{"title":"SR","description":"\u003cbody\u003e\n\n\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cmeta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\"\u003e\n\u003ctitle\u003eRegulator Product Information\u003c\/title\u003e\n\u003cstyle\u003e\n  \/* Overall Style *\/\n  body {\n    font-family: Arial, sans-serif;\n    color: #333;\n    padding: 20px;\n  }\n  .tabs-container {\n    margin: 20px 0;\n    padding: 0 20px;\n    box-sizing: border-box;\n  }\n  .tabs-header h1 {\n    margin: 0 0 10px;\n    font-size: 18px;\n    color: #003366;\n  }\n  .tabs-nav {\n    display: flex;\n    flex-wrap: nowrap;\n    list-style: none;\n    margin: 0;\n    padding: 0;\n    border-bottom: 1px solid #ccc;\n    background-color: #f9f9f9;\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    white-space: nowrap;\n  }\n  .tabs-nav li {\n    flex-shrink: 0;\n    padding: 8px 15px;\n    cursor: pointer;\n    color: #555;\n    font-size: 14px;\n    border-right: 1px solid #eee;\n  }\n  .tabs-nav li:last-child {\n    border-right: none;\n  }\n  .tabs-nav li.active {\n    background-color: #fff;\n    font-weight: bold;\n    color: #000;\n    border-bottom: 2px solid #007ACC;\n  }\n  .tabs-content {\n    padding: 15px 0;\n  }\n  .tab-pane {\n    display: none;\n  }\n  .tab-pane.active {\n    display: block;\n  }\n  h2 {\n    font-size: 20px;\n    color: #000;\n    border-bottom: 2px solid #dbe3f4;\n    padding-bottom: 5px;\n    margin-bottom: 15px;\n  }\n  ul, ol {\n    padding-left: 20px;\n  }\n  li {\n    line-height: 1.8;\n  }\n  table {\n    width: 100%;\n    border-collapse: collapse;\n    margin-top: 10px;\n    font-size: 14px;\n  }\n  th, td {\n    border: 1px solid #ccc;\n    padding: 8px 10px;\n    text-align: center;\n    vertical-align: middle;\n  }\n  th {\n    background-color: #f1f5fb;\n  }\n  \/* Custom style for left-aligning content in the ordering code table *\/\n  .ordering-table td {\n    text-align: left;\n    vertical-align: top;\n  }\n  .ordering-table th, .ordering-table td:first-child {\n    text-align: center;\n  }\n  .ordering-table td ul {\n      padding-left: 15px;\n      margin: 0;\n  }\n  .note {\n    font-size: 12px;\n    color: #555;\n    margin-top: 10px;\n    line-height: 1.6;\n    text-align: left;\n  }\n  @media (max-width: 768px) {\n    table {\n      display: block;\n      overflow-x: auto;\n      -webkit-overflow-scrolling: touch;\n      white-space: nowrap;\n    }\n  }\n\u003c\/style\u003e\n\n\n\n\u003cdiv class=\"tabs-container\"\u003e\n  \u003cdiv class=\"tabs-header\"\u003e\n    \u003ch1\u003eRegulator\u003c\/h1\u003e\n  \u003c\/div\u003e\n  \u003cul id=\"tabsNav\" class=\"tabs-nav\"\u003e\n    \u003cli data-tab=\"pane1\" class=\"active\"\u003eProduct Features\u003c\/li\u003e\n    \u003cli data-tab=\"pane2\"\u003eSpecifications\u003c\/li\u003e\n    \u003cli data-tab=\"pane3\"\u003eProduct Ordering Code\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cdiv class=\"tabs-content\"\u003e\n    \u003cdiv id=\"pane1\" class=\"tab-pane active\"\u003e\n      \u003ch2\u003eProduct Features\u003c\/h2\u003e\n      \u003col\u003e\n          \u003cli\u003eIndependent pipe-mounted regulator, can also be installed with a panel bracket.\u003c\/li\u003e\n          \u003cli\u003eCompact structure, easy to install and use.\u003c\/li\u003e\n          \u003cli\u003eStable pressure regulation with good pressure characteristics.\u003c\/li\u003e\n          \u003cli\u003eIn addition to the standard type, a low-pressure type is available (maximum adjustable pressure 0.4MPa).\u003c\/li\u003e\n      \u003c\/ol\u003e\n    \u003c\/div\u003e\n    \u003cdiv id=\"pane2\" class=\"tab-pane\"\u003e\n      \u003ch2\u003eSpecifications\u003c\/h2\u003e\n      \u003ctable border=\"1\"\u003e\n          \u003cthead\u003e\n              \u003ctr\u003e\n                  \u003cth\u003eModel\u003c\/th\u003e\n                  \u003cth\u003eSR200-06\u003c\/th\u003e\n                  \u003cth\u003eSR200L-06\u003c\/th\u003e\n                  \u003cth\u003eSR200-08\u003c\/th\u003e\n                  \u003cth\u003eSR200L-08\u003c\/th\u003e\n              \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n              \u003ctr\u003e\n                  \u003ctd\u003eWorking Medium\u003c\/td\u003e\n                  \u003ctd colspan=\"4\"\u003eAir\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                  \u003ctd\u003ePort Size [Note 1]\u003c\/td\u003e\n                  \u003ctd colspan=\"2\"\u003ePT1\/8\u003c\/td\u003e\n                  \u003ctd colspan=\"2\"\u003ePT1\/4\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                  \u003ctd\u003ePressure Regulation Range\u003c\/td\u003e\n                  \u003ctd colspan=\"4\"\u003eStandard type: 0.05–0.9MPa (7–130psi); Low pressure type: 0.03–0.4MPa (4–57psi)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                  \u003ctd\u003eMax Operating Pressure\u003c\/td\u003e\n                  \u003ctd colspan=\"4\"\u003e1.0MPa (145Psi)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                  \u003ctd\u003eProof Pressure\u003c\/td\u003e\n                  \u003ctd colspan=\"4\"\u003e1.5MPa (215Psi)\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                  \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n                  \u003ctd colspan=\"4\"\u003e-20–70°C\u003c\/td\u003e\n              \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n      \u003c\/table\u003e\n      \u003cdiv class=\"note\"\u003e\n          \u003cstrong\u003eNote 1:\u003c\/strong\u003e G and NPT thread types are available.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv id=\"pane3\" class=\"tab-pane\"\u003e\n      \u003ch2\u003eProduct Ordering Code\u003c\/h2\u003e\n      \u003ctable class=\"ordering-table\"\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n            \u003cth\u003ePosition\u003c\/th\u003e\n            \u003cth\u003eDescription\u003c\/th\u003e\n            \u003cth\u003eOptions \u0026amp; Values\u003c\/th\u003e\n          \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e1\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003eModel Code\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cul\u003e\u003cli\u003eSR: SR Series Regulator\u003c\/li\u003e\u003c\/ul\u003e\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e2\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003eSeries Code\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cul\u003e\u003cli\u003e200: 200 series\u003c\/li\u003e\u003c\/ul\u003e\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e3\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003ePort Size\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cul\u003e\n\u003cli\u003e06: 1\/8\"\u003c\/li\u003e\n\u003cli\u003e08: 1\/4\"\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e4\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003eModel Type Code\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cul\u003e\n\u003cli\u003eBlank: Standard Type\u003c\/li\u003e\n\u003cli\u003eL: Low Pressure Type\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e5\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003eBracket Code\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cul\u003e\n\u003cli\u003eBlank: With Bracket\u003c\/li\u003e\n\u003cli\u003eJ: Without Bracket\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e6\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003ePressure Gauge Code\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cul\u003e\n\u003cli\u003eBlank: With Pressure Gauge\u003c\/li\u003e\n\u003cli\u003eN: Without Pressure Gauge\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e7\u003c\/td\u003e\n            \u003ctd\u003e\u003cb\u003ePressure Unit\u003c\/b\u003e\u003c\/td\u003e\n            \u003ctd\u003e\u003cul\u003e\n\u003cli\u003e1: MPa\u003c\/li\u003e\n\u003cli\u003e2: psi\u003c\/li\u003e\n\u003cli\u003e3: bar\u003c\/li\u003e\n\u003cli\u003e4: kgf\/cm² \u0026amp; psi\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd\u003e8\u003c\/td\u003e\n            \u003ctd\u003e\n\u003cb\u003eThread Code\u003c\/b\u003e [Note 1]\u003c\/td\u003e\n            \u003ctd\u003e\u003cul\u003e\n\u003cli\u003eBlank: PT thread\u003c\/li\u003e\n\u003cli\u003eG: G thread\u003c\/li\u003e\n\u003cli\u003eT: NPT thread\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n       \u003cdiv class=\"note\"\u003e\n          \u003cstrong\u003eNote 1:\u003c\/strong\u003e The pressure gauge dial will correspond to the selected thread type's pressure unit.\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript\u003e\n  (function(){\n    const tabs = document.querySelectorAll('#tabsNav li');\n    const panes = document.querySelectorAll('.tab-pane');\n    \n    tabs.forEach(tab =\u003e {\n      tab.addEventListener('click', () =\u003e {\n        tabs.forEach(t =\u003e t.classList.remove('active'));\n        tab.classList.add('active');\n        \n        panes.forEach(p =\u003e p.classList.remove('active'));\n        const pane = document.getElementById(tab.getAttribute('data-tab'));\n        if(pane) {\n          pane.classList.add('active');\n        }\n      });\n    });\n  })();\n\u003c\/script\u003e\n\n\n\u003c\/body\u003e","products":[{"product_id":"airtac-sr-air-pressure-regulator-sr200082t","title":"Airtac SR series: miniature pressure regulator - SR200082T","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR200082T is an Airtac 200-series mini pressure regulator with NPT 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR200082T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 2, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/2 ↔ male NPT1\/4: NBB1\/4-1\/2\u003cbr\u003emale NPT1\/4 ↔ male NPT1\/4: NBB1\/4-1\/4\u003cbr\u003emale NPT3\/8 ↔ male NPT1\/4: NBB1\/4-3\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/4 ↔ female NPT1\/8: NBD1\/8-1\/4\u003cbr\u003e1\/2 × 1\/3 in: NBKC1\/2-1\/3-1\/4\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/4\u003cbr\u003e3\/8 × 1\/4 in: NBKC3\/8-1\/4-1\/4\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/4\u003cbr\u003e1\/2 in: NBPC1\/2-1\/4,NPLL1\/2-1\/4\u003cbr\u003e1\/4 in: NBPC1\/4-1\/4,NPH1\/4-1\/4,NPHW1\/4-1\/4,NPLL1\/4-1\/4,NPZB1\/4-1\/4\u003cbr\u003e3\/8 in: NBPC3\/8-1\/4,NPH3\/8-1\/4,NPHW3\/8-1\/4,NPLL3\/8-1\/4,NPZB3\/8-1\/4\u003cbr\u003e5\/16 in: NBPC5\/16-1\/4,NPH5\/16-1\/4,NPHW5\/16-1\/4,NPLL5\/16-1\/4,NPZB5\/16-1\/4\u003cbr\u003e1\/4 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF1\/4-1\/4\u003cbr\u003e3\/8 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF3\/8-1\/4\u003cbr\u003e5\/16 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF5\/16-1\/4\u003cbr\u003emain 5\/16 \/ branch 1\/4 in: NPKD5\/16-1\/4-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/2 in: NPC1\/2-1\/4,NPEB1\/2-1\/4,NPED1\/2-1\/4,NPL1\/2-1\/4,NPYB1\/2-1\/4\u003cbr\u003e1\/4 in: NPC1\/4-1\/4,NPEB1\/4-1\/4,NPED1\/4-1\/4,NPL1\/4-1\/4,NPYB1\/4-1\/4\u003cbr\u003e3\/8 in: NPC3\/8-1\/4,NPEB3\/8-1\/4,NPED3\/8-1\/4,NPL3\/8-1\/4,NPYB3\/8-1\/4\u003cbr\u003e5\/16 in: NPC5\/16-1\/4,NPEB5\/16-1\/4,NPED5\/16-1\/4,NPL5\/16-1\/4,NPYB5\/16-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572353724719,"sku":"SR200082T","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/D667EED7-7F72-4DD9-95F9-2DF00A33E8DB.jpg?v=1739354387"},{"product_id":"airtac-sr-air-pressure-regulator-sr20008jnt","title":"Airtac SR series: miniature pressure regulator - SR20008JNT","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008JNT is an Airtac 200-series mini pressure regulator with NPT 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008JNT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type (blank), gauge N, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/2 ↔ male NPT1\/4: NBB1\/4-1\/2\u003cbr\u003emale NPT1\/4 ↔ male NPT1\/4: NBB1\/4-1\/4\u003cbr\u003emale NPT3\/8 ↔ male NPT1\/4: NBB1\/4-3\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/4 ↔ female NPT1\/8: NBD1\/8-1\/4\u003cbr\u003e1\/2 × 1\/3 in: NBKC1\/2-1\/3-1\/4\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/4\u003cbr\u003e3\/8 × 1\/4 in: NBKC3\/8-1\/4-1\/4\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/4\u003cbr\u003e1\/2 in: NBPC1\/2-1\/4,NPLL1\/2-1\/4\u003cbr\u003e1\/4 in: NBPC1\/4-1\/4,NPH1\/4-1\/4,NPHW1\/4-1\/4,NPLL1\/4-1\/4,NPZB1\/4-1\/4\u003cbr\u003e3\/8 in: NBPC3\/8-1\/4,NPH3\/8-1\/4,NPHW3\/8-1\/4,NPLL3\/8-1\/4,NPZB3\/8-1\/4\u003cbr\u003e5\/16 in: NBPC5\/16-1\/4,NPH5\/16-1\/4,NPHW5\/16-1\/4,NPLL5\/16-1\/4,NPZB5\/16-1\/4\u003cbr\u003e1\/4 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF1\/4-1\/4\u003cbr\u003e3\/8 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF3\/8-1\/4\u003cbr\u003e5\/16 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF5\/16-1\/4\u003cbr\u003emain 5\/16 \/ branch 1\/4 in: NPKD5\/16-1\/4-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/2 in: NPC1\/2-1\/4,NPEB1\/2-1\/4,NPED1\/2-1\/4,NPL1\/2-1\/4,NPYB1\/2-1\/4\u003cbr\u003e1\/4 in: NPC1\/4-1\/4,NPEB1\/4-1\/4,NPED1\/4-1\/4,NPL1\/4-1\/4,NPYB1\/4-1\/4\u003cbr\u003e3\/8 in: NPC3\/8-1\/4,NPEB3\/8-1\/4,NPED3\/8-1\/4,NPL3\/8-1\/4,NPYB3\/8-1\/4\u003cbr\u003e5\/16 in: NPC5\/16-1\/4,NPEB5\/16-1\/4,NPED5\/16-1\/4,NPL5\/16-1\/4,NPYB5\/16-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572353790255,"sku":"SR20008JNT","price":12.