474 products

LGC Series Cross Roller Guide

High Rigidity | High Precision | Non-Circulating Type
  • Product Features
  • Set Ordering
  • Component Ordering
  • Installation Data

Product Overview

The LGC series is a high-rigidity, high-precision non-circulating linear motion guide. It utilizes precision cylindrical rollers arranged in an orthogonal (cross) pattern as the rolling elements, significantly reducing friction resistance while satisfying exceptionally high load capacity requirements.

  • Japanese Precision Rollers: Employs precision rollers made in Japan (JIS B 1506 G2 grade) to ensure superior roundness, smooth rolling, and excellent wear resistance.
  • Stainless Steel Construction: The V-groove rails are entirely crafted from high-grade stainless steel for outstanding corrosion resistance.
  • High Load Capacity: The rigid rail structure and cross-roller configuration provide uniform load distribution in all directions, making it highly suitable for heavy-duty applications.
  • Typical Applications: Widely used in optical measuring instruments, PCB drilling machines, X-ray equipment, precision positioning stages, and semiconductor manufacturing.

Technical Notes

Stroke Calculation: Because it is a non-circulating type, when the rail moves, the roller cage moves half the distance in the same direction. Therefore, the maximum stroke is strictly determined by the rail length relative to the cage length.

Lubrication: Rails are factory pre-lubricated with high-quality Lithium Soap Grease. Periodic re-lubrication is highly recommended to maintain smooth operation and extend service life.

Cage Shift Phenomenon: In high-speed, vertical, or uneven load applications, "cage shift" (cage creeping) may gradually occur. It is recommended to perform a full stroke cycle periodically to mechanically re-center the cage.

Complete Set Ordering Code

Example: LGC 3 A 200 R25 - H
No. Item Options & Description
1 Series Code LGC: Cross Roller Guide
2 Roller Diameter 1: Φ1.5mm  |  2: Φ2.0mm  |  3: Φ3.0mm
4: Φ4.0mm  |  6: Φ6.0mm
3 Assembly Type A: 3-Rail Type (1 Main + 2 Sub)
B: 4-Rail Type (2 Main + 2 Sub)
4 Rail Length Total length in mm (e.g., 200).
Note: For Type A (3-Rail), if the main and sub rails have different lengths, specify as Main x Sub (e.g., 200X100).
5 Roller Quantity R25: Represents 25 Rollers inside the cage.
(Refer to the detailed dimension catalog for standard quantities corresponding to rail lengths).
6 Accuracy Grade H: High Grade
P: Precision Grade
Special Note: The LGC6 model is available in the B (4-Rail type) configuration only.

Component Ordering (Cage Assembly Only)

Example: LGC 3 R25
No. Item Options & Description
1 Series Code LGC: Cross Roller Guide Component
2 Roller Diameter 1: Φ1.5mm  |  2: Φ2.0mm  |  3: Φ3.0mm
4: Φ4.0mm  |  6: Φ6.0mm
3 Roller Quantity R25: Represents a cage assembly containing exactly 25 rollers.

Installation & Adjustment Specifications

1. Mounting Bolt Torque

Model Size Bolt Spec Tightening Torque (N.m)
LGC1 M1.4 x 0.3 0.14
LGC2 M2.0 x 0.4 0.40
LGC3 M3.0 x 0.5 1.40
LGC4 M4.0 x 0.7 3.20
LGC6 M5.0 x 0.8 6.60

2. Adjustment Screw (For Preload)

Model Size Screw Spec Max Torque (N.m)
LGC1 M2 0.008
LGC2 M3 0.012
LGC3 M4 0.050
LGC4 M4 0.080
LGC6 M5 0.200

3. Allowable Preload (μm)

Warning: Applying excessive preload will drastically shorten the operational life of the guide. Please strictly refer to the table below for the maximum allowable compression:
Specification LGC1 LGC2 LGC3 LGC4
Allowable Preload (Compression) -2 μm -3 μm -4 μm -5 μm
  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B600R45-P

    Specifications: LGC6B600R45-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 600 Nominal rail length 600 mm R45 45 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 45 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 396 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 4464 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 600 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 11 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R45. This set uses two cages with 45 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 600 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 600 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 114750 N and allowable load Fa0 = R × F0 = 36450 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 600 mm³ × 0.008 g/mm³; rounded upward to 4464 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,502.48

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B600R40-P

    Specifications: LGC6B600R40-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 600 Nominal rail length 600 mm R40 40 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 40 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 486 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 4464 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 600 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 11 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R40. This set uses two cages with 40 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 600 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 600 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 102000 N and allowable load Fa0 = R × F0 = 32400 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 600 mm³ × 0.008 g/mm³; rounded upward to 4464 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,476.04

