3 closed center); 6D130EF (5/3 exhaust center); 6D130PF (5/3 pressure center). This empty base includes no valves. Select coil voltage, function and quantity within the manifold's station and output limits before ordering.
    Matching provisional block P-6D100M-R2

    This is a manifold base. Coil power, valve switching response and valve-flow curves describe compatible valves and are not active functions of the bare base.

    A station is a mounting position. It is not an extra solenoid valve. Any position without a valve must be fitted with the specified provisional block before the bank is operated.

    The source allows single-solenoid, double-solenoid and 5/3-way valves within the bank limits; variants not encoded in this model are selection alternatives, not additional items included with this product.

    Pneumatic specifications

    Parameter Specification
    Working medium Air filtered through a 40 μm filter
    Valve actuation Pilot operated
    Operating pressure: 5/2 and other non-5/3 types 0.15–0.8 MPa (21–114 psi)
    Operating pressure: 5/3 types 0.2–0.8 MPa (29–114 psi)
    Proof pressure 1.2 MPa (175 psi)
    Pneumatic operating temperature −10 to 50°C; subject to the official correction notice
    Supply and exhaust Centralized
    A/B connection for this model 6 mm outside-diameter quick tube fittings
    P/R connection 10 mm outside-diameter quick tube fittings
    Series station range 3–21
    Electrical connection 25-pin D-sub

    These are the applicable family operating limits. A connected bank containing different valve functions must satisfy the operating-pressure requirement of every installed valve.

    The official 2025 catalog update comparison, page 1, explicitly changes this family from −20–70°C to −10–50°C. The corrected −10–50°C range is used here; the separately downloaded Chinese series sheet still displays the earlier range.

    Compatible valve electrical reference

    Parameter Specification
    Available valve coil voltages DC24V (B) or DC12V (F), ±10%
    Power per coil 0.7 W
    Insulation / protection Class F / dustproof
    Valve activating time 0.05 s or less

    Solenoid valves and their coils are not included by this no-valve manifold code. Select the required valve model and coil voltage separately.

    Installation dimensions

    Parameter Specification
    Drawing A: station-array span 192 mm
    Drawing B 252.5 mm
    Drawing C: longitudinal outer span 265.5 mm
    Station pitch 16 mm
    End-view outer horizontal callout 70 mm
    End-view inner horizontal callout 59.5 mm
    End-view offset callouts 15 mm; 10 mm
    Lower horizontal callout 51.5 mm
    End-view vertical callouts 39 mm; 36 mm
    D-sub connector vertical callout 47 mm
    Outer connector-side vertical callout 63 mm
    Plan-view outer transverse callout 105 mm
    Plan-view inner transverse callout 91 mm
    Right-side vertical reference callouts 31 mm; 23 mm
    Right-end longitudinal reference callout 45.5 mm
    Round mounting openings 2 × diameter 5.5 mm
    Slotted mounting openings 2 × 6.5 × 5.5 mm

    Dimensions are in millimetres. Drawing-letter values and unlettered callouts follow the standard D-sub 6D100 drawing in the Chinese catalog, PDF page 7 (printed page 59). Use its drawing views to locate the features.

    The catalog illustrates the manifold with valves. These drawing callouts are the series installation reference; they do not establish the height or weight of an empty, unpopulated base by itself.

    Station capacity and wiring

    Parameter Specification
    D-sub connector 25 pins
    COM pin 13
    Double-coil-capable positions First 12 stations from the D-sub end
    Maximum double-solenoid/5/3 valve total for this station count 12
    Maximum mounted valve total 12
    Valve installation direction Start at the D-sub end
    Standard valve installation order 5/3 closed center → 5/3 exhaust center → 5/3 pressure center → double-solenoid 5/2 → single-solenoid 5/2
    Negative COM circuit COM negative; controlled signals positive
    Positive COM circuit COM positive; controlled signals negative
    COM conductor The source requires a conductor gauge no greater than 22 AWG

    For a single-solenoid valve, its A signal position is unused. The A/B symbols in the electrical pin table identify coil signals, not the pneumatic A/B tube ports.

    The pin assignments below describe the manifold connector for this station range. A listed control signal does not add a valve to the supplied configuration.