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/IMG-8240.heic?v=1742980956"},{"product_id":"airtac-sr-air-pressure-regulator-sr20008l2t","title":"Airtac SR series: miniature pressure regulator - SR20008L2T","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008L2T is an Airtac 200-series mini pressure regulator with NPT 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, an included psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008L2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge 2, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/2 ↔ male NPT1\/4: NBB1\/4-1\/2\u003cbr\u003emale NPT1\/4 ↔ male NPT1\/4: NBB1\/4-1\/4\u003cbr\u003emale NPT3\/8 ↔ male NPT1\/4: NBB1\/4-3\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/4 ↔ female NPT1\/8: NBD1\/8-1\/4\u003cbr\u003e1\/2 × 1\/3 in: NBKC1\/2-1\/3-1\/4\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/4\u003cbr\u003e3\/8 × 1\/4 in: NBKC3\/8-1\/4-1\/4\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/4\u003cbr\u003e1\/2 in: NBPC1\/2-1\/4,NPLL1\/2-1\/4\u003cbr\u003e1\/4 in: NBPC1\/4-1\/4,NPH1\/4-1\/4,NPHW1\/4-1\/4,NPLL1\/4-1\/4,NPZB1\/4-1\/4\u003cbr\u003e3\/8 in: NBPC3\/8-1\/4,NPH3\/8-1\/4,NPHW3\/8-1\/4,NPLL3\/8-1\/4,NPZB3\/8-1\/4\u003cbr\u003e5\/16 in: NBPC5\/16-1\/4,NPH5\/16-1\/4,NPHW5\/16-1\/4,NPLL5\/16-1\/4,NPZB5\/16-1\/4\u003cbr\u003e1\/4 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF1\/4-1\/4\u003cbr\u003e3\/8 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF3\/8-1\/4\u003cbr\u003e5\/16 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF5\/16-1\/4\u003cbr\u003emain 5\/16 \/ branch 1\/4 in: NPKD5\/16-1\/4-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/2 in: NPC1\/2-1\/4,NPEB1\/2-1\/4,NPED1\/2-1\/4,NPL1\/2-1\/4,NPYB1\/2-1\/4\u003cbr\u003e1\/4 in: NPC1\/4-1\/4,NPEB1\/4-1\/4,NPED1\/4-1\/4,NPL1\/4-1\/4,NPYB1\/4-1\/4\u003cbr\u003e3\/8 in: NPC3\/8-1\/4,NPEB3\/8-1\/4,NPED3\/8-1\/4,NPL3\/8-1\/4,NPYB3\/8-1\/4\u003cbr\u003e5\/16 in: NPC5\/16-1\/4,NPEB5\/16-1\/4,NPED5\/16-1\/4,NPL5\/16-1\/4,NPYB5\/16-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572355035439,"sku":"SR20008L2T","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/products\/airtac-sr-opt_c59bcf49-1ed1-40d2-8049-3cccd2fb37d1.jpg?v=1677581479"},{"product_id":"airtac-sr-air-pressure-regulator-sr200081","title":"Airtac SR series: miniature pressure regulator - SR200081","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR200081 is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included MPa-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; MPa scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR200081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 1, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572356772143,"sku":"SR200081","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/E90D5BAB-7B4D-4155-9ADC-17B40D8E5C1F.jpg?v=1785485017"},{"product_id":"airtac-sr-air-pressure-regulator-sr200063g","title":"Airtac SR series: miniature pressure regulator - SR200063G","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR200063G is an Airtac 200-series mini pressure regulator with G 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included bar-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eG 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; bar scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR200063G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 3, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/8 ↔ male G1\/8: GBB0101\u003cbr\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G3\/8 ↔ male G1\/8: GBB0103\u003cbr\u003e4 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-01\u003cbr\u003e10: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D\u003cbr\u003e4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D\u003cbr\u003e6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D\u003cbr\u003e8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D\u003cbr\u003e12: GPC1201,GPC1201D,GPL1201,GPL1201D\u003cbr\u003e4; male RA G1\/8 \/ female RB G1\/8: GPHF401,GPHF401D\u003cbr\u003e6; male RA G1\/8 \/ female RB G1\/8: GPHF601,GPHF601D\u003cbr\u003e8; male RA G1\/8 \/ female RB G1\/8: GPHF801,GPHF801D\u003cbr\u003emain 6 \/ branch 4: GPKD6-401,GPKD6-401D\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572356870447,"sku":"SR200063G","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/products\/airtac-sr-opt_0b1064ac-d47c-4710-ad7b-5d157678a033.jpg?v=1677581497"},{"product_id":"airtac-sr-air-pressure-regulator-sr200062t","title":"Airtac SR series: miniature pressure regulator - SR200062T","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR200062T is an Airtac 200-series mini pressure regulator with NPT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR200062T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 2, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/8: NBB1\/8-1\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT3\/8: NBB1\/8-3\/8\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/8\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NBKC5\/32-3\/32-1\/8\u003cbr\u003e1\/4 in: NBPC1\/4-1\/8,NPH1\/4-1\/8,NPHW1\/4-1\/8,NPLL1\/4-1\/8,NPZB1\/4-1\/8\u003cbr\u003e3\/8 in: NBPC3\/8-1\/8,NPLL3\/8-1\/8\u003cbr\u003e5\/16 in: NBPC5\/16-1\/8,NPH5\/16-1\/8,NPHW5\/16-1\/8,NPLL5\/16-1\/8,NPZB5\/16-1\/8\u003cbr\u003e5\/32 in: NBPC5\/32-1\/8,NPH5\/32-1\/8,NPHW5\/32-1\/8,NPLL5\/32-1\/8\u003cbr\u003e1\/4 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF1\/4-1\/8\u003cbr\u003e5\/16 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/16-1\/8\u003cbr\u003e5\/32 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/32-1\/8\u003cbr\u003emain 1\/4 \/ branches 5\/32 in: NPKD1\/4-5\/32-1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/4 in: NPC1\/4-1\/8,NPEB1\/4-1\/8,NPED1\/4-1\/8,NPL1\/4-1\/8,NPYB1\/4-1\/8\u003cbr\u003e3\/8 in: NPC3\/8-1\/8,NPEB3\/8-1\/8,NPED3\/8-1\/8,NPL3\/8-1\/8,NPYB3\/8-1\/8\u003cbr\u003e5\/16 in: NPC5\/16-1\/8,NPEB5\/16-1\/8,NPED5\/16-1\/8,NPL5\/16-1\/8,NPYB5\/16-1\/8\u003cbr\u003e5\/32 in: NPC5\/32-1\/8,NPEB5\/32-1\/8,NPED5\/32-1\/8,NPL5\/32-1\/8,NPYB5\/32-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NUE95A5\/32X3\/32-100BK,NUE95A5\/32X3\/32-100BR,NUE95A5\/32X3\/32-100BU,NUE95A5\/32X3\/32-100C,NUE95A5\/32X3\/32-100CB,NUE95A5\/32X3\/32-100CE,NUE95A5\/32X3\/32-100CG,NUE95A5\/32X3\/32-100CR,NUE95A5\/32X3\/32-100CY,NUE95A5\/32X3\/32-100GA,NUE95A5\/32X3\/32-100GE,NUE95A5\/32X3\/32-100GN,NUE95A5\/32X3\/32-100R,NUE95A5\/32X3\/32-100WH,NUE95A5\/32X3\/32-100Y,NUE95A5\/32X3\/32-250BK,NUE95A5\/32X3\/32-250BR,NUE95A5\/32X3\/32-250BU,NUE95A5\/32X3\/32-250C,NUE95A5\/32X3\/32-250CB,NUE95A5\/32X3\/32-250CE,NUE95A5\/32X3\/32-250CG,NUE95A5\/32X3\/32-250CR,NUE95A5\/32X3\/32-250CY,NUE95A5\/32X3\/32-250GA,NUE95A5\/32X3\/32-250GE,NUE95A5\/32X3\/32-250GN,NUE95A5\/32X3\/32-250R,NUE95A5\/32X3\/32-250WH,NUE95A5\/32X3\/32-250Y,NUE95A5\/32X3\/32-500BK,NUE95A5\/32X3\/32-500BR,NUE95A5\/32X3\/32-500BU,NUE95A5\/32X3\/32-500C,NUE95A5\/32X3\/32-500CB,NUE95A5\/32X3\/32-500CE,NUE95A5\/32X3\/32-500CG,NUE95A5\/32X3\/32-500CR,NUE95A5\/32X3\/32-500CY,NUE95A5\/32X3\/32-500GA,NUE95A5\/32X3\/32-500GE,NUE95A5\/32X3\/32-500GN,NUE95A5\/32X3\/32-500R,NUE95A5\/32X3\/32-500WH,NUE95A5\/32X3\/32-500Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eNBKC5\/32-3\/32-1\/8 specifies 3\/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube.\u003c\/p\u003e\n\u003cp\u003eThe listed NUE95A tubes serve IN and OUT only through a listed exact 5\/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5\/32-3\/32-1\/8, the supplier must also confirm 3\/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1\/8 in OD tube. These tubes are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eNUE95A5\/32X3\/32 is ether-based PU, Shore A95±2, with 5\/32 in OD × 3\/32 in ID and 1\/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit.\u003c\/p\u003e\n\u003cp\u003eIn NUE codes, 100\/250\/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572356968751,"sku":"SR200062T","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/products\/airtac-sr-opt_4d683853-4425-4fae-a8da-f9faba36c55f.jpg?v=1677581499"},{"product_id":"airtac-sr-air-pressure-regulator-sr20008j2t","title":"Airtac SR series: miniature pressure regulator - SR20008J2T","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008J2T is an Airtac 200-series mini pressure regulator with NPT 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, an included psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008J2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type (blank), gauge 2, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/2 ↔ male NPT1\/4: NBB1\/4-1\/2\u003cbr\u003emale NPT1\/4 ↔ male NPT1\/4: NBB1\/4-1\/4\u003cbr\u003emale NPT3\/8 ↔ male NPT1\/4: NBB1\/4-3\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/4 ↔ female NPT1\/8: NBD1\/8-1\/4\u003cbr\u003e1\/2 × 1\/3 in: NBKC1\/2-1\/3-1\/4\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/4\u003cbr\u003e3\/8 × 1\/4 in: NBKC3\/8-1\/4-1\/4\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/4\u003cbr\u003e1\/2 in: NBPC1\/2-1\/4,NPLL1\/2-1\/4\u003cbr\u003e1\/4 in: NBPC1\/4-1\/4,NPH1\/4-1\/4,NPHW1\/4-1\/4,NPLL1\/4-1\/4,NPZB1\/4-1\/4\u003cbr\u003e3\/8 in: NBPC3\/8-1\/4,NPH3\/8-1\/4,NPHW3\/8-1\/4,NPLL3\/8-1\/4,NPZB3\/8-1\/4\u003cbr\u003e5\/16 in: NBPC5\/16-1\/4,NPH5\/16-1\/4,NPHW5\/16-1\/4,NPLL5\/16-1\/4,NPZB5\/16-1\/4\u003cbr\u003e1\/4 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF1\/4-1\/4\u003cbr\u003e3\/8 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF3\/8-1\/4\u003cbr\u003e5\/16 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF5\/16-1\/4\u003cbr\u003emain 5\/16 \/ branch 1\/4 in: NPKD5\/16-1\/4-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/2 in: NPC1\/2-1\/4,NPEB1\/2-1\/4,NPED1\/2-1\/4,NPL1\/2-1\/4,NPYB1\/2-1\/4\u003cbr\u003e1\/4 in: NPC1\/4-1\/4,NPEB1\/4-1\/4,NPED1\/4-1\/4,NPL1\/4-1\/4,NPYB1\/4-1\/4\u003cbr\u003e3\/8 in: NPC3\/8-1\/4,NPEB3\/8-1\/4,NPED3\/8-1\/4,NPL3\/8-1\/4,NPYB3\/8-1\/4\u003cbr\u003e5\/16 in: NPC5\/16-1\/4,NPEB5\/16-1\/4,NPED5\/16-1\/4,NPL5\/16-1\/4,NPYB5\/16-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572359819567,"sku":"SR20008J2T","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/products\/airtac-sr-opt_4d54f78e-1d4c-4ceb-aa12-607f8e8e0678.jpg?v=1677581523"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006l2t","title":"Airtac SR series: miniature pressure regulator - SR20006L2T","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006L2T is an Airtac 200-series mini pressure regulator with NPT 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, an included psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006L2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge 2, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/8: NBB1\/8-1\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT3\/8: NBB1\/8-3\/8\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/8\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NBKC5\/32-3\/32-1\/8\u003cbr\u003e1\/4 in: NBPC1\/4-1\/8,NPH1\/4-1\/8,NPHW1\/4-1\/8,NPLL1\/4-1\/8,NPZB1\/4-1\/8\u003cbr\u003e3\/8 in: NBPC3\/8-1\/8,NPLL3\/8-1\/8\u003cbr\u003e5\/16 in: NBPC5\/16-1\/8,NPH5\/16-1\/8,NPHW5\/16-1\/8,NPLL5\/16-1\/8,NPZB5\/16-1\/8\u003cbr\u003e5\/32 in: NBPC5\/32-1\/8,NPH5\/32-1\/8,NPHW5\/32-1\/8,NPLL5\/32-1\/8\u003cbr\u003e1\/4 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF1\/4-1\/8\u003cbr\u003e5\/16 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/16-1\/8\u003cbr\u003e5\/32 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/32-1\/8\u003cbr\u003emain 1\/4 \/ branches 5\/32 in: NPKD1\/4-5\/32-1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/4 in: NPC1\/4-1\/8,NPEB1\/4-1\/8,NPED1\/4-1\/8,NPL1\/4-1\/8,NPYB1\/4-1\/8\u003cbr\u003e3\/8 in: NPC3\/8-1\/8,NPEB3\/8-1\/8,NPED3\/8-1\/8,NPL3\/8-1\/8,NPYB3\/8-1\/8\u003cbr\u003e5\/16 in: NPC5\/16-1\/8,NPEB5\/16-1\/8,NPED5\/16-1\/8,NPL5\/16-1\/8,NPYB5\/16-1\/8\u003cbr\u003e5\/32 in: NPC5\/32-1\/8,NPEB5\/32-1\/8,NPED5\/32-1\/8,NPL5\/32-1\/8,NPYB5\/32-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NUE95A5\/32X3\/32-100BK,NUE95A5\/32X3\/32-100BR,NUE95A5\/32X3\/32-100BU,NUE95A5\/32X3\/32-100C,NUE95A5\/32X3\/32-100CB,NUE95A5\/32X3\/32-100CE,NUE95A5\/32X3\/32-100CG,NUE95A5\/32X3\/32-100CR,NUE95A5\/32X3\/32-100CY,NUE95A5\/32X3\/32-100GA,NUE95A5\/32X3\/32-100GE,NUE95A5\/32X3\/32-100GN,NUE95A5\/32X3\/32-100R,NUE95A5\/32X3\/32-100WH,NUE95A5\/32X3\/32-100Y,NUE95A5\/32X3\/32-250BK,NUE95A5\/32X3\/32-250BR,NUE95A5\/32X3\/32-250BU,NUE95A5\/32X3\/32-250C,NUE95A5\/32X3\/32-250CB,NUE95A5\/32X3\/32-250CE,NUE95A5\/32X3\/32-250CG,NUE95A5\/32X3\/32-250CR,NUE95A5\/32X3\/32-250CY,NUE95A5\/32X3\/32-250GA,NUE95A5\/32X3\/32-250GE,NUE95A5\/32X3\/32-250GN,NUE95A5\/32X3\/32-250R,NUE95A5\/32X3\/32-250WH,NUE95A5\/32X3\/32-250Y,NUE95A5\/32X3\/32-500BK,NUE95A5\/32X3\/32-500BR,NUE95A5\/32X3\/32-500BU,NUE95A5\/32X3\/32-500C,NUE95A5\/32X3\/32-500CB,NUE95A5\/32X3\/32-500CE,NUE95A5\/32X3\/32-500CG,NUE95A5\/32X3\/32-500CR,NUE95A5\/32X3\/32-500CY,NUE95A5\/32X3\/32-500GA,NUE95A5\/32X3\/32-500GE,NUE95A5\/32X3\/32-500GN,NUE95A5\/32X3\/32-500R,NUE95A5\/32X3\/32-500WH,NUE95A5\/32X3\/32-500Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eNBKC5\/32-3\/32-1\/8 specifies 3\/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube.\u003c\/p\u003e\n\u003cp\u003eThe listed NUE95A tubes serve IN and OUT only through a listed exact 5\/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5\/32-3\/32-1\/8, the supplier must also confirm 3\/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1\/8 in OD tube. These tubes are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eNUE95A5\/32X3\/32 is ether-based PU, Shore A95±2, with 5\/32 in OD × 3\/32 in ID and 1\/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit.\u003c\/p\u003e\n\u003cp\u003eIn NUE codes, 100\/250\/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572359983407,"sku":"SR20006L2T","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/products\/regulator-compressed-air-30479-2661627-B10_ddee018e-979d-4456-a6b6-c095ce5a04a5.jpg?v=1677581525"},{"product_id":"airtac-sr-air-pressure-regulator-sr200061","title":"Airtac SR series: miniature pressure regulator - SR200061","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR200061 is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included MPa-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; MPa scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR200061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 1, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572360114479,"sku":"SR200061","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/SR200061.jpg?v=1760081747"},{"product_id":"airtac-sr-air-pressure-regulator-sr200084","title":"Airtac SR series: miniature pressure regulator - SR200084","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR200084 is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included kgf\/cm² and psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; kgf\/cm² and psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR200084\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 4, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572361883951,"sku":"SR200084","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/773A8F3C-71F8-4BDA-90A1-74F09D4533F2.jpg?v=1744439424"},{"product_id":"airtac-sr-air-pressure-regulator-sr200083g","title":"Airtac SR series: miniature pressure regulator - SR200083G","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR200083G is an Airtac 200-series mini pressure regulator with G 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included bar-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; bar scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR200083G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 3, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G1\/4 ↔ male G1\/4: GBB0202\u003cbr\u003emale G3\/8 ↔ male G1\/4: GBB0203\u003cbr\u003emale G1\/2 ↔ male G1\/4: GBB0204\u003cbr\u003emale G1\/4 ↔ female G1\/8: GBD0102\u003cbr\u003e6 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-02\u003cbr\u003e10 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: GBKC1075-02\u003cbr\u003e12 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: GBKC1209-02\u003cbr\u003e10: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D\u003cbr\u003e12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D\u003cbr\u003e4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D\u003cbr\u003e6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D\u003cbr\u003e8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D\u003cbr\u003e10; male RA G1\/4 \/ female RB G1\/4: GPHF1002,GPHF1002D\u003cbr\u003e6; male RA G1\/4 \/ female RB G1\/4: GPHF602,GPHF602D\u003cbr\u003e8; male RA G1\/4 \/ female RB G1\/4: GPHF802,GPHF802D\u003cbr\u003emain 8 \/ branch 6: GPKD8-602,GPKD8-602D\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572362015023,"sku":"SR200083G","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/products\/airtac-sr-opt_d2937e1a-75f2-462b-ac19-c3724da7a4b6.jpg?v=1677581556"},{"product_id":"airtac-sr-air-pressure-regulator-sr200064","title":"Airtac SR series: miniature pressure regulator - SR200064","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR200064 is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, an included kgf\/cm² and psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; kgf\/cm² and psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR200064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge 4, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":44572362211631,"sku":"SR200064","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/products\/airtac-sr-opt.jpg?v=1677581558"},{"product_id":"airtac-sr-regulatormini-type-sr20006j1","title":"Airtac SR series: miniature pressure regulator - SR20006J1","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006J1 is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, an included MPa-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; MPa scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006J1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge 1, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997046288687,"sku":"SR20006J1","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_47fe55e7-3300-434c-9e2d-296b51bc3691.jpg?v=1711389123"},{"product_id":"airtac-sr-regulatormini-type-sr20006j2t","title":"Airtac SR series: miniature pressure regulator - SR20006J2T","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006J2T is an Airtac 200-series mini pressure regulator with NPT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, an included psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006J2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge 2, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/8: NBB1\/8-1\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT3\/8: NBB1\/8-3\/8\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/8\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NBKC5\/32-3\/32-1\/8\u003cbr\u003e1\/4 in: NBPC1\/4-1\/8,NPH1\/4-1\/8,NPHW1\/4-1\/8,NPLL1\/4-1\/8,NPZB1\/4-1\/8\u003cbr\u003e3\/8 in: NBPC3\/8-1\/8,NPLL3\/8-1\/8\u003cbr\u003e5\/16 in: NBPC5\/16-1\/8,NPH5\/16-1\/8,NPHW5\/16-1\/8,NPLL5\/16-1\/8,NPZB5\/16-1\/8\u003cbr\u003e5\/32 in: NBPC5\/32-1\/8,NPH5\/32-1\/8,NPHW5\/32-1\/8,NPLL5\/32-1\/8\u003cbr\u003e1\/4 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF1\/4-1\/8\u003cbr\u003e5\/16 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/16-1\/8\u003cbr\u003e5\/32 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/32-1\/8\u003cbr\u003emain 1\/4 \/ branches 5\/32 in: NPKD1\/4-5\/32-1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/4 in: NPC1\/4-1\/8,NPEB1\/4-1\/8,NPED1\/4-1\/8,NPL1\/4-1\/8,NPYB1\/4-1\/8\u003cbr\u003e3\/8 in: NPC3\/8-1\/8,NPEB3\/8-1\/8,NPED3\/8-1\/8,NPL3\/8-1\/8,NPYB3\/8-1\/8\u003cbr\u003e5\/16 in: NPC5\/16-1\/8,NPEB5\/16-1\/8,NPED5\/16-1\/8,NPL5\/16-1\/8,NPYB5\/16-1\/8\u003cbr\u003e5\/32 in: NPC5\/32-1\/8,NPEB5\/32-1\/8,NPED5\/32-1\/8,NPL5\/32-1\/8,NPYB5\/32-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NUE95A5\/32X3\/32-100BK,NUE95A5\/32X3\/32-100BR,NUE95A5\/32X3\/32-100BU,NUE95A5\/32X3\/32-100C,NUE95A5\/32X3\/32-100CB,NUE95A5\/32X3\/32-100CE,NUE95A5\/32X3\/32-100CG,NUE95A5\/32X3\/32-100CR,NUE95A5\/32X3\/32-100CY,NUE95A5\/32X3\/32-100GA,NUE95A5\/32X3\/32-100GE,NUE95A5\/32X3\/32-100GN,NUE95A5\/32X3\/32-100R,NUE95A5\/32X3\/32-100WH,NUE95A5\/32X3\/32-100Y,NUE95A5\/32X3\/32-250BK,NUE95A5\/32X3\/32-250BR,NUE95A5\/32X3\/32-250BU,NUE95A5\/32X3\/32-250C,NUE95A5\/32X3\/32-250CB,NUE95A5\/32X3\/32-250CE,NUE95A5\/32X3\/32-250CG,NUE95A5\/32X3\/32-250CR,NUE95A5\/32X3\/32-250CY,NUE95A5\/32X3\/32-250GA,NUE95A5\/32X3\/32-250GE,NUE95A5\/32X3\/32-250GN,NUE95A5\/32X3\/32-250R,NUE95A5\/32X3\/32-250WH,NUE95A5\/32X3\/32-250Y,NUE95A5\/32X3\/32-500BK,NUE95A5\/32X3\/32-500BR,NUE95A5\/32X3\/32-500BU,NUE95A5\/32X3\/32-500C,NUE95A5\/32X3\/32-500CB,NUE95A5\/32X3\/32-500CE,NUE95A5\/32X3\/32-500CG,NUE95A5\/32X3\/32-500CR,NUE95A5\/32X3\/32-500CY,NUE95A5\/32X3\/32-500GA,NUE95A5\/32X3\/32-500GE,NUE95A5\/32X3\/32-500GN,NUE95A5\/32X3\/32-500R,NUE95A5\/32X3\/32-500WH,NUE95A5\/32X3\/32-500Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eNBKC5\/32-3\/32-1\/8 specifies 3\/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube.\u003c\/p\u003e\n\u003cp\u003eThe listed NUE95A tubes serve IN and OUT only through a listed exact 5\/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5\/32-3\/32-1\/8, the supplier must also confirm 3\/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1\/8 in OD tube. These tubes are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eNUE95A5\/32X3\/32 is ether-based PU, Shore A95±2, with 5\/32 in OD × 3\/32 in ID and 1\/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit.\u003c\/p\u003e\n\u003cp\u003eIn NUE codes, 100\/250\/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997049467183,"sku":"SR20006J2T","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_01ba28ea-eb97-48ca-97d0-9b4574c47b86.jpg?v=1711389148"},{"product_id":"airtac-sr-regulatormini-type-sr20006j3g","title":"Airtac SR series: miniature pressure regulator - SR20006J3G","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006J3G is an Airtac 200-series mini pressure regulator with G 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, an included bar-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eG 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; bar scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006J3G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge 3, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/8 ↔ male G1\/8: GBB0101\u003cbr\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G3\/8 ↔ male G1\/8: GBB0103\u003cbr\u003e4 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-01\u003cbr\u003e10: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D\u003cbr\u003e4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D\u003cbr\u003e6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D\u003cbr\u003e8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D\u003cbr\u003e12: GPC1201,GPC1201D,GPL1201,GPL1201D\u003cbr\u003e4; male RA G1\/8 \/ female RB G1\/8: GPHF401,GPHF401D\u003cbr\u003e6; male RA G1\/8 \/ female RB G1\/8: GPHF601,GPHF601D\u003cbr\u003e8; male RA G1\/8 \/ female RB G1\/8: GPHF801,GPHF801D\u003cbr\u003emain 6 \/ branch 4: GPKD6-401,GPKD6-401D\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997054284079,"sku":"SR20006J3G","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/39FD7FD0-3B86-4361-AA96-799633E3E7BB.jpg?v=1780022544"},{"product_id":"airtac-sr-regulatormini-type-sr20006j4","title":"Airtac SR series: miniature pressure regulator - SR20006J4","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006J4 is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, an included kgf\/cm² and psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; kgf\/cm² and psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006J4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge 4, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997057823023,"sku":"SR20006J4","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_be85433a-3ab4-4a8a-9846-394383ebf9d7.jpg?v=1711389198"},{"product_id":"airtac-sr-regulatormini-type-sr20006l1","title":"Airtac SR series: miniature pressure regulator - SR20006L1","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006L1 is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, an included MPa-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; MPa scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge 1, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997081317679,"sku":"SR20006L1","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_6b2b8aea-ccce-41a8-a891-8f61a80f8e14.jpg?v=1711389325"},{"product_id":"airtac-sr-regulatormini-type-sr20006l3g","title":"Airtac SR series: miniature pressure regulator - SR20006L3G","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006L3G is an Airtac 200-series mini pressure regulator with G 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, an included bar-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eG 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; bar scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006L3G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge 3, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/8 ↔ male G1\/8: GBB0101\u003cbr\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G3\/8 ↔ male G1\/8: GBB0103\u003cbr\u003e4 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-01\u003cbr\u003e10: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D\u003cbr\u003e4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D\u003cbr\u003e6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D\u003cbr\u003e8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D\u003cbr\u003e12: GPC1201,GPC1201D,GPL1201,GPL1201D\u003cbr\u003e4; male RA G1\/8 \/ female RB G1\/8: GPHF401,GPHF401D\u003cbr\u003e6; male RA G1\/8 \/ female RB G1\/8: GPHF601,GPHF601D\u003cbr\u003e8; male RA G1\/8 \/ female RB G1\/8: GPHF801,GPHF801D\u003cbr\u003emain 6 \/ branch 4: GPKD6-401,GPKD6-401D\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997090885935,"sku":"SR20006L3G","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_a60749e7-7951-491c-8e43-5b215f48383d.jpg?v=1711389375"},{"product_id":"airtac-sr-regulatormini-type-sr20006lj2t","title":"Airtac SR series: miniature pressure regulator - SR20006LJ2T","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006LJ2T is an Airtac 200-series mini pressure regulator with NPT 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, an included psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006LJ2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type L, gauge 2, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/8: NBB1\/8-1\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT3\/8: NBB1\/8-3\/8\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/8\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NBKC5\/32-3\/32-1\/8\u003cbr\u003e1\/4 in: NBPC1\/4-1\/8,NPH1\/4-1\/8,NPHW1\/4-1\/8,NPLL1\/4-1\/8,NPZB1\/4-1\/8\u003cbr\u003e3\/8 in: NBPC3\/8-1\/8,NPLL3\/8-1\/8\u003cbr\u003e5\/16 in: NBPC5\/16-1\/8,NPH5\/16-1\/8,NPHW5\/16-1\/8,NPLL5\/16-1\/8,NPZB5\/16-1\/8\u003cbr\u003e5\/32 in: NBPC5\/32-1\/8,NPH5\/32-1\/8,NPHW5\/32-1\/8,NPLL5\/32-1\/8\u003cbr\u003e1\/4 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF1\/4-1\/8\u003cbr\u003e5\/16 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/16-1\/8\u003cbr\u003e5\/32 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/32-1\/8\u003cbr\u003emain 1\/4 \/ branches 5\/32 in: NPKD1\/4-5\/32-1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/4 in: NPC1\/4-1\/8,NPEB1\/4-1\/8,NPED1\/4-1\/8,NPL1\/4-1\/8,NPYB1\/4-1\/8\u003cbr\u003e3\/8 in: NPC3\/8-1\/8,NPEB3\/8-1\/8,NPED3\/8-1\/8,NPL3\/8-1\/8,NPYB3\/8-1\/8\u003cbr\u003e5\/16 in: NPC5\/16-1\/8,NPEB5\/16-1\/8,NPED5\/16-1\/8,NPL5\/16-1\/8,NPYB5\/16-1\/8\u003cbr\u003e5\/32 in: NPC5\/32-1\/8,NPEB5\/32-1\/8,NPED5\/32-1\/8,NPL5\/32-1\/8,NPYB5\/32-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NUE95A5\/32X3\/32-100BK,NUE95A5\/32X3\/32-100BR,NUE95A5\/32X3\/32-100BU,NUE95A5\/32X3\/32-100C,NUE95A5\/32X3\/32-100CB,NUE95A5\/32X3\/32-100CE,NUE95A5\/32X3\/32-100CG,NUE95A5\/32X3\/32-100CR,NUE95A5\/32X3\/32-100CY,NUE95A5\/32X3\/32-100GA,NUE95A5\/32X3\/32-100GE,NUE95A5\/32X3\/32-100GN,NUE95A5\/32X3\/32-100R,NUE95A5\/32X3\/32-100WH,NUE95A5\/32X3\/32-100Y,NUE95A5\/32X3\/32-250BK,NUE95A5\/32X3\/32-250BR,NUE95A5\/32X3\/32-250BU,NUE95A5\/32X3\/32-250C,NUE95A5\/32X3\/32-250CB,NUE95A5\/32X3\/32-250CE,NUE95A5\/32X3\/32-250CG,NUE95A5\/32X3\/32-250CR,NUE95A5\/32X3\/32-250CY,NUE95A5\/32X3\/32-250GA,NUE95A5\/32X3\/32-250GE,NUE95A5\/32X3\/32-250GN,NUE95A5\/32X3\/32-250R,NUE95A5\/32X3\/32-250WH,NUE95A5\/32X3\/32-250Y,NUE95A5\/32X3\/32-500BK,NUE95A5\/32X3\/32-500BR,NUE95A5\/32X3\/32-500BU,NUE95A5\/32X3\/32-500C,NUE95A5\/32X3\/32-500CB,NUE95A5\/32X3\/32-500CE,NUE95A5\/32X3\/32-500CG,NUE95A5\/32X3\/32-500CR,NUE95A5\/32X3\/32-500CY,NUE95A5\/32X3\/32-500GA,NUE95A5\/32X3\/32-500GE,NUE95A5\/32X3\/32-500GN,NUE95A5\/32X3\/32-500R,NUE95A5\/32X3\/32-500WH,NUE95A5\/32X3\/32-500Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eNBKC5\/32-3\/32-1\/8 specifies 3\/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube.\u003c\/p\u003e\n\u003cp\u003eThe listed NUE95A tubes serve IN and OUT only through a listed exact 5\/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5\/32-3\/32-1\/8, the supplier must also confirm 3\/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1\/8 in OD tube. These tubes are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eNUE95A5\/32X3\/32 is ether-based PU, Shore A95±2, with 5\/32 in OD × 3\/32 in ID and 1\/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit.\u003c\/p\u003e\n\u003cp\u003eIn NUE codes, 100\/250\/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997116117295,"sku":"SR20006LJ2T","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_e922ddc3-c60f-48ae-8b13-af59f5a01670.jpg?v=1711389531"},{"product_id":"airtac-sr-regulatormini-type-sr20006lj3g","title":"Airtac SR series: miniature pressure regulator - SR20006LJ3G","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006LJ3G is an Airtac 200-series mini pressure regulator with G 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, an included bar-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eG 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; bar scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006LJ3G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type L, gauge 3, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/8 ↔ male G1\/8: GBB0101\u003cbr\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G3\/8 ↔ male G1\/8: GBB0103\u003cbr\u003e4 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-01\u003cbr\u003e10: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D\u003cbr\u003e4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D\u003cbr\u003e6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D\u003cbr\u003e8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D\u003cbr\u003e12: GPC1201,GPC1201D,GPL1201,GPL1201D\u003cbr\u003e4; male RA G1\/8 \/ female RB G1\/8: GPHF401,GPHF401D\u003cbr\u003e6; male RA G1\/8 \/ female RB G1\/8: GPHF601,GPHF601D\u003cbr\u003e8; male RA G1\/8 \/ female RB G1\/8: GPHF801,GPHF801D\u003cbr\u003emain 6 \/ branch 4: GPKD6-401,GPKD6-401D\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997120540975,"sku":"SR20006LJ3G","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_922745fb-305b-4a96-97ff-e6fff56abef5.jpg?v=1711389556"},{"product_id":"airtac-sr-regulatormini-type-sr20006lj4","title":"Airtac SR series: miniature pressure regulator - SR20006LJ4","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006LJ4 is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, an included kgf\/cm² and psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; kgf\/cm² and psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006LJ4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type L, gauge 4, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997125783855,"sku":"SR20006LJ4","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_276bc5bb-68d0-47b7-ba11-1eb70e4cdeda.jpg?v=1711389584"},{"product_id":"airtac-sr-regulatormini-type-sr20008j1","title":"Airtac SR series: miniature pressure regulator - SR20008J1","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008J1 is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, an included MPa-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; MPa scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008J1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type (blank), gauge 1, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997176410415,"sku":"SR20008J1","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_754c690f-2d33-43e2-b6dc-8514515890d2.jpg?v=1711389897"},{"product_id":"airtac-sr-regulatormini-type-sr20008j3g","title":"Airtac SR series: miniature pressure regulator - SR20008J3G","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008J3G is an Airtac 200-series mini pressure regulator with G 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, an included bar-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; bar scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008J3G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type (blank), gauge 3, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G1\/4 ↔ male G1\/4: GBB0202\u003cbr\u003emale G3\/8 ↔ male G1\/4: GBB0203\u003cbr\u003emale G1\/2 ↔ male G1\/4: GBB0204\u003cbr\u003emale G1\/4 ↔ female G1\/8: GBD0102\u003cbr\u003e6 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-02\u003cbr\u003e10 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: GBKC1075-02\u003cbr\u003e12 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: GBKC1209-02\u003cbr\u003e10: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D\u003cbr\u003e12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D\u003cbr\u003e4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D\u003cbr\u003e6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D\u003cbr\u003e8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D\u003cbr\u003e10; male RA G1\/4 \/ female RB G1\/4: GPHF1002,GPHF1002D\u003cbr\u003e6; male RA G1\/4 \/ female RB G1\/4: GPHF602,GPHF602D\u003cbr\u003e8; male RA G1\/4 \/ female RB G1\/4: GPHF802,GPHF802D\u003cbr\u003emain 8 \/ branch 6: GPKD8-602,GPKD8-602D\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997180637487,"sku":"SR20008J3G","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_ffe55fc9-6228-44ba-9513-8dfe8b97f7ef.jpg?v=1711389930"},{"product_id":"airtac-sr-regulatormini-type-sr20008j4","title":"Airtac SR series: miniature pressure regulator - SR20008J4","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008J4 is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, an included kgf\/cm² and psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; kgf\/cm² and psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008J4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type (blank), gauge 4, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997184373039,"sku":"SR20008J4","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_d60f80a2-566c-476f-afde-02658f09007b.jpg?v=1711389955"},{"product_id":"airtac-sr-regulatormini-type-sr20008l1","title":"Airtac SR series: miniature pressure regulator - SR20008L1","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008L1 is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, an included MPa-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; MPa scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge 1, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997203542319,"sku":"SR20008L1","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_bfc347e7-083b-41b8-9194-95b95ca779a2.jpg?v=1711390080"},{"product_id":"airtac-sr-regulatormini-type-sr20008l3g","title":"Airtac SR series: miniature pressure regulator - SR20008L3G","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008L3G is an Airtac 200-series mini pressure regulator with G 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, an included bar-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; bar scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008L3G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge 3, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G1\/4 ↔ male G1\/4: GBB0202\u003cbr\u003emale G3\/8 ↔ male G1\/4: GBB0203\u003cbr\u003emale G1\/2 ↔ male G1\/4: GBB0204\u003cbr\u003emale G1\/4 ↔ female G1\/8: GBD0102\u003cbr\u003e6 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-02\u003cbr\u003e10 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: GBKC1075-02\u003cbr\u003e12 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: GBKC1209-02\u003cbr\u003e10: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D\u003cbr\u003e12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D\u003cbr\u003e4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D\u003cbr\u003e6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D\u003cbr\u003e8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D\u003cbr\u003e10; male RA G1\/4 \/ female RB G1\/4: GPHF1002,GPHF1002D\u003cbr\u003e6; male RA G1\/4 \/ female RB G1\/4: GPHF602,GPHF602D\u003cbr\u003e8; male RA G1\/4 \/ female RB G1\/4: GPHF802,GPHF802D\u003cbr\u003emain 8 \/ branch 6: GPKD8-602,GPKD8-602D\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997215207727,"sku":"SR20008L3G","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_8a61d320-c632-426d-9f4b-610029e6bafd.jpg?v=1711390132"},{"product_id":"airtac-sr-regulatormini-type-sr20008l4","title":"Airtac SR series: miniature pressure regulator - SR20008L4","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008L4 is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, an included kgf\/cm² and psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; kgf\/cm² and psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008L4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge 4, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997218386223,"sku":"SR20008L4","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_511cb8d5-c8c7-4e76-96fd-e3acbb4f0c58.jpg?v=1711390158"},{"product_id":"airtac-sr-regulatormini-type-sr20008lj1","title":"Airtac SR series: miniature pressure regulator - SR20008LJ1","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008LJ1 is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, an included MPa-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; MPa scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008LJ1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type L, gauge 1, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997239849263,"sku":"SR20008LJ1","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_98c21b43-4bd9-47ad-bdb3-d797ef915da3.jpg?v=1711390287"},{"product_id":"airtac-sr-regulatormini-type-sr20008lj2t","title":"Airtac SR series: miniature pressure regulator - SR20008LJ2T","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008LJ2T is an Airtac 200-series mini pressure regulator with NPT 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, an included psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008LJ2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type L, gauge 2, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/2 ↔ male NPT1\/4: NBB1\/4-1\/2\u003cbr\u003emale NPT1\/4 ↔ male NPT1\/4: NBB1\/4-1\/4\u003cbr\u003emale NPT3\/8 ↔ male NPT1\/4: NBB1\/4-3\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/4 ↔ female NPT1\/8: NBD1\/8-1\/4\u003cbr\u003e1\/2 × 1\/3 in: NBKC1\/2-1\/3-1\/4\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/4\u003cbr\u003e3\/8 × 1\/4 in: NBKC3\/8-1\/4-1\/4\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/4\u003cbr\u003e1\/2 in: NBPC1\/2-1\/4,NPLL1\/2-1\/4\u003cbr\u003e1\/4 in: NBPC1\/4-1\/4,NPH1\/4-1\/4,NPHW1\/4-1\/4,NPLL1\/4-1\/4,NPZB1\/4-1\/4\u003cbr\u003e3\/8 in: NBPC3\/8-1\/4,NPH3\/8-1\/4,NPHW3\/8-1\/4,NPLL3\/8-1\/4,NPZB3\/8-1\/4\u003cbr\u003e5\/16 in: NBPC5\/16-1\/4,NPH5\/16-1\/4,NPHW5\/16-1\/4,NPLL5\/16-1\/4,NPZB5\/16-1\/4\u003cbr\u003e1\/4 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF1\/4-1\/4\u003cbr\u003e3\/8 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF3\/8-1\/4\u003cbr\u003e5\/16 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF5\/16-1\/4\u003cbr\u003emain 5\/16 \/ branch 1\/4 in: NPKD5\/16-1\/4-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/2 in: NPC1\/2-1\/4,NPEB1\/2-1\/4,NPED1\/2-1\/4,NPL1\/2-1\/4,NPYB1\/2-1\/4\u003cbr\u003e1\/4 in: NPC1\/4-1\/4,NPEB1\/4-1\/4,NPED1\/4-1\/4,NPL1\/4-1\/4,NPYB1\/4-1\/4\u003cbr\u003e3\/8 in: NPC3\/8-1\/4,NPEB3\/8-1\/4,NPED3\/8-1\/4,NPL3\/8-1\/4,NPYB3\/8-1\/4\u003cbr\u003e5\/16 in: NPC5\/16-1\/4,NPEB5\/16-1\/4,NPED5\/16-1\/4,NPL5\/16-1\/4,NPYB5\/16-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997243420975,"sku":"SR20008LJ2T","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_71edb9b8-5cfe-4b77-8a5c-5288642ef1e7.jpg?v=1711390311"},{"product_id":"airtac-sr-regulatormini-type-sr20008lj3g","title":"Airtac