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B550R45-P

    Specifications: LGC6B550R45-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 550 Nominal rail length 550 mm R45 45 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 45 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 296 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 4092 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 550 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 10 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R45. This set uses two cages with 45 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 550 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 550 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 114750 N and allowable load Fa0 = R × F0 = 36450 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 550 mm³ × 0.008 g/mm³; rounded upward to 4092 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,385.62

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B550R40-P

    Specifications: LGC6B550R40-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 550 Nominal rail length 550 mm R40 40 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 40 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 386 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 4092 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 550 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 10 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R40. This set uses two cages with 40 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 550 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 550 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 102000 N and allowable load Fa0 = R × F0 = 32400 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 550 mm³ × 0.008 g/mm³; rounded upward to 4092 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,358.63

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B550R36-P

    Specifications: LGC6B550R36-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 550 Nominal rail length 550 mm R36 36 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 36 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 458 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 4092 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 550 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 10 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R36. This set uses two cages with 36 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 550 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 550 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 91800 N and allowable load Fa0 = R × F0 = 29160 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 550 mm³ × 0.008 g/mm³; rounded upward to 4092 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,337.39

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B500R45-P

    Specifications: LGC6B500R45-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 500 Nominal rail length 500 mm R45 45 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 45 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 196 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 3720 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 500 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 9 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R45. This set uses two cages with 45 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 500 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 500 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 114750 N and allowable load Fa0 = R × F0 = 36450 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 500 mm³ × 0.008 g/mm³; rounded upward to 3720 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,268.21

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B500R40-P

    Specifications: LGC6B500R40-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 500 Nominal rail length 500 mm R40 40 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 40 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 286 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 3720 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 500 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 9 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R40. This set uses two cages with 40 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 500 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 500 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 102000 N and allowable load Fa0 = R × F0 = 32400 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 500 mm³ × 0.008 g/mm³; rounded upward to 3720 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,241.22

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B500R36-P

    Specifications: LGC6B500R36-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 500 Nominal rail length 500 mm R36 36 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 36 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 358 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 3720 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 500 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 9 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R36. This set uses two cages with 36 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 500 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 500 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 91800 N and allowable load Fa0 = R × F0 = 29160 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 500 mm³ × 0.008 g/mm³; rounded upward to 3720 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,219.99

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B450R40-P

    Specifications: LGC6B450R40-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 450 Nominal rail length 450 mm R40 40 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 40 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 186 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 3348 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 450 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 8 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R40. This set uses two cages with 40 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 450 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 450 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 102000 N and allowable load Fa0 = R × F0 = 32400 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 450 mm³ × 0.008 g/mm³; rounded upward to 3348 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,123.67

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B450R36-P

    Specifications: LGC6B450R36-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 450 Nominal rail length 450 mm R36 36 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 36 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 258 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 3348 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 450 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 8 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R36. This set uses two cages with 36 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 450 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 450 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 91800 N and allowable load Fa0 = R × F0 = 29160 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 450 mm³ × 0.008 g/mm³; rounded upward to 3348 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,102.58

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B450R32-P

    Specifications: LGC6B450R32-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 450 Nominal rail length 450 mm R32 32 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 32 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 330 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 3348 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 450 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 8 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R32. This set uses two cages with 32 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 450 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 450 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 81600 N and allowable load Fa0 = R × F0 = 25920 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 450 mm³ × 0.008 g/mm³; rounded upward to 3348 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,081.48

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B400R36-P

    Specifications: LGC6B400R36-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 400 Nominal rail length 400 mm R36 36 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 36 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 158 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 2976 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 400 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 7 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R36. This set uses two cages with 36 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 400 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 400 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 91800 N and allowable load Fa0 = R × F0 = 29160 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 400 mm³ × 0.008 g/mm³; rounded upward to 2976 g. Verify the packed weight if the shipment requires an exact transport mass.

    $985.17

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B400R32-P

    Specifications: LGC6B400R32-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 400 Nominal rail length 400 mm R32 32 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 32 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 230 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 2976 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 400 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 7 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R32. This set uses two cages with 32 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 400 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 400 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 81600 N and allowable load Fa0 = R × F0 = 25920 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 400 mm³ × 0.008 g/mm³; rounded upward to 2976 g. Verify the packed weight if the shipment requires an exact transport mass.

    $962.84

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B400R28-P

    Specifications: LGC6B400R28-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 400 Nominal rail length 400 mm R28 28 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 28 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 302 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 2976 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 400 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 7 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R28. This set uses two cages with 28 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 400 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 400 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 71400 N and allowable load Fa0 = R × F0 = 22680 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 400 mm³ × 0.008 g/mm³; rounded upward to 2976 g. Verify the packed weight if the shipment requires an exact transport mass.