    D-sub pin assignment

    Parameter Specification
    D-sub pin 1 1B: station 1, coil B
    D-sub pin 2 2B: station 2, coil B
    D-sub pin 3 3B: station 3, coil B
    D-sub pin 4 4B: station 4, coil B
    D-sub pin 5 5B: station 5, coil B
    D-sub pin 6 6B: station 6, coil B
    D-sub pin 7 7B: station 7, coil B
    D-sub pin 8 8B: station 8, coil B
    D-sub pin 9 9B: station 9, coil B
    D-sub pin 10 10B: station 10, coil B
    D-sub pin 11 11B: station 11, coil B
    D-sub pin 12 12B: station 12, coil B
    D-sub pin 13 COM
    D-sub pin 14 1A: station 1, coil A
    D-sub pin 15 2A: station 2, coil A
    D-sub pin 16 3A: station 3, coil A
    D-sub pin 17 4A: station 4, coil A
    D-sub pin 18 5A: station 5, coil A
    D-sub pin 19 6A: station 6, coil A
    D-sub pin 20 7A: station 7, coil A
    D-sub pin 21 8A: station 8, coil A
    D-sub pin 22 9A: station 9, coil A
    D-sub pin 23 10A: station 10, coil A
    D-sub pin 24 11A: station 11, coil A
    D-sub pin 25 12A: station 12, coil A

    Mounting, commissioning and accessories

    Parameter Specification
    Mounting methods Direct panel mounting or DIN rail
    Direct mounting Four counterbored mounting positions
    DIN mounting Use DIN-standard rail and secure the bank with the stopper screw
    D-sub orientation Horizontal or vertical orientation may be selected as shown in the installation drawing
    Manual override Provided on compatible valves for installation and commissioning
    Manual override tool torque 0.1 N·m
    Catalog-listed silencer/plug provision 2 tube-insert silencers and 1 tube plug
    Vacant-station block P-6D100M-R2; source states that its screws are supplied
    DIN rail reference F-DINX140 is the illustrated 140 mm ordering example; choose rail length to suit the installation

    Before using the manual override, make sure it is safe for the connected actuator to move. Use the appropriate screwdriver, press gently and turn as illustrated.

    The base supports direct or DIN-rail mounting and mixed 2-position/3-position valves without a separate conversion accessory. This does not imply that separately ordered rail, valves, network cables or other catalog accessories are included.

    Published flow-curve reference

    Parameter Specification
    Source curve model 6D110-08
    Horizontal axis Flow, 0–1000 L/min
    Vertical axis Operating pressure, 0–0.7 MPa
    Data origin AirTAC laboratory measurements

    The curves are valve-family reference plots. The axis limit is not a rated flow for every bank, every fitting size or every switching configuration. The source does not give a separate flow rating for this exact manifold assembly.

    Series options shown in the linked English catalog

    Individual-inlet E, individual-exhaust R and external-pilot W valve groups are separately ordered derivatives. The source limits each of these group specifications to at most two types and places it after the standard valves of the same control type. They are not selected by this model.

    The linked English catalog also shows two-valves-in-one 3/2-way NC-NC and NO-NO derivatives. These are placed after standard double-solenoid 5/2 valves. They are selection references only; this model has no such quantity suffix.

    Construction and source scope

    The documented assembly consists of the manifold/base, electrical transfer block and D-sub connection, with valves and an optional communication module as encoded. The source does not publish a numbered internal-materials bill of materials or a net-weight table for this exact assembly.

    Chinese 6DM/6D/6DW catalog information is used for the series codes and dimensions. The linked English edition is a reference for the published English drawings and instructions.

    Dimensions and Mounting Drawings

    For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.

    Reference Weight

    Reference weight: approximately 850 g. Empty manifold base only; no valves are added to this estimate. This is a reference estimate, not a manufacturer-published or independently measured net weight. Actual packed shipping weight may differ.

    Recently viewed products

      © 2026 Airtac, Powered by Shopify

      • US (USD $) US (USD $)
      • Ach Direct Debit
      • Amazon
      • American Express
      • Apple Pay
      • Bizum
      • Diners Club
      • Discover
      • Google Pay
      • Mastercard
      • MB WAY
      • PayPal
      • Satispay
      • Shop Pay
      • USDC
      • Visa