SR series: miniature pressure regulator - SR20008LJ3G","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008LJ3G is an Airtac 200-series mini pressure regulator with G 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, an included bar-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; bar scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008LJ3G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type L, gauge 3, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G1\/4 ↔ male G1\/4: GBB0202\u003cbr\u003emale G3\/8 ↔ male G1\/4: GBB0203\u003cbr\u003emale G1\/2 ↔ male G1\/4: GBB0204\u003cbr\u003emale G1\/4 ↔ female G1\/8: GBD0102\u003cbr\u003e6 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-02\u003cbr\u003e10 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: GBKC1075-02\u003cbr\u003e12 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: GBKC1209-02\u003cbr\u003e10: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D\u003cbr\u003e12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D\u003cbr\u003e4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D\u003cbr\u003e6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D\u003cbr\u003e8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D\u003cbr\u003e10; male RA G1\/4 \/ female RB G1\/4: GPHF1002,GPHF1002D\u003cbr\u003e6; male RA G1\/4 \/ female RB G1\/4: GPHF602,GPHF602D\u003cbr\u003e8; male RA G1\/4 \/ female RB G1\/4: GPHF802,GPHF802D\u003cbr\u003emain 8 \/ branch 6: GPKD8-602,GPKD8-602D\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997248336175,"sku":"SR20008LJ3G","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_dd5b687a-3913-4e6f-b28c-712e6a409c1c.jpg?v=1711390337"},{"product_id":"airtac-sr-regulatormini-type-sr20008lj4","title":"Airtac SR series: miniature pressure regulator - SR20008LJ4","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008LJ4 is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, an included kgf\/cm² and psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; kgf\/cm² and psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008LJ4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. no separate mass correction is calculated for pressure type L, gauge 4, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":48997253841199,"sku":"SR20008LJ4","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_5aaa0b6b-5378-4264-9ff9-fc831f5d126e.jpg?v=1711390363"},{"product_id":"airtac-sr-regulatormini-type-sr20006l4","title":"Airtac SR series: miniature pressure regulator - SR20006L4","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006L4 is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, an included kgf\/cm² and psi-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; kgf\/cm² and psi scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006L4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge 4, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":49006959788335,"sku":"SR20006L4","price":15.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_0a03e9bf-27b9-4d78-8782-6ceb5f124abf.jpg?v=1711469576"},{"product_id":"airtac-sr-regulatormini-type-sr20006lj1","title":"Airtac SR series: miniature pressure regulator - SR20006LJ1","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006LJ1 is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, an included MPa-scale pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePressure gauge included; MPa scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006LJ1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type L, gauge 1, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":49006969782575,"sku":"SR20006LJ1","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_08777ae8-9784-4f98-8109-71d84f0a438a.jpg?v=1711469627"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006n","title":"Airtac SR series: miniature pressure regulator - SR20006N","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006N is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575304388911,"sku":"SR20006N","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/7E98A8AD-594F-4A55-BBDF-547F80A41046.jpg?v=1778293371"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006ng","title":"Airtac SR series: miniature pressure regulator - SR20006NG","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006NG is an Airtac 200-series mini pressure regulator with G 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eG 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/8 ↔ male G1\/8: GBB0101\u003cbr\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G3\/8 ↔ male G1\/8: GBB0103\u003cbr\u003e4 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-01\u003cbr\u003e10: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D\u003cbr\u003e4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D\u003cbr\u003e6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D\u003cbr\u003e8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D\u003cbr\u003e12: GPC1201,GPC1201D,GPL1201,GPL1201D\u003cbr\u003e4; male RA G1\/8 \/ female RB G1\/8: GPHF401,GPHF401D\u003cbr\u003e6; male RA G1\/8 \/ female RB G1\/8: GPHF601,GPHF601D\u003cbr\u003e8; male RA G1\/8 \/ female RB G1\/8: GPHF801,GPHF801D\u003cbr\u003emain 6 \/ branch 4: GPKD6-401,GPKD6-401D\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575304421679,"sku":"SR20006NG","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_8dadadaf-20ab-4e66-a89b-2130f5f176ea.jpg?v=1751164238"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006nt","title":"Airtac SR series: miniature pressure regulator - SR20006NT","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006NT is an Airtac 200-series mini pressure regulator with NPT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006NT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/8: NBB1\/8-1\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT3\/8: NBB1\/8-3\/8\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/8\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NBKC5\/32-3\/32-1\/8\u003cbr\u003e1\/4 in: NBPC1\/4-1\/8,NPH1\/4-1\/8,NPHW1\/4-1\/8,NPLL1\/4-1\/8,NPZB1\/4-1\/8\u003cbr\u003e3\/8 in: NBPC3\/8-1\/8,NPLL3\/8-1\/8\u003cbr\u003e5\/16 in: NBPC5\/16-1\/8,NPH5\/16-1\/8,NPHW5\/16-1\/8,NPLL5\/16-1\/8,NPZB5\/16-1\/8\u003cbr\u003e5\/32 in: NBPC5\/32-1\/8,NPH5\/32-1\/8,NPHW5\/32-1\/8,NPLL5\/32-1\/8\u003cbr\u003e1\/4 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF1\/4-1\/8\u003cbr\u003e5\/16 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/16-1\/8\u003cbr\u003e5\/32 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/32-1\/8\u003cbr\u003emain 1\/4 \/ branches 5\/32 in: NPKD1\/4-5\/32-1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/4 in: NPC1\/4-1\/8,NPEB1\/4-1\/8,NPED1\/4-1\/8,NPL1\/4-1\/8,NPYB1\/4-1\/8\u003cbr\u003e3\/8 in: NPC3\/8-1\/8,NPEB3\/8-1\/8,NPED3\/8-1\/8,NPL3\/8-1\/8,NPYB3\/8-1\/8\u003cbr\u003e5\/16 in: NPC5\/16-1\/8,NPEB5\/16-1\/8,NPED5\/16-1\/8,NPL5\/16-1\/8,NPYB5\/16-1\/8\u003cbr\u003e5\/32 in: NPC5\/32-1\/8,NPEB5\/32-1\/8,NPED5\/32-1\/8,NPL5\/32-1\/8,NPYB5\/32-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NUE95A5\/32X3\/32-100BK,NUE95A5\/32X3\/32-100BR,NUE95A5\/32X3\/32-100BU,NUE95A5\/32X3\/32-100C,NUE95A5\/32X3\/32-100CB,NUE95A5\/32X3\/32-100CE,NUE95A5\/32X3\/32-100CG,NUE95A5\/32X3\/32-100CR,NUE95A5\/32X3\/32-100CY,NUE95A5\/32X3\/32-100GA,NUE95A5\/32X3\/32-100GE,NUE95A5\/32X3\/32-100GN,NUE95A5\/32X3\/32-100R,NUE95A5\/32X3\/32-100WH,NUE95A5\/32X3\/32-100Y,NUE95A5\/32X3\/32-250BK,NUE95A5\/32X3\/32-250BR,NUE95A5\/32X3\/32-250BU,NUE95A5\/32X3\/32-250C,NUE95A5\/32X3\/32-250CB,NUE95A5\/32X3\/32-250CE,NUE95A5\/32X3\/32-250CG,NUE95A5\/32X3\/32-250CR,NUE95A5\/32X3\/32-250CY,NUE95A5\/32X3\/32-250GA,NUE95A5\/32X3\/32-250GE,NUE95A5\/32X3\/32-250GN,NUE95A5\/32X3\/32-250R,NUE95A5\/32X3\/32-250WH,NUE95A5\/32X3\/32-250Y,NUE95A5\/32X3\/32-500BK,NUE95A5\/32X3\/32-500BR,NUE95A5\/32X3\/32-500BU,NUE95A5\/32X3\/32-500C,NUE95A5\/32X3\/32-500CB,NUE95A5\/32X3\/32-500CE,NUE95A5\/32X3\/32-500CG,NUE95A5\/32X3\/32-500CR,NUE95A5\/32X3\/32-500CY,NUE95A5\/32X3\/32-500GA,NUE95A5\/32X3\/32-500GE,NUE95A5\/32X3\/32-500GN,NUE95A5\/32X3\/32-500R,NUE95A5\/32X3\/32-500WH,NUE95A5\/32X3\/32-500Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eNBKC5\/32-3\/32-1\/8 specifies 3\/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube.\u003c\/p\u003e\n\u003cp\u003eThe listed NUE95A tubes serve IN and OUT only through a listed exact 5\/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5\/32-3\/32-1\/8, the supplier must also confirm 3\/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1\/8 in OD tube. These tubes are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eNUE95A5\/32X3\/32 is ether-based PU, Shore A95±2, with 5\/32 in OD × 3\/32 in ID and 1\/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit.\u003c\/p\u003e\n\u003cp\u003eIn NUE codes, 100\/250\/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575304487215,"sku":"SR20006NT","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_95e6be7d-2290-450c-a028-964367b5bcc7.jpg?v=1751164241"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006ln","title":"Airtac SR series: miniature pressure regulator - SR20006LN","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006LN is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006LN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575305077039,"sku":"SR20006LN","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_6cf9db19-ae8f-4d4d-91fb-586cf6880a86.jpg?v=1751164269"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006lng","title":"Airtac SR series: miniature pressure regulator - SR20006LNG","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006LNG is an Airtac 200-series mini pressure regulator with G 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eG 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006LNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/8 ↔ male G1\/8: GBB0101\u003cbr\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G3\/8 ↔ male G1\/8: GBB0103\u003cbr\u003e4 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-01\u003cbr\u003e10: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D\u003cbr\u003e4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D\u003cbr\u003e6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D\u003cbr\u003e8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D\u003cbr\u003e12: GPC1201,GPC1201D,GPL1201,GPL1201D\u003cbr\u003e4; male RA G1\/8 \/ female RB G1\/8: GPHF401,GPHF401D\u003cbr\u003e6; male RA G1\/8 \/ female RB G1\/8: GPHF601,GPHF601D\u003cbr\u003e8; male RA G1\/8 \/ female RB G1\/8: GPHF801,GPHF801D\u003cbr\u003emain 6 \/ branch 4: GPKD6-401,GPKD6-401D\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575305109807,"sku":"SR20006LNG","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_b16cae63-5fcf-485c-a7a9-bee2453e28a7.jpg?v=1751164272"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006lnt","title":"Airtac SR series: miniature pressure regulator - SR20006LNT","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006LNT is an Airtac 200-series mini pressure regulator with NPT 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006LNT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/8: NBB1\/8-1\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT3\/8: NBB1\/8-3\/8\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/8\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NBKC5\/32-3\/32-1\/8\u003cbr\u003e1\/4 in: NBPC1\/4-1\/8,NPH1\/4-1\/8,NPHW1\/4-1\/8,NPLL1\/4-1\/8,NPZB1\/4-1\/8\u003cbr\u003e3\/8 in: NBPC3\/8-1\/8,NPLL3\/8-1\/8\u003cbr\u003e5\/16 in: NBPC5\/16-1\/8,NPH5\/16-1\/8,NPHW5\/16-1\/8,NPLL5\/16-1\/8,NPZB5\/16-1\/8\u003cbr\u003e5\/32 in: NBPC5\/32-1\/8,NPH5\/32-1\/8,NPHW5\/32-1\/8,NPLL5\/32-1\/8\u003cbr\u003e1\/4 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF1\/4-1\/8\u003cbr\u003e5\/16 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/16-1\/8\u003cbr\u003e5\/32 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/32-1\/8\u003cbr\u003emain 1\/4 \/ branches 5\/32 in: NPKD1\/4-5\/32-1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/4 in: NPC1\/4-1\/8,NPEB1\/4-1\/8,NPED1\/4-1\/8,NPL1\/4-1\/8,NPYB1\/4-1\/8\u003cbr\u003e3\/8 in: NPC3\/8-1\/8,NPEB3\/8-1\/8,NPED3\/8-1\/8,NPL3\/8-1\/8,NPYB3\/8-1\/8\u003cbr\u003e5\/16 in: NPC5\/16-1\/8,NPEB5\/16-1\/8,NPED5\/16-1\/8,NPL5\/16-1\/8,NPYB5\/16-1\/8\u003cbr\u003e5\/32 in: NPC5\/32-1\/8,NPEB5\/32-1\/8,NPED5\/32-1\/8,NPL5\/32-1\/8,NPYB5\/32-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NUE95A5\/32X3\/32-100BK,NUE95A5\/32X3\/32-100BR,NUE95A5\/32X3\/32-100BU,NUE95A5\/32X3\/32-100C,NUE95A5\/32X3\/32-100CB,NUE95A5\/32X3\/32-100CE,NUE95A5\/32X3\/32-100CG,NUE95A5\/32X3\/32-100CR,NUE95A5\/32X3\/32-100CY,NUE95A5\/32X3\/32-100GA,NUE95A5\/32X3\/32-100GE,NUE95A5\/32X3\/32-100GN,NUE95A5\/32X3\/32-100R,NUE95A5\/32X3\/32-100WH,NUE95A5\/32X3\/32-100Y,NUE95A5\/32X3\/32-250BK,NUE95A5\/32X3\/32-250BR,NUE95A5\/32X3\/32-250BU,NUE95A5\/32X3\/32-250C,NUE95A5\/32X3\/32-250CB,NUE95A5\/32X3\/32-250CE,NUE95A5\/32X3\/32-250CG,NUE95A5\/32X3\/32-250CR,NUE95A5\/32X3\/32-250CY,NUE95A5\/32X3\/32-250GA,NUE95A5\/32X3\/32-250GE,NUE95A5\/32X3\/32-250GN,NUE95A5\/32X3\/32-250R,NUE95A5\/32X3\/32-250WH,NUE95A5\/32X3\/32-250Y,NUE95A5\/32X3\/32-500BK,NUE95A5\/32X3\/32-500BR,NUE95A5\/32X3\/32-500BU,NUE95A5\/32X3\/32-500C,NUE95A5\/32X3\/32-500CB,NUE95A5\/32X3\/32-500CE,NUE95A5\/32X3\/32-500CG,NUE95A5\/32X3\/32-500CR,NUE95A5\/32X3\/32-500CY,NUE95A5\/32X3\/32-500GA,NUE95A5\/32X3\/32-500GE,NUE95A5\/32X3\/32-500GN,NUE95A5\/32X3\/32-500R,NUE95A5\/32X3\/32-500WH,NUE95A5\/32X3\/32-500Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eNBKC5\/32-3\/32-1\/8 specifies 3\/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube.\u003c\/p\u003e\n\u003cp\u003eThe listed NUE95A tubes serve IN and OUT only through a listed exact 5\/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5\/32-3\/32-1\/8, the supplier must also confirm 3\/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1\/8 in OD tube. These tubes are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eNUE95A5\/32X3\/32 is ether-based PU, Shore A95±2, with 5\/32 in OD × 3\/32 in ID and 1\/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit.\u003c\/p\u003e\n\u003cp\u003eIn NUE codes, 100\/250\/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575305175343,"sku":"SR20006LNT","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_db256dc4-e38d-4159-a13e-0971c392a942.jpg?v=1751164274"},{"product_id":"airtac-sr-air-pressure-regulator-sr20008n","title":"Airtac SR series: miniature pressure regulator - SR20008N","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008N is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575305634095,"sku":"SR20008N","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_df4813bc-2c37-4816-8377-789237c7e086.jpg?v=1751164302"},{"product_id":"airtac-sr-air-pressure-regulator-sr20008ng","title":"Airtac SR series: miniature pressure regulator - SR20008NG","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008NG is an Airtac 200-series mini pressure regulator with G 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G1\/4 ↔ male G1\/4: GBB0202\u003cbr\u003emale G3\/8 ↔ male G1\/4: GBB0203\u003cbr\u003emale G1\/2 ↔ male G1\/4: GBB0204\u003cbr\u003emale G1\/4 ↔ female G1\/8: GBD0102\u003cbr\u003e6 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-02\u003cbr\u003e10 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: GBKC1075-02\u003cbr\u003e12 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: GBKC1209-02\u003cbr\u003e10: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D\u003cbr\u003e12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D\u003cbr\u003e4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D\u003cbr\u003e6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D\u003cbr\u003e8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D\u003cbr\u003e10; male RA G1\/4 \/ female RB G1\/4: GPHF1002,GPHF1002D\u003cbr\u003e6; male RA G1\/4 \/ female RB G1\/4: GPHF602,GPHF602D\u003cbr\u003e8; male RA G1\/4 \/ female RB G1\/4: GPHF802,GPHF802D\u003cbr\u003emain 8 \/ branch 6: GPKD8-602,GPKD8-602D\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575305699631,"sku":"SR20008NG","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_4eb2936c-49e4-47c9-9dc8-3fdb2eaf30dc.jpg?v=1751164305"},{"product_id":"airtac-sr-air-pressure-regulator-sr20008nt","title":"Airtac SR series: miniature pressure regulator - SR20008NT","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008NT is an Airtac 200-series mini pressure regulator with NPT 1\/4 main ports. Its current configuration has 0.05–0.9 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008NT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type (blank), gauge N, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/2 ↔ male NPT1\/4: NBB1\/4-1\/2\u003cbr\u003emale NPT1\/4 ↔ male NPT1\/4: NBB1\/4-1\/4\u003cbr\u003emale NPT3\/8 ↔ male NPT1\/4: NBB1\/4-3\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/4 ↔ female NPT1\/8: NBD1\/8-1\/4\u003cbr\u003e1\/2 × 1\/3 in: NBKC1\/2-1\/3-1\/4\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/4\u003cbr\u003e3\/8 × 1\/4 in: NBKC3\/8-1\/4-1\/4\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/4\u003cbr\u003e1\/2 in: NBPC1\/2-1\/4,NPLL1\/2-1\/4\u003cbr\u003e1\/4 in: NBPC1\/4-1\/4,NPH1\/4-1\/4,NPHW1\/4-1\/4,NPLL1\/4-1\/4,NPZB1\/4-1\/4\u003cbr\u003e3\/8 in: NBPC3\/8-1\/4,NPH3\/8-1\/4,NPHW3\/8-1\/4,NPLL3\/8-1\/4,NPZB3\/8-1\/4\u003cbr\u003e5\/16 in: NBPC5\/16-1\/4,NPH5\/16-1\/4,NPHW5\/16-1\/4,NPLL5\/16-1\/4,NPZB5\/16-1\/4\u003cbr\u003e1\/4 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF1\/4-1\/4\u003cbr\u003e3\/8 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF3\/8-1\/4\u003cbr\u003e5\/16 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF5\/16-1\/4\u003cbr\u003emain 5\/16 \/ branch 1\/4 in: NPKD5\/16-1\/4-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/2 in: NPC1\/2-1\/4,NPEB1\/2-1\/4,NPED1\/2-1\/4,NPL1\/2-1\/4,NPYB1\/2-1\/4\u003cbr\u003e1\/4 in: NPC1\/4-1\/4,NPEB1\/4-1\/4,NPED1\/4-1\/4,NPL1\/4-1\/4,NPYB1\/4-1\/4\u003cbr\u003e3\/8 in: NPC3\/8-1\/4,NPEB3\/8-1\/4,NPED3\/8-1\/4,NPL3\/8-1\/4,NPYB3\/8-1\/4\u003cbr\u003e5\/16 in: NPC5\/16-1\/4,NPEB5\/16-1\/4,NPED5\/16-1\/4,NPL5\/16-1\/4,NPYB5\/16-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575305765167,"sku":"SR20008NT","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_a76077ea-1f8e-478c-93f9-55df96ecea5d.jpg?v=1751164308"},{"product_id":"airtac-sr-air-pressure-regulator-sr20008ln","title":"Airtac SR series: miniature pressure regulator - SR20008LN","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008LN is an Airtac 200-series mini pressure regulator with PT 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008LN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BD male–female; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/4: BB0202,BB0202-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/4: BB0203,BB0203-S\u003cbr\u003emale PT1\/2 ↔ male PT1\/4: BB0204,BB0204-S\u003cbr\u003emale PT1\/4 ↔ female PT1\/8: BD0102,BD0102-S\u003cbr\u003e6 × 4: BKC0604-02,BKC0604-02-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-02,BKC0805-02-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-02,BKC0806-02-S\u003cbr\u003e10 × 6.5: BKC1065-02,BKC1065-02-S,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: BKC1075-02,BKC1075-02-S\u003cbr\u003e12 × 8: BKC1208-02,BKC1208-02-S,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: BKC1209-02,BKC1209-02-S\u003cbr\u003e10: BPC1002,BPOC1002,PC1002,PC1002-S,PC1002D,PC1002D-S,PEB1002,PEB1002-S,PEB1002D,PEB1002D-S,PED1002,PED1002-S,PED1002D,PED1002D-S,PH1002,PH1002-S,PH1002D,PH1002D-S,PHW1002,PHW1002-S,PHW1002D,PHW1002D-S,PL1002,PL1002-S,PL1002D,PL1002D-S,PLL1002,PLL1002-S,PLL1002D,PLL1002D-S,POC1002,POC1002-S,POC1002D,POC1002D-S,PYB1002,PYB1002-S,PYB1002D,PYB1002D-S,PZB1002,PZB1002-S,PZB1002D,PZB1002D-S\u003cbr\u003e12: BPC1202,PC1202,PC1202-S,PC1202D,PC1202D-S,PEB1202,PEB1202-S,PEB1202D,PEB1202D-S,PED1202,PED1202-S,PED1202D,PED1202D-S,PL1202,PL1202-S,PL1202D,PL1202D-S,PLL1202,PLL1202-S,PLL1202D,PLL1202D-S,POC1202,POC1202-S,POC1202D,POC1202D-S,PYB1202,PYB1202-S,PYB1202D,PYB1202D-S\u003cbr\u003e4: BPC402,PC402,PC402-S,PC402D,PC402D-S,PEB402,PEB402-S,PEB402D,PEB402D-S,PED402,PED402-S,PED402D,PED402D-S,PL402,PL402-S,PL402D,PL402D-S,PLL402,PLL402-S,PLL402D,PLL402D-S,POC402,POC402-S,POC402D,POC402D-S,PYB402,PYB402-S,PYB402D,PYB402D-S\u003cbr\u003e6: BPC602,BPOC602,PC602,PC602-S,PC602D,PC602D-S,PEB602,PEB602-S,PEB602D,PEB602D-S,PED602,PED602-S,PED602D,PED602D-S,PH602,PH602-S,PH602D,PH602D-S,PHW602,PHW602-S,PHW602D,PHW602D-S,PL602,PL602-S,PL602D,PL602D-S,PLL602,PLL602-S,PLL602D,PLL602D-S,POC602,POC602-S,POC602D,POC602D-S,PYB602,PYB602-S,PYB602D,PYB602D-S,PZB602,PZB602-S,PZB602D,PZB602D-S\u003cbr\u003e8: BPC802,BPOC802,PC802,PC802-S,PC802D,PC802D-S,PEB802,PEB802-S,PEB802D,PEB802D-S,PED802,PED802-S,PED802D,PED802D-S,PH802,PH802-S,PH802D,PH802D-S,PHW802,PHW802-S,PHW802D,PHW802D-S,PL802,PL802-S,PL802D,PL802D-S,PLL802,PLL802-S,PLL802D,PLL802D-S,POC802,POC802-S,POC802D,POC802D-S,PYB802,PYB802-S,PYB802D,PYB802D-S,PZB802,PZB802-S,PZB802D,PZB802D-S\u003cbr\u003e10; male RA PT1\/4 \/ female RB PT1\/4: PHF1002,PHF1002-S,PHF1002D,PHF1002D-S\u003cbr\u003e6; male RA PT1\/4 \/ female RB PT1\/4: PHF602,PHF602-S,PHF602D,PHF602D-S\u003cbr\u003e8; male RA PT1\/4 \/ female RB PT1\/4: PHF802,PHF802-S,PHF802D,PHF802D-S\u003cbr\u003emain 8 \/ branch 6: PKD8-602,PKD8-602-S,PKD8-602D,PKD8-602D-S\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575306191151,"sku":"SR20008LN","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_7932b190-fbda-4d6d-80b6-3c4ddd55aee9.jpg?v=1751164331"},{"product_id":"airtac-sr-air-pressure-regulator-sr20008lng","title":"Airtac SR series: miniature pressure regulator - SR20008LNG","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008LNG is an Airtac 200-series mini pressure regulator with G 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008LNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBD male–female; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G1\/4 ↔ male G1\/4: GBB0202\u003cbr\u003emale G3\/8 ↔ male G1\/4: GBB0203\u003cbr\u003emale G1\/2 ↔ male G1\/4: GBB0204\u003cbr\u003emale G1\/4 ↔ female G1\/8: GBD0102\u003cbr\u003e6 × 4: GBKC0604-02,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-02,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-02\u003cbr\u003e10 × 6.5: GBKC1065-02,UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e10 × 7.5 or 8: GBKC1075-02\u003cbr\u003e12 × 8: GBKC1208-02,UE95A120080100MBU,US98A120080100MBU\u003cbr\u003e12 × 9 or 10: GBKC1209-02\u003cbr\u003e10: GBPC1002,GPC1002,GPC1002D,GPEB1002,GPEB1002D,GPED1002,GPED1002D,GPH1002,GPH1002D,GPHW1002,GPHW1002D,GPL1002,GPL1002D,GPLL1002,GPLL1002D,GPYB1002,GPYB1002D,GPZB1002,GPZB1002D\u003cbr\u003e12: GBPC1202,GPC1202,GPC1202D,GPEB1202,GPEB1202D,GPED1202,GPED1202D,GPL1202,GPL1202D,GPLL1202,GPLL1202D,GPYB1202,GPYB1202D\u003cbr\u003e4: GBPC402,GPC402-M,GPC402D-M,GPEB402,GPEB402D,GPED402,GPED402D,GPL402-M,GPL402D-M,GPLL402,GPLL402D,GPYB402,GPYB402D\u003cbr\u003e6: GBPC602,GPC602,GPC602D,GPEB602,GPEB602D,GPED602,GPED602D,GPH602,GPH602D,GPHW602,GPHW602D,GPL602,GPL602D,GPLL602,GPLL602D,GPYB602,GPYB602D,GPZB602,GPZB602D\u003cbr\u003e8: GBPC802,GPC802,GPC802D,GPEB802,GPEB802D,GPED802,GPED802D,GPH802,GPH802D,GPHW802,GPHW802D,GPL802,GPL802D,GPLL802,GPLL802D,GPYB802,GPYB802D,GPZB802,GPZB802D\u003cbr\u003e10; male RA G1\/4 \/ female RB G1\/4: GPHF1002,GPHF1002D\u003cbr\u003e6; male RA G1\/4 \/ female RB G1\/4: GPHF602,GPHF602D\u003cbr\u003e8; male RA G1\/4 \/ female RB G1\/4: GPHF802,GPHF802D\u003cbr\u003emain 8 \/ branch 6: GPKD8-602,GPKD8-602D\u003cbr\u003e4 × 2.5: UE95A040025100MBU,US98A040025100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575306223919,"sku":"SR20008LNG","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_632ba286-a00c-4e4d-a3d6-5be63fae0307.jpg?v=1751164334"},{"product_id":"airtac-sr-air-pressure-regulator-sr20008lnt","title":"Airtac SR series: miniature pressure regulator - SR20008LNT","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20008LNT is an Airtac 200-series mini pressure regulator with NPT 1\/4 main ports. Its current configuration has 0.03–0.4 MPa adjustment, an included mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — bracket\u003c\/td\u003e\n\u003ctd\u003eBracket included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20008LNT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the reference is without a bracket (J); no bracket-mass adjustment has been made for the current mounting option; no separate mass correction is calculated for pressure type L, gauge N, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded with this model\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/4 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/4 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBD male–female; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/2 ↔ male NPT1\/4: NBB1\/4-1\/2\u003cbr\u003emale NPT1\/4 ↔ male NPT1\/4: NBB1\/4-1\/4\u003cbr\u003emale NPT3\/8 ↔ male NPT1\/4: NBB1\/4-3\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/4 ↔ female NPT1\/8: NBD1\/8-1\/4\u003cbr\u003e1\/2 × 1\/3 in: NBKC1\/2-1\/3-1\/4\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/4\u003cbr\u003e3\/8 × 1\/4 in: NBKC3\/8-1\/4-1\/4\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/4\u003cbr\u003e1\/2 in: NBPC1\/2-1\/4,NPLL1\/2-1\/4\u003cbr\u003e1\/4 in: NBPC1\/4-1\/4,NPH1\/4-1\/4,NPHW1\/4-1\/4,NPLL1\/4-1\/4,NPZB1\/4-1\/4\u003cbr\u003e3\/8 in: NBPC3\/8-1\/4,NPH3\/8-1\/4,NPHW3\/8-1\/4,NPLL3\/8-1\/4,NPZB3\/8-1\/4\u003cbr\u003e5\/16 in: NBPC5\/16-1\/4,NPH5\/16-1\/4,NPHW5\/16-1\/4,NPLL5\/16-1\/4,NPZB5\/16-1\/4\u003cbr\u003e1\/4 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF1\/4-1\/4\u003cbr\u003e3\/8 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF3\/8-1\/4\u003cbr\u003e5\/16 in; male RA NPT1\/4 \/ female RB NPT1\/4: NPHF5\/16-1\/4\u003cbr\u003emain 5\/16 \/ branch 1\/4 in: NPKD5\/16-1\/4-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/2 in: NPC1\/2-1\/4,NPEB1\/2-1\/4,NPED1\/2-1\/4,NPL1\/2-1\/4,NPYB1\/2-1\/4\u003cbr\u003e1\/4 in: NPC1\/4-1\/4,NPEB1\/4-1\/4,NPED1\/4-1\/4,NPL1\/4-1\/4,NPYB1\/4-1\/4\u003cbr\u003e3\/8 in: NPC3\/8-1\/4,NPEB3\/8-1\/4,NPED3\/8-1\/4,NPL3\/8-1\/4,NPYB3\/8-1\/4\u003cbr\u003e5\/16 in: NPC5\/16-1\/4,NPEB5\/16-1\/4,NPED5\/16-1\/4,NPL5\/16-1\/4,NPYB5\/16-1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575306289455,"sku":"SR20008LNT","price":12.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_3e3aef1d-8645-4ff4-a7ea-81ff28ff8757.jpg?v=1751164337"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006jn","title":"Airtac SR series: miniature pressure regulator - SR20006JN","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006JN is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006JN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge N, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575306846511,"sku":"SR20006JN","price":12.