    $945.30

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B350R32-P

    Specifications: LGC6B350R32-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 350 Nominal rail length 350 mm R32 32 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 32 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 130 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 2604 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 350 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 6 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R32. This set uses two cages with 32 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 350 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 350 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 81600 N and allowable load Fa0 = R × F0 = 25920 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 350 mm³ × 0.008 g/mm³; rounded upward to 2604 g. Verify the packed weight if the shipment requires an exact transport mass.

    $901.19

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B350R28-P

    Specifications: LGC6B350R28-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 350 Nominal rail length 350 mm R28 28 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 28 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 202 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 2604 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 350 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 6 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R28. This set uses two cages with 28 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 350 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 350 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 71400 N and allowable load Fa0 = R × F0 = 22680 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 350 mm³ × 0.008 g/mm³; rounded upward to 2604 g. Verify the packed weight if the shipment requires an exact transport mass.

    $1,173.68

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B350R25-P

    Specifications: LGC6B350R25-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 350 Nominal rail length 350 mm R25 25 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 25 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 256 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 2604 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 350 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 6 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R25. This set uses two cages with 25 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 350 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 350 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 63750 N and allowable load Fa0 = R × F0 = 20250 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 350 mm³ × 0.008 g/mm³; rounded upward to 2604 g. Verify the packed weight if the shipment requires an exact transport mass.

    $864.20

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B300R28-P

    Specifications: LGC6B300R28-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 300 Nominal rail length 300 mm R28 28 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 28 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 102 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 2232 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 300 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 5 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R28. This set uses two cages with 28 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 300 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 300 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 71400 N and allowable load Fa0 = R × F0 = 22680 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 300 mm³ × 0.008 g/mm³; rounded upward to 2232 g. Verify the packed weight if the shipment requires an exact transport mass.

    $816.11

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B300R25-P

    Specifications: LGC6B300R25-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 300 Nominal rail length 300 mm R25 25 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 25 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 156 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 2232 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 300 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 5 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R25. This set uses two cages with 25 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 300 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 300 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 63750 N and allowable load Fa0 = R × F0 = 20250 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 300 mm³ × 0.008 g/mm³; rounded upward to 2232 g. Verify the packed weight if the shipment requires an exact transport mass.

    $800.77

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B300R22-P

    Specifications: LGC6B300R22-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 300 Nominal rail length 300 mm R22 22 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 22 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 210 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 2232 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 300 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 5 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R22. This set uses two cages with 22 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 300 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 300 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 56100 N and allowable load Fa0 = R × F0 = 17820 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 300 mm³ × 0.008 g/mm³; rounded upward to 2232 g. Verify the packed weight if the shipment requires an exact transport mass.

    $785.01

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B250R25-P

    Specifications: LGC6B250R25-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 250 Nominal rail length 250 mm R25 25 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 25 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 56 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 1860 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 250 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 4 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R25. This set uses two cages with 25 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 250 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 250 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 63750 N and allowable load Fa0 = R × F0 = 20250 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 250 mm³ × 0.008 g/mm³; rounded upward to 1860 g. Verify the packed weight if the shipment requires an exact transport mass.

    $737.33

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B250R22-P

    Specifications: LGC6B250R22-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 250 Nominal rail length 250 mm R22 22 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 22 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 110 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 1860 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 250 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 4 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R22. This set uses two cages with 22 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 250 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 250 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 56100 N and allowable load Fa0 = R × F0 = 17820 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 250 mm³ × 0.008 g/mm³; rounded upward to 1860 g. Verify the packed weight if the shipment requires an exact transport mass.

    $721.58

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B250R19-P

    Specifications: LGC6B250R19-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 250 Nominal rail length 250 mm R19 19 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 19 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 164 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 1860 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 250 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 4 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R19. This set uses two cages with 19 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 250 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 250 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 48450 N and allowable load Fa0 = R × F0 = 15390 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 250 mm³ × 0.008 g/mm³; rounded upward to 1860 g. Verify the packed weight if the shipment requires an exact transport mass.