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/C88A3FA1-80F6-460C-87E9-FB7394103BCB.jpg?v=1778291961"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006jng","title":"Airtac SR series: miniature pressure regulator - SR20006JNG","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006JNG is an Airtac 200-series mini pressure regulator with G 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eG 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006JNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge N, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/8 ↔ male G1\/8: GBB0101\u003cbr\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G3\/8 ↔ male G1\/8: GBB0103\u003cbr\u003e4 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-01\u003cbr\u003e10: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D\u003cbr\u003e4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D\u003cbr\u003e6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D\u003cbr\u003e8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D\u003cbr\u003e12: GPC1201,GPC1201D,GPL1201,GPL1201D\u003cbr\u003e4; male RA G1\/8 \/ female RB G1\/8: GPHF401,GPHF401D\u003cbr\u003e6; male RA G1\/8 \/ female RB G1\/8: GPHF601,GPHF601D\u003cbr\u003e8; male RA G1\/8 \/ female RB G1\/8: GPHF801,GPHF801D\u003cbr\u003emain 6 \/ branch 4: GPKD6-401,GPKD6-401D\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575306912047,"sku":"SR20006JNG","price":12.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_ab3e0d9f-df27-4492-a9d8-3e9ecd25e5c8.jpg?v=1751164370"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006jnt","title":"Airtac SR series: miniature pressure regulator - SR20006JNT","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006JNT is an Airtac 200-series mini pressure regulator with NPT 1\/8 main ports. Its current configuration has 0.05–0.9 MPa adjustment, no mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — pressure\u003c\/td\u003e\n\u003ctd\u003eStandard type; 0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003ctd\u003eNPT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006JNT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eNPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.05–0.9 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type (blank), gauge N, thread T. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × NPT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s NPT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its NPT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): NBB male–male; NBKC compression fitting; NBPC metal straight; NPC straight; NPEB branch tee; NPED run tee; NPH banjo elbow; NPHF female branch banjo; NPHW twin banjo; NPKD reducing distribution fitting; NPL elbow; NPLL extended elbow; NPYB Y; NPZB cross; NUE polyurethane tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT (discontinued)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale NPT1\/8 ↔ male NPT1\/4: NBB1\/8-1\/4\u003cbr\u003emale NPT1\/8 ↔ male NPT1\/8: NBB1\/8-1\/8\u003cbr\u003emale NPT1\/8 ↔ male NPT3\/8: NBB1\/8-3\/8\u003cbr\u003e1\/4 × 5\/32 in: NBKC1\/4-5\/32-1\/8\u003cbr\u003e5\/16 × 1\/5 in: NBKC5\/16-1\/5-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NBKC5\/32-3\/32-1\/8\u003cbr\u003e1\/4 in: NBPC1\/4-1\/8,NPH1\/4-1\/8,NPHW1\/4-1\/8,NPLL1\/4-1\/8,NPZB1\/4-1\/8\u003cbr\u003e3\/8 in: NBPC3\/8-1\/8,NPLL3\/8-1\/8\u003cbr\u003e5\/16 in: NBPC5\/16-1\/8,NPH5\/16-1\/8,NPHW5\/16-1\/8,NPLL5\/16-1\/8,NPZB5\/16-1\/8\u003cbr\u003e5\/32 in: NBPC5\/32-1\/8,NPH5\/32-1\/8,NPHW5\/32-1\/8,NPLL5\/32-1\/8\u003cbr\u003e1\/4 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF1\/4-1\/8\u003cbr\u003e5\/16 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/16-1\/8\u003cbr\u003e5\/32 in; male RA NPT1\/8 \/ female RB NPT1\/8: NPHF5\/32-1\/8\u003cbr\u003emain 1\/4 \/ branches 5\/32 in: NPKD1\/4-5\/32-1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003e1\/4 in: NPC1\/4-1\/8,NPEB1\/4-1\/8,NPED1\/4-1\/8,NPL1\/4-1\/8,NPYB1\/4-1\/8\u003cbr\u003e3\/8 in: NPC3\/8-1\/8,NPEB3\/8-1\/8,NPED3\/8-1\/8,NPL3\/8-1\/8,NPYB3\/8-1\/8\u003cbr\u003e5\/16 in: NPC5\/16-1\/8,NPEB5\/16-1\/8,NPED5\/16-1\/8,NPL5\/16-1\/8,NPYB5\/16-1\/8\u003cbr\u003e5\/32 in: NPC5\/32-1\/8,NPEB5\/32-1\/8,NPED5\/32-1\/8,NPL5\/32-1\/8,NPYB5\/32-1\/8\u003cbr\u003e5\/32 × 3\/32 in: NUE95A5\/32X3\/32-100BK,NUE95A5\/32X3\/32-100BR,NUE95A5\/32X3\/32-100BU,NUE95A5\/32X3\/32-100C,NUE95A5\/32X3\/32-100CB,NUE95A5\/32X3\/32-100CE,NUE95A5\/32X3\/32-100CG,NUE95A5\/32X3\/32-100CR,NUE95A5\/32X3\/32-100CY,NUE95A5\/32X3\/32-100GA,NUE95A5\/32X3\/32-100GE,NUE95A5\/32X3\/32-100GN,NUE95A5\/32X3\/32-100R,NUE95A5\/32X3\/32-100WH,NUE95A5\/32X3\/32-100Y,NUE95A5\/32X3\/32-250BK,NUE95A5\/32X3\/32-250BR,NUE95A5\/32X3\/32-250BU,NUE95A5\/32X3\/32-250C,NUE95A5\/32X3\/32-250CB,NUE95A5\/32X3\/32-250CE,NUE95A5\/32X3\/32-250CG,NUE95A5\/32X3\/32-250CR,NUE95A5\/32X3\/32-250CY,NUE95A5\/32X3\/32-250GA,NUE95A5\/32X3\/32-250GE,NUE95A5\/32X3\/32-250GN,NUE95A5\/32X3\/32-250R,NUE95A5\/32X3\/32-250WH,NUE95A5\/32X3\/32-250Y,NUE95A5\/32X3\/32-500BK,NUE95A5\/32X3\/32-500BR,NUE95A5\/32X3\/32-500BU,NUE95A5\/32X3\/32-500C,NUE95A5\/32X3\/32-500CB,NUE95A5\/32X3\/32-500CE,NUE95A5\/32X3\/32-500CG,NUE95A5\/32X3\/32-500CR,NUE95A5\/32X3\/32-500CY,NUE95A5\/32X3\/32-500GA,NUE95A5\/32X3\/32-500GE,NUE95A5\/32X3\/32-500GN,NUE95A5\/32X3\/32-500R,NUE95A5\/32X3\/32-500WH,NUE95A5\/32X3\/32-500Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eNPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.05–0.9 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. NBPC\/compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eNBKC5\/32-3\/32-1\/8 specifies 3\/32 in ID in its dimension row, but the selection matrix differs. Confirm that ID with the supplier before selecting the tube.\u003c\/p\u003e\n\u003cp\u003eThe listed NUE95A tubes serve IN and OUT only through a listed exact 5\/32 in OD connection; they do not connect directly to an NPT thread. For NBKC5\/32-3\/32-1\/8, the supplier must also confirm 3\/32 in ID. Do not substitute 4 mm, 3.2 mm, 3 mm or 1\/8 in OD tube. These tubes are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eNUE95A5\/32X3\/32 is ether-based PU, Shore A95±2, with 5\/32 in OD × 3\/32 in ID and 1\/32 in wall. Working pressure is 145 psi at 73°F; 363 psi is burst pressure, not a working rating. Temperature range: −40–158°F; minimum bend radius: 8 mm. Derate with increasing temperature and obey every stricter unit, fitting and tube limit.\u003c\/p\u003e\n\u003cp\u003eIn NUE codes, 100\/250\/500 after the hyphen are coil lengths in feet, not metres. Colours: BU blue, BK black, GE orange, C clear, WH white, CB clear blue, R red, Y yellow, GA gray, GN green, BR brown, CR clear red, CG clear green, CY clear yellow, CE clear orange. Match the complete length-and-colour code. Current lifecycle and supply of these catalog-listed tubes are unverified; confirm the exact item or an approved replacement before ordering.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575307436335,"sku":"SR20006JNT","price":12.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_67b4e142-dda5-4a1d-beba-72b151d24183.jpg?v=1751164374"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006ljn","title":"Airtac SR series: miniature pressure regulator - SR20006LJN","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006LJN is an Airtac 200-series mini pressure regulator with PT 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank — thread\u003c\/td\u003e\n\u003ctd\u003ePT thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006LJN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003ePT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type L, gauge N, thread (blank). Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × PT 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s PT1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its PT1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): BB male–male; BKC compression fitting; BPC metal straight; BPOC metal straight; PC straight; PEB branch tee; PED run tee; PH banjo elbow; PHF female branch banjo; PHW twin banjo; PKD reducing distribution fitting; PL elbow; PLL extended elbow; POC round straight; PYB Y; PZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale PT1\/8 ↔ male PT1\/8: BB0101,BB0101-S\u003cbr\u003emale PT1\/4 ↔ male PT1\/8: BB0102,BB0102-S\u003cbr\u003emale PT3\/8 ↔ male PT1\/8: BB0103,BB0103-S\u003cbr\u003e4 × 2.5: BKC0425-01,BKC0425-01-S,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: BKC0604-01,BKC0604-01-S,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: BKC0805-01,BKC0805-01-S,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: BKC0806-01,BKC0806-01-S\u003cbr\u003e10: BPC1001,PC1001,PC1001-S,PC1001D,PC1001D-S,PEB1001,PEB1001-S,PEB1001D,PEB1001D-S,PED1001,PED1001-S,PED1001D,PED1001D-S,PL1001,PL1001-S,PL1001D,PL1001D-S,PLL1001,PLL1001-S,PLL1001D,PLL1001D-S,POC1001,POC1001-S,POC1001D,POC1001D-S,PYB1001,PYB1001-S,PYB1001D,PYB1001D-S\u003cbr\u003e4: BPC401,BPOC401,PC401,PC401-M,PC401-S,PC401D,PC401D-M,PC401D-S,PEB401,PEB401-S,PEB401D,PEB401D-S,PED401,PED401-S,PED401D,PED401D-S,PH401,PH401-S,PH401D,PH401D-S,PHW401,PHW401-S,PHW401D,PHW401D-S,PL401,PL401-M,PL401-S,PL401D,PL401D-M,PL401D-S,PLL401,PLL401-S,PLL401D,PLL401D-S,POC401,POC401-S,POC401D,POC401D-S,PYB401,PYB401-S,PYB401D,PYB401D-S\u003cbr\u003e6: BPC601,BPOC601,PC601,PC601-M,PC601-S,PC601D,PC601D-M,PC601D-S,PEB601,PEB601-S,PEB601D,PEB601D-S,PED601,PED601-S,PED601D,PED601D-S,PH601,PH601-S,PH601D,PH601D-S,PHW601,PHW601-S,PHW601D,PHW601D-S,PL601,PL601-M,PL601-S,PL601D,PL601D-M,PL601D-S,PLL601,PLL601-S,PLL601D,PLL601D-S,POC601,POC601-S,POC601D,POC601D-S,PYB601,PYB601-S,PYB601D,PYB601D-S,PZB601,PZB601-S,PZB601D,PZB601D-S\u003cbr\u003e8: BPC801,BPOC801,PC801,PC801-S,PC801D,PC801D-S,PEB801,PEB801-S,PEB801D,PEB801D-S,PED801,PED801-S,PED801D,PED801D-S,PH801,PH801-S,PH801D,PH801D-S,PHW801,PHW801-S,PHW801D,PHW801D-S,PL801,PL801-S,PL801D,PL801D-S,PLL801,PLL801-S,PLL801D,PLL801D-S,POC801,POC801-S,POC801D,POC801D-S,PYB801,PYB801-S,PYB801D,PYB801D-S,PZB801,PZB801-S,PZB801D,PZB801D-S\u003cbr\u003e12: PC1201,PC1201-S,PC1201D,PC1201D-S,PL1201,PL1201-S,PL1201D,PL1201D-S\u003cbr\u003e4; male RA PT1\/8 \/ female RB PT1\/8: PHF401,PHF401-S,PHF401D,PHF401D-S\u003cbr\u003e6; male RA PT1\/8 \/ female RB PT1\/8: PHF601,PHF601-S,PHF601D,PHF601D-S\u003cbr\u003e8; male RA PT1\/8 \/ female RB PT1\/8: PHF801,PHF801-S,PHF801D,PHF801D-S\u003cbr\u003emain 6 \/ branch 4: PKD6-401,PKD6-401-S,PKD6-401D,PKD6-401D-S\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003ePHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal BPC\/BPOC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575307862319,"sku":"SR20006LJN","price":12.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_8d6ca448-8b1b-439a-ae31-6c6a4f318048.jpg?v=1751164400"},{"product_id":"airtac-sr-air-pressure-regulator-sr20006ljng","title":"Airtac SR series: miniature pressure regulator - SR20006LJNG","description":"\u003cdiv style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-family:Arial,sans-serif;font-size:15px;line-height:1.8;color:#253442;box-sizing:border-box\"\u003e\n\u003cp style=\"margin:12px 0\"\u003eSpecifications: SR20006LJNG is an Airtac 200-series mini pressure regulator with G 1\/8 main ports. Its current configuration has 0.03–0.4 MPa adjustment, no mounting bracket, no pressure gauge.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eProduct Catalog\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/airtac-sr-ok213.pdf?v=1780229008\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;max-width:100%;box-sizing:border-box;padding:12px 16px;border-radius:4px;background:#0067a5;color:#ffffff;text-decoration:none!important;font-weight:600;line-height:1.5\"\u003eDownload Airtac Product Catalog (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eModel Code Explained\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eCode\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMeaning for this model\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR\u003c\/td\u003e\n\u003ctd\u003emini pressure regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e200 size series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003eG 1\/8 main connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003ctd\u003eLow-pressure type; 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003eWithout bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eWithout pressure gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eG thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR20006LJNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking medium\u003c\/td\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain port\u003c\/td\u003e\n\u003ctd\u003eG 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure regulation range\u003c\/td\u003e\n\u003ctd\u003e0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e1.5 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−20–70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eWeight Reference\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eReference weight\u003c\/td\u003e\n\u003ctd\u003e169 g; 2022 Chinese comprehensive catalog, printed page 300 \/ PDF page 301; published reference SR200-08J. Assigned as an estimated reference for the current configuration, not a measured product or shipping weight. the current 06 port code shares the same-size 08 port reference; no separate mass correction is calculated for pressure type L, gauge N, thread G. Actual supplied-product weight may differ.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFeatures and Operation\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThis compact regulator provides reliable adjustment for a standalone pipeline installation, using a panel mounting thread or bracket. A low-pressure option limits the maximum adjustable output to 0.4 MPa.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eExternal and Mounting Dimensions\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eDimensions are in millimeters unless a thread or other unit is shown. Lettered entries follow the catalog drawing; local callouts must not be combined into an invented length × width × height. Optional brackets and gauges are shown for reference only when their omission code is selected.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront width\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole pitch\u003c\/td\u003e\n\u003ctd\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local callout\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot width\u003c\/td\u003e\n\u003ctd\u003e5.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront local vertical callout\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort-axis callout\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower local callout\u003c\/td\u003e\n\u003ctd\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocked-height callout\u003c\/td\u003e\n\u003ctd\u003e74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob diameter\u003c\/td\u003e\n\u003ctd\u003eØ28 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel mounting thread\u003c\/td\u003e\n\u003ctd\u003eM30×1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket thickness\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody depth\u003c\/td\u003e\n\u003ctd\u003e38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide local callout\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge projection reference\u003c\/td\u003e\n\u003ctd\u003e(51.5) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge diameter\u003c\/td\u003e\n\u003ctd\u003eØ42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge taps\u003c\/td\u003e\n\u003ctd\u003e2 × 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain ports\u003c\/td\u003e\n\u003ctd\u003e2 × G 1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0;padding:12px;border-left:3px solid #0067a5;background:#eef3f6;line-height:1.65\"\u003e\u003cstrong\u003eFor detailed product dimensions and mounting drawings, please download and refer to the PDF catalog.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eAccessories and Installation\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\u003ctr\u003e\n\u003ctd\u003eMounting bracket\u003c\/td\u003e\n\u003ctd\u003eOmitted by J; do not count a bracket as included\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eFlow \/ Performance Characteristics\u003c\/h3\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eChart specimen\u003c\/td\u003e\n\u003ctd\u003eSR20006; the 08 port is not separately plotted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart horizontal axis\u003c\/td\u003e\n\u003ctd\u003eInlet pressure, 0–1.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure-chart vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0.18–0.22 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow horizontal axis\u003c\/td\u003e\n\u003ctd\u003eAir flow, 0–1000 L\/min; 200 L\/min labels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow vertical axis\u003c\/td\u003e\n\u003ctd\u003eOutlet pressure, 0–0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow condition\u003c\/td\u003e\n\u003ctd\u003eInlet pressure 0.7 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0\"\u003eThese values describe the printed chart axes and conditions. An axis limit is not a rated flow or a guaranteed tolerance. Curves for a representative port or configuration are series references; use the original PDF to read the plotted relationships.\u003c\/p\u003e\n\u003ch3 style=\"margin:28px 0 12px;padding-bottom:7px;font-size:19px;line-height:1.4;color:#172f42;border-bottom:1px solid #d8e1e7\"\u003eSeries Ordering Options\u003c\/h3\u003e\n\u003cp style=\"margin:12px 0\"\u003eThe following choices belong to the catalog family. They are alternatives, not a list of everything included with the current model.\u003c\/p\u003e\n\u003cdiv style=\"max-width:100%;min-width:0;overflow-x:auto;margin:12px 0\"\u003e\u003ctable border=\"1\" cellpadding=\"8\" rules=\"all\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;font-size:14px;line-height:1.6;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"width:38%\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody style=\"vertical-align:top\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-port choices\u003c\/td\u003e\n\u003ctd\u003e06: 1\/8; 08: 1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure options\u003c\/td\u003e\n\u003ctd\u003eBlank: 0.05–0.9 MPa; L: 0.03–0.4 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBracket\u003c\/td\u003e\n\u003ctd\u003eBlank: included; J: omitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003eN: omitted; 1: MPa, 2: psi, 3: bar, 4: kgf\/cm² and psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003eBlank: PT; G: G; T: NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale \/ thread combination\u003c\/td\u003e\n\u003ctd\u003e1 or 4: PT thread; 2: NPT thread with T; 3: G thread with G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003csection data-airtac-accessory=\"sr72-resume-20261016\" style=\"max-width:100%;min-width:0;overflow-wrap:anywhere;white-space:normal;font-size:15px;line-height:1.7;color:#253442;box-sizing:border-box\"\u003e\u003ch3 style=\"color:#172f42;font-size:19px;line-height:1.4;border-bottom:1px solid #d8e1e7;margin:22px 0 10px\"\u003eOptional Piping Accessories\u003c\/h3\u003e\n\u003cp\u003eIN = the SR regulator’s G1\/8 female supply-air inlet on the left in the catalog drawing; OUT = its G1\/8 female regulated-air outlet on the right. Match these separate connections and follow the actual body’s IN → OUT markings; do not bridge or bypass the regulator. Multiple keys retain each use. Tube OD is mm (in = inches); compression\/tubing show OD × ID. These piping accessories are optional and ordered separately.\u003c\/p\u003e\n\u003cp\u003eCode-prefix uses (match the longest listed family prefix): GBB male–male; GBKC compression fitting; GBPC metal straight; GPC straight; GPEB branch tee; GPED run tee; GPH banjo elbow; GPHF female branch banjo; GPHW twin banjo; GPKD reducing distribution fitting; GPL elbow; GPLL extended elbow; GPYB Y; GPZB cross; UE PU tube; US PU tube.\u003c\/p\u003e\n\u003ctable border=\"1\" rules=\"all\" cellpadding=\"8\" style=\"margin:0!important;width:100%;max-width:100%;table-layout:fixed;border-collapse:collapse;border-color:#d8e1e7;overflow-wrap:anywhere\"\u003e\n\u003cthead style=\"background:#eef3f6;text-align:left\"\u003e\u003ctr\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top;width:23%\"\u003eUse\u003c\/th\u003e\n\u003cth style=\"font-size:14px!important;vertical-align:top\"\u003eSize \/ complete codes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003eIN,OUT\u003c\/td\u003e\n\u003ctd style=\"font-size:14px!important;vertical-align:top\"\u003emale G1\/8 ↔ male G1\/8: GBB0101\u003cbr\u003emale G1\/4 ↔ male G1\/8: GBB0102\u003cbr\u003emale G3\/8 ↔ male G1\/8: GBB0103\u003cbr\u003e4 × 2.5: GBKC0425-01,UE95A040025100MBU,US98A040025100MBU\u003cbr\u003e6 × 4: GBKC0604-01,UE95A060040100MBU,US98A060040100MBU\u003cbr\u003e8 × 5: GBKC0805-01,UE95A080050100MBU,US98A080050100MBU\u003cbr\u003e8 × 5.5 or 6: GBKC0806-01\u003cbr\u003e10: GBPC1001,GPC1001,GPC1001D,GPEB1001,GPEB1001D,GPED1001,GPED1001D,GPL1001,GPL1001D,GPLL1001,GPLL1001D,GPYB1001,GPYB1001D\u003cbr\u003e4: GBPC401,GPC401-M,GPC401D-M,GPEB401,GPEB401D,GPED401,GPED401D,GPH401,GPH401D,GPHW401,GPHW401D,GPL401-M,GPL401D-M,GPLL401,GPLL401D,GPYB401,GPYB401D\u003cbr\u003e6: GBPC601,GPC601,GPC601-M,GPC601D,GPC601D-M,GPEB601,GPEB601D,GPED601,GPED601D,GPH601,GPH601D,GPHW601,GPHW601D,GPL601,GPL601-M,GPL601D,GPL601D-M,GPLL601,GPLL601D,GPYB601,GPYB601D,GPZB601,GPZB601D\u003cbr\u003e8: GBPC801,GPC801,GPC801D,GPEB801,GPEB801D,GPED801,GPED801D,GPH801,GPH801D,GPHW801,GPHW801D,GPL801,GPL801D,GPLL801,GPLL801D,GPYB801,GPYB801D,GPZB801,GPZB801D\u003cbr\u003e12: GPC1201,GPC1201D,GPL1201,GPL1201D\u003cbr\u003e4; male RA G1\/8 \/ female RB G1\/8: GPHF401,GPHF401D\u003cbr\u003e6; male RA G1\/8 \/ female RB G1\/8: GPHF601,GPHF601D\u003cbr\u003e8; male RA G1\/8 \/ female RB G1\/8: GPHF801,GPHF801D\u003cbr\u003emain 6 \/ branch 4: GPKD6-401,GPKD6-401D\u003cbr\u003e10 × 6.5: UE95A100065100MBU,US98A100065100MBU\u003cbr\u003e12 × 8: UE95A120080100MBU,US98A120080100MBU\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese optional connections and tubes are ordered separately for the SR regulator. Match PT\/G\/NPT exactly and use the specified thread seal or face gasket. IN and OUT are female ports and require their own matching male connections. Follow the body’s normal IN → OUT markings; do not bridge or bypass the regulator. Keep the main air lines separate from the gauge connections and mounting features.\u003c\/p\u003e\n\u003cp\u003eMatch tube OD and compression OD\/ID; metric and inch sizes are not interchangeable. Use suitable soft nylon\/PU tube and check seating, clearance, bends, support and required flow. Tighten compression bodies by the hex, not tube nuts. Where listed, a D suffix means black, blank means grey, -M means miniature, and -S applies only to the specified 304 stainless parts.\u003c\/p\u003e\n\u003cp\u003eGPHF fittings use male RA at the selected IN or OUT port; female RB requires its own matching male thread and seal and is not a tube socket. Match both adapter ends to their separate mating parts. Keep every extra branch on its assigned side of the regulator; do not connect IN to OUT around the regulator or use a mounting feature as an air connection.\u003c\/p\u003e\n\u003cp\u003eThe regulator’s maximum inlet pressure is 1.0 MPa; this configuration’s adjustable outlet range is 0.03–0.4 MPa. Keep actual IN pressure within the inlet limit and actual OUT pressure within the selected regulation range and downstream limits. Every fitting, seal and tube must satisfy its own local pressure rating during operation, adjustment and pressure changes. The 1.5 MPa proof pressure is not a continuous working rating; the 1 MPa inlet limit does not mean the outlet can be regulated to 1 MPa.\u003c\/p\u003e\n\u003cp\u003eUse within −20–70°C and every stricter accessory limit. Confirm that fittings, seals, tubing and downstream equipment are compatible with the actual air contaminants and any upstream lubricant or additives. These are main-air connections, not gauge or process-liquid lines. This regulator does not add filtration, lubrication or drying, and does not establish oil-free air or a dew-point rating. These selections do not establish liquid or vacuum service for the listed air-piping accessories.\u003c\/p\u003e\n\u003cp\u003eConfirm the required inlet supply, pressure drop and installed flow at the chosen outlet setting. The printed flow chart uses SR20006 at 0.7 MPa inlet pressure; the 1\/4 in 08 port is not separately plotted. Its 1000 L\/min axis limit is not a rated flow or a guaranteed installed operating point. Use the original plotted relationships and verify actual circuit requirements rather than treating a chart boundary as capacity.\u003c\/p\u003e\n\u003cp\u003eStandard push-in fittings: ≤1 MPa, −20–70°C. Metal GBPC: ≤0.9 MPa; compression fittings\/thread adapters: ≤1 MPa. The listed metal push-in, compression and adapter groups have a 0–150°C component range, so a path using them is limited to 0–70°C or narrower with this regulator. A lower-rated fitting at IN requires a correspondingly lower inlet pressure; the unit’s 1 MPa inlet rating does not raise any accessory rating. Confirm compatibility with the actual air contaminants and lubricant.\u003c\/p\u003e\n\u003cp\u003eUS98A\/UE95A examples are separately ordered blue 100 m metric PU coils rated 1 MPa at 23°C. US98A: −20–70°C; UE95A: −40–70°C. Match the assigned air connection’s required OD\/ID and derate as temperature rises within all unit, fitting and tube limits; 1 MPa is not assured throughout. Use inch tube where the selected connection requires it; metric tube is not a substitute. These examples are assigned only to the main air lines.\u003c\/p\u003e\n\u003cp\u003eWhen J is selected, the mounting bracket is omitted; without J, it is included as stated in the original specification. Support the regulator and connected piping. M30×1.5 is the panel-mounting thread, not an air port. Gauge code N omits the gauge. For the included-gauge configurations, codes 1 and 4 select MPa and dual kgf\/cm²\/psi scales respectively, with PT main threads; code 2 selects psi with T\/NPT, and code 3 selects bar with G main threads. These main-thread and scale choices do not establish the thread standard of the two nominal 1\/8 gauge tappings. No listed item is assigned to those gauge tappings or to a mounting or drain feature.\u003c\/p\u003e\n\u003cp\u003eItems marked discontinued are historical service references, not current standard recommendations. Confirm availability or a manufacturer-approved replacement. An unmarked catalogue entry does not promise current production, stock or delivery.\u003c\/p\u003e\u003c\/section\u003e","brand":"Airtac-1","offers":[{"title":"Default Title","offer_id":51575307895087,"sku":"SR20006LJNG","price":12.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/files\/sr_2bc6034b-bbd0-435f-b0b3-e0ea54ab9c1f.jpg?v=1751164403"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/2336\/1327\/collections\/sr_8d5ba0d6-69cd-4dcc-a6d6-2eed58909873.jpg?v=1784016360","url":"https:\/\/www.airtacs.com\/collections\/sr72.oembed?page=3","provider":"Airtac","version":"1.0","type":"link"}