    $705.69

  • Airtac LGC Series: Cross Roller Guide - LGC1B60R16-H

    Airtac LGC series: crossed-roller guide set - LGC6B200R19-P

    Specifications: LGC6B200R19-P — AirTAC crossed-roller guide set Product Catalog Download Airtac Product Catalog (PDF) For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Model Code Explained Code Meaning LGC Crossed-roller linear guide 6 Size 6; roller diameter 6 mm B Four-row rail arrangement 200 Nominal rail length 200 mm R19 19 rollers per cage P Precision accuracy Technical Specifications Parameter Details Series / size LGC6 Roller diameter 6 mm Rollers per cage 19 Roller pitch P 9 mm Per-roller basic dynamic rating C1 3175 N Per-roller basic static rating C0 2550 N Per-roller allowable load F0 810 N Supply configuration 4 side rails + 2 roller cages + corresponding mounting screws Maximum catalog stroke 64 mm; reserve travel below this maximum Height H tolerance ±0.01 mm Height variation ΔH 0.005 mm Width W tolerance ±0.01 mm Reference weight for this listing 1488 g; estimated for shipping data, not catalog net weight Features and Operation Crossed rollers provide rigidity and accuracy in a finite-travel guide; the catalog specifies JIS B1506 G2 rollers. Roller count, rail length, guide layout, load direction and preload must be selected together. Per-roller ratings are not a complete assembly dynamic rating. External and Mounting Dimensions Dimensions are in millimetres unless another unit is shown. Letter symbols follow the catalog drawing; do not substitute a drawing thread for a mounting screw. Drawing / item Value A 200 B 31 C 15 ΦDA 9 ΦDB 5.3 E 50 F 25 G 14.7 H 6 J M6X1 K 5.2 S 3 n × E 3 × 50 For detailed product dimensions and mounting drawings, please download and refer to the PDF catalog. Compatible Parts and Assembly The matched replacement cage is LGC6R19. This set uses two cages with 19 rollers in each. A separately ordered cage is a replacement accessory; it is not the complete guide set. Use LGC6 rails for the selected B arrangement and 200 mm rail length. Equal roller diameter alone does not establish compatibility with another guide family. For a mixed-length rail assembly, use the shorter rail to select roller count and maximum stroke. This model specifies equal 200 mm nominal rails. Installation, Lubrication and Use The rollers alternate at right angles in a non-recirculating cage. Cage travel is one half of table travel; the maximum usable travel depends on the shortest rail and roller count. Reserve travel below the catalog maximum stroke. High acceleration, unbalanced loading, vertical mounting and vibration can make a cage drift; periodically traverse the full intended stroke to re-centre it. The factory adjusts the guide as a set. Interchanging rails or cages between sets does not guarantee the original accuracy; inspect and readjust clearance after replacement. Remove storage anti-rust oil and apply a lubricant suitable for the environment. Do not mix incompatible lubricants; cycle the guide to distribute lubricant and remove excess. Keep mounting surfaces clean and accurate. Secure the datum rails, insert cages and mating rails, temporarily assemble the table, centre the cages and measure travel before final tightening. Adjust clearance only within the roller contact range, repeatedly checking the table with a gauge until the movement is stable. A pressure plate or wedge arrangement can increase mounting rigidity. Lubrication and inspection intervals depend on the operating conditions. The catalog does not give one fixed replenishment interval or a continuous-use temperature rating for every LGC model. Rail mounting screw: M5X0.8PX20L; recommended tightening torque 6.6 N·m. Clearance-adjusting screw: M5; recommended adjustment torque 0.2 N·m. These are separate operations and torques. Load Selection and Service Life For the catalog calculation, the guide static rating Ca0 = R × C0 = 48450 N and allowable load Fa0 = R × F0 = 15390 N. Apply the catalog guide layout and loading diagram; do not multiply these values again by the two cages. The dynamic rating depends on vertical or lateral loading and the effective roller count. Use the catalog equations for the actual arrangement; a cage replacement does not establish a new assembly load rating. Static safety factor fs = Ca0 / F: the catalog recommends 1–1.3 for normal operation and 2–3 where shock is present. Nominal travel life L = [(fT / fw) × (Ca / F)]^(10/3) × 100 km. Life in hours = L × 10^6 / (2 × stroke in mm × cycles per minute × 60). Use the temperature factor fT and service factor fw for the actual conditions. The service-factor examples are fw = 1–1.2 for very small vibration at speed up to 0.25 m/s and fw = 1.2–1.5 for small vibration above 0.25 and up to 1 m/s. The temperature-derating graph above 100°C is a calculation reference, not a continuous operating-temperature rating. Weight Reference Conservative metal-equivalent outer-envelope estimate for the rail set, density assumption 8 g/cm³; openings and running gaps are not deducted. Not an official material specification or measured net mass. Calculation: 2 × 31 × 15 × 200 mm³ × 0.008 g/mm³; rounded upward to 1488 g. Verify the packed weight if the shipment requires an exact transport mass.

    $642.26


You have seen 24 out of 474 products

Footer image

© 2026 Airtac, Powered by Shopify

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • Amazon
  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • USDC
  